My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
10998
>
2200 - Hazardous Waste Program
>
PR0514366
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/1/2020 3:53:43 PM
Creation date
9/30/2020 4:03:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514366
PE
2228
FACILITY_ID
FA0010523
FACILITY_NAME
Papé Trucks, Inc.
STREET_NUMBER
10998
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
Rd
City
French Camp
Zip
95231
APN
193-330-30
CURRENT_STATUS
01
SITE_LOCATION
10998 S Harlan Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
582
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
including the quantity of waste removed, the sump (3) Each container and portable tank in which <br /> or collection system and the date and time of removal. hazardous waste is accumulated must be labeled with <br /> If hazardous waste is accumulated in containment the following information: <br /> buildings,the generator must comply with Title 22, (a) composition and physical state of the waste; <br /> Cal. Code Regs., division 4.5, chapter 15,article 29 (b) statement or statements that call attention <br /> (Containment Buildings), and obtain a professional to the particular hazardous properties of the waste <br /> engineer certification that the building complies with (e.g. flammable,reactive); and <br /> the design standards specified in Section 66265.1101. (c) name and address of the generator. (Section <br /> The engineer certification is required prior to 66262.34.) <br /> operating the unit and must be placed in the facility's <br /> operating record. (Section 66262.34 (a)(1)(C)). (4) Containers and tanks used by the generator to <br /> collect or consolidate wastes initially accumulated in <br /> (7) The owner or operator of a containment building other containers or tanks are subject to the same <br /> must maintain the following records at the facility: labeling requirements.The initial accumulation and <br /> (a) a written description of procedures to ensure "90-day period" dates on the "collection" container/ <br /> that each waste volume remains in the unit for no tank must be the oldest of the initial accumulation <br /> more than 90 days,a written description of the waste and "90-day period" dates from the various <br /> generation and facility management practices showing containers/tanks emptied into the "collection" <br /> that they are consistent with the 90 day limit, and container/tank.This may require dates to be changed <br /> documentation that the procedures are complied with if wastes from"older" containers/tanks are added to <br /> (Section 66262.34 (a)(1)(C)(1));or the "collection"container/tank. <br /> (b) documentation that the unit is emptied at <br /> least once every 90 days. (Section 66262.34 (5) In some cases,containers are continuously reused <br /> (a)(1)(C)(2)). for accumulation of the same waste stream; e.g., <br /> drums used to initially accumulate waste which when <br /> (8) A generator accumulating in tanks or containers full are emptied into larger "collection" containers. <br /> is exempt from articles 7 and 8 in Title 22, Cal.Code "Recurring use"labels may be used on such contain- <br /> Regs., division 4.5, chapter 15, except Sections ers to revise the initial accumulation and "90-day <br /> 66265.111 (Closure Performance Standards) and period" dates (without having to change the other <br /> 66265.114 (Decontamination). (Section 66262.34 labeling information).If the container is emptied at <br /> (a)(1)). least once each day,the word "daily" may be used in <br /> For a more detailed explanation on accumulation the date area of the label. <br /> requirements, read DTSC's "Accumulating <br /> Hazardous Wastes at Generator Sites" Fact Sheet E. EMERGENCY PROCEDURES/ <br /> (January 2002). CONTINGENCY PLANS <br /> D. LABELING/MARKING (1) ALL GENERATORS <br /> All generators must comply with these requirements <br /> (1) The date upon which each period of accumulation regarding preparedness and prevention: <br /> begins must be clearly marked and visible for (a) All operations must minimize the possibility <br /> inspection on each accumulation unit. (Section of a fire, explosion or any unplanned release of <br /> 66262.34.) hazardous waste or hazardous waste constituents to <br /> air, soil,or surface water that could threaten human <br /> (2) While being accumulated on site,each generator health or the environment. (40 C.F.R.section 265.3 1, <br /> tank or container must be labeled or clearly marked Section 66265.31) <br /> with the words, "Hazardous Waste." (Section (b) A generator's site must be equipped with the <br /> 66262.34.) following, unless it can be demonstrated to DTSC <br />
The URL can be used to link to this page
Your browser does not support the video tag.