Laserfiche WebLink
` LEAK SENSOR 7 LEAK SENSOR 19 <br /> \` ENABLED DISABLED <br /> COpy TANK: 1 N / <br /> AkE Alarm relay #: 2 Alarm relay #: 0 <br /> Leak test E/D: E Leak test E/D: D <br /> SUMP N.C. Sensor <br /> N.C. Sensor <br /> LEAK SENSOR 8 LEAK SENSOR 20 <br /> SITE INFORMATION: DISABLED <br /> KISHIDA DISABLED TANK: 1 <br /> TANK: 1 Alarm relay 4: 0 <br /> Alarm relay #: 0 Leak test E/D: D <br /> VLD TEST DWELL: Leak test E/D: D N.C. Sensor <br /> 30 N.C. Sensor <br /> DROP REPORT DWELL: LEAK SENSOR 9 LEAK SENSOR 21 <br /> DISABLED <br /> 5 DISABLED <br /> TANK: 1 <br /> TANK: 1 <br /> Alarm relay #: 0 <br /> DROP REPORT THRESH: Alarm relay #: 0 Leak test E/D: D <br /> 100 Leak test E/D: D N.C. Sensor <br /> N.C. Sensor _ <br /> VLD TEST TIME: LEAK SENSOR 22 <br /> 4 LEAK SENSOR 10 DISABLED <br /> DISABLED TANK: 1 <br /> SITE MANAGER: TANK: 1 Alarm relay #: 0 <br /> PHONE: Alarm relay #: 0 Leak test E/D: D <br /> Leak test E/D: D N.C. Sensor <br /> IDENTIFICATION #: N.C. Sensor <br /> LEAK SENSOR 11 LEAK SENSOR 23 <br /> DISABLED <br /> DISABLED <br /> TANK: 1 <br /> TANK: 1 Alarm relay tt: 0 <br /> Alarm relay #: 0 Leak test E/D: D <br /> Leak test E/D: D N.C. Sensor <br /> N.C. Sensor <br /> LEAK SENSOR 12 LEAK SENSOR 24 <br /> DISABLED <br /> DISABLED <br /> TANK: 1 <br /> Leak Sensor Parameters TANK: 1 Alarm relay #: 0 <br /> Alarm relay tt: p Leak test E/D: D <br /> LEAK SENSOR 1 Leak test E/D: D N.C. Sensor <br /> ENABLED N.C. Sensor Tank 2 Setup <br /> TANK: 1 Relay Code:Disabled <br /> Alarm relay tt; p LEAK SENSOR 13 Alarm Relay #:Disabled <br /> DISABLED Tank Type: Fiberglass <br /> Leak test EiD: E <br /> Leakest TANK: 1 Product Type: DIESEL <br /> DOUBN.C. Sensor Alarm relay #: 0 Thermal : 45x10**-5 <br /> Leak test E/D: D Probe Length: 100 in. <br /> LEAK SENSOR 2 N.C. Sensor Tank Tilt : 0 in. <br /> Wire :DISABLED LEAK SENSOR 14 WaterSNuldl : .9 <br /> .DISABLED <br /> TANK: 1 DISABLED Product Null : 1 .0 in. <br /> Alarm relay tt: p TANK: 1 Hi Water Alarm; 3 in. <br /> Leak test E/D: D Alarm relay #: 0 Low Alarm: 15 % <br /> N.C. Sensor Leak test E/D: D High Warn: 85 % <br /> LEAK SENSOR 3 N.C. Sensor High Alarm: 90 % <br /> ENABLED Tank Capacity: 3219 Gal . <br /> LEAK SENSOR 15 <br /> TANK: 1 Tank Diameter : 89.75 in. <br /> Alarm relay #: 1 DISABLED Tank Length: in. <br /> Leak test E!D: E TANK: 1 Tank Offset : 0 Ga I . <br /> SUMP Alarm relay #: 0 VLD Date: 15 <br /> N.C. Sensor Leak test E/D: D VLD Dav, 1-7.Sun-Sat : <br /> N.C. Sensor VLD Time U#-UU: 01 .00 <br /> LEAK SENSOR 4 VLD Interval ,D/W/M: M <br /> DISABLED LEAK SENSOR 16 Auto VLD E/D: D <br /> TANK: 1 DISABLED Tank Number : 2 <br /> Alarm relay 9: p TANK: 1 Tank Table Length: 20 <br /> Leak test E/D: D Alarm relay #: 0 5.00 % vol .=46 gal . <br /> N.C. Sensor Leak test E/D: D 10.00 % vol .=134 gal . <br /> N.C. Sensor 15.00 % vol .=255 gal . <br /> LEAK SENSOR 520.00 % vol .=402 ga-l . <br /> DISABLED LEAK SENSOR 17 25.00 % vol .=572 gal . <br /> TANK: 1 DISABLED 30.00 % vol .=754 gal . <br /> TANK: 1 35.00 % vol .=949 gal . <br /> Alarm relay #: 0 Alarm relay #: 0 40.00 % vol -1166 sal . <br /> Leak test E/D: D Leak test E/D: D 45.00 % vol .=1385 gal . <br /> N.C. Sensor N.C. Sensor 50.00 % vol .=1507 sal <br /> LEAK SENSOR 6 55,00 % vol .=1892 gal . <br /> DLEAK SENSOR 18 60.00 % vol .=2048 sal . <br /> DISABLED <br /> TANK: 1 DISABLED 65.00 � vol =2259 gal <br /> TANK: 1 70.00 % vo•l .=2461 gal <br /> Alarm relay #: 0 Alarm relay #: 0 75.00 % vol .=2643 gal . <br /> Leak test E/D: D Leak test E/D: D 80.00 % vol .=2813 gal <br /> N.C. Sensor N.C. Sensor 85.00 % vol .=2961 gal . <br /> 90.00 % vol .=3083 gal . <br />