My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
2401
>
2200 - Hazardous Waste Program
>
PR0513702
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2020 11:03:38 AM
Creation date
9/29/2020 10:33:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0513702
PE
2226
FACILITY_ID
FA0009212
FACILITY_NAME
LEPRINO FOODS CO
STREET_NUMBER
2401
STREET_NAME
MACARTHUR
STREET_TYPE
Dr
City
TRACY
Zip
95376
APN
21307050
CURRENT_STATUS
01
SITE_LOCATION
2401 MacArthur Dr
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> COUNTY fM <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address : Date: <br /> LEPRINO FOODS CO 2401 MacArthur Dr, TRACY September 05 , 2018 <br /> Treatment, Transport and Disposal <br /> 208 HSC 25200.3 . 1 (c) Failure of laboratory to comply with hazardous waste treatment requirements ❑ V ❑ R ❑ COS <br /> 209 CCR 66262. 34(d) (2) Failure to remove all hazardous waste from tanks, containers and containment upon facility closure ❑ V ❑ R ❑ COS <br /> Preparedness and Prevention <br /> 301 CCR 66262. 34 (d) (2) Facility not maintained to minimize the release of a hazardous waste ❑ V ❑ R D COS <br /> 302 CCR 66262.34 (d) (2) Failed to maintain required emergency equipment ❑ V ❑ R D COS <br /> 303 CCR 66262.34 (d) (2) Failed to maintain all communication or alarm systems, spill control , or decontamination equipment ❑ V ❑ R ❑ COS <br /> 304 CCR 66262.34 (d) (2) Failed to maintain adequate aisle space for unobstructed response to emergencies ❑ V ❑ R ❑ COS <br /> Container Management <br /> 401 CCR 66262. 34(d) (2) Failed to store hazardous waste in a container that is in good condition ❑ V ❑ R ❑ COS <br /> 402 CCR 66262. 34(d) (2) Failed to store hazardous waste in a compatible container ❑ V ❑ R ❑ COS <br /> 403 CCR 66262. 34(d) (2) Failed to keep hazardous waste containers closed except when adding or removing hazardous waste ❑ V ❑ R ❑ COS <br /> 404 CCR 66262. 34(d) (2) Failed to inspect hazardous waste storage areas at least weekly ❑ V ❑ R ❑ COS <br /> 405 CCR 66262. 34(d) (2) Failed to manage incompatible wastes in containers properly ❑ V ❑ R ❑ COS <br /> 406 CCR 66261 .7 Contaminated container not marked with date emptied or managed within one year of being emptied ❑ V ❑ R ❑ COS <br /> 407 CCR 66262. 34 (e) (1 ) (A) Satellite accumulation container not located near point of generation or under control of operator ❑ V ❑ R ❑ COS <br /> 408 CCR 66262. 34 (e) (2) Satellite accumulation exceeded 55 gallons of HW (or one quart of acutely H " per waste stream ❑ V ❑ R ❑ COS <br /> Tank Management <br /> 501 CCR 66262. 34(d) (2) No overfill prevention device on continuously fed hazardous waste tank ❑ V ❑ R ❑ COS <br /> 502 CCR 66262. 34(d) (2) Tank system inspections of discharge systems, monitoring equipment, and tank levels not done daily ❑ V ❑ R ❑ COS <br /> 503 CCR 66262. 34(d) (2) Tank system inspections of construction materials, fixtures, and surrounding areas not done weekly ❑ V ❑ R ❑ COS <br /> 504 CCR 66262. 34(d) (2) Failed to maintain at least two feet of freeboard in uncovered tank with no secondary containment ❑ V ❑ R ❑ COS <br /> 505 CCR 66262. 34 (f) Failed to completely label stationary hazardous waste tanks ❑ V ❑ R D COS <br /> Labeling and Storage <br /> 601 CCR 66262. 34(d) Stored hazardous waste onsite greater than 180 days ❑ V ❑ R ❑ COS <br /> 602 CCR 66262. 34(e) (1 ) (B) Stored satellite accumulated waste on site longer than one year or 180 days after fill date ❑ V D R ❑ COS <br /> 603 CCR 66262. 34(e) (1 ) (C) Failed to mark initial accumulation start date on satellite containers D V ❑ R ❑ COS <br /> 604 CCR 66262. 34(e) (3) Failed to mark satellite containers with date filled within three days ❑ V ❑ R ❑ COS <br /> 605 CCR 66262. 34(f) Failed to completely label containers or portable tanks of hazardous waste ■ V ■ R ❑ COS <br /> 606 CCR 66266, 81 (a) (3) Failed to meet lead acid battery storage requirements for hazardous waste management exemption ❑ V ❑ R ❑ COS <br /> 607 CCR 66266, 81 (b) Damaged lead acid batteries not properly managed and labeled ❑ V ❑ R ❑ COS <br /> 608 CCR 66266. 130 Failed to properly manage used oil and fuel filters ❑ V ❑ R ❑ COS <br /> 609 HSC 25143. 23 25143 .9 Failed to meet requirements for claimed excluded recyclable materials ❑ V ❑ R ❑ COS <br /> 610 CCR 66262. 34(b) (1 ) Stored acutely or extremely hazardous waste onsite greater than 90 days ❑ V D R ❑ COS <br /> 611 HSC 25200. 3 . 1 (b) Failure of laboratory to comply with hazardous waste accumulation area requirements ❑ V ❑ R ❑ COS <br /> FA0009212 PR0513702 SCO01 09/05/2018 <br /> EHD 22-01 Rev. 10/31 /2017 Page 2 of 5 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464-0138 I www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.