COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2020 4:29:03 PM
Creation date
10/8/2020 7:37:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM <br /> Type of Action: ❑Installation Inspection ❑Repair Inspection N 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment <br /> Inspection 11/15/2018 <br /> Business Name George Kishida Trucking <br /> Business Site Address 1725 Ackerman Dr. City Lodi Zip Code <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Service Technician(on ICC Certification) Rhome Desbiens Phone# 916-371-2380 <br /> Contractor License#: 433159 ICC Certification: 5244364 ICC Expiration Date: 1/5/2019 <br /> Overfill Prevention Equipment Relevant Certifications(List Applicable): <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑Manufacturer Guidelines(Specify): <br /> Used: <br /> ®Industry Code or Engineering Standard(Specify): <br /> ❑Engineered Method(Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of attached pages <br /> Tank ID:(By tank number,stored DSL-1 DSL-2 <br /> What is the tank inside diameter?(inches) 90.5" 90.5" <br /> Is the Fill Piping Secondarily contained? ❑Yes N No ❑Yes N No ❑Yes ❑No ❑Yes ❑No <br /> Is the Vent Piping Secondarily contained? ❑Yes N No ❑Yes N No ❑Yes ❑No ❑Yes <br /> ❑No <br /> Overfill Prevention Equipment OPW OPW <br /> Manufacturer <br /> Tank Manufacturer Flapper Flapper <br /> What is the overfill prevention equipment ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> response when activated? N Restricts Flow N Restricts Flow ❑Restricts Flow ❑Restricts Flow <br /> (Check all that apply) ❑A/V Alarm ❑A/V Alarm ❑A/V Alarm ❑A/V Alarm <br /> Are flow restrictors installed on vent ❑Yes N No ❑Yes N No ❑Yes ❑No <br /> El Yes ❑No <br /> piping? <br /> At what level in the tank is the overfill <br /> prevention set to activate?(Inches from 81" 77" <br /> bottom of tank.) <br /> What is the percent capacity of the tank at <br /> which the overfill prevention equipment 92% 85% <br /> activates? <br /> Is the overfill prevention in proper ®Yes ®Yes ❑Yes ❑Yes <br /> operating condition to respond when theeci <br /> ElNo(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) <br /> substance reaches the appropriate level? <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results N Pass ❑Fail N Pass ElFail ❑Pass ❑Fail ❑Pass ❑Fail <br /> V. COMMENTS <br /> Any items marked"Fail"must be explained in this section.Any additional comments may also be provided here. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained he:eiii is accurate <br /> UST Service Technician Signature <br />
The URL can be used to link to this page
Your browser does not support the video tag.