Laserfiche WebLink
SA N ,J DA Q N IN Environmental Health Department <br /> " COUNTY <br /> `" ''''` Percolation Test Procedure <br /> The San Joaquin County Environmental Health Department (EHD) has adopted the following procedure in order to evaluate and process percolation <br /> results uniformly, effectively and quickly. <br /> Obtain Application for Percolation Test Permit: <br /> • Fee is$152 per test hole or$760 for 5 or more test holes. <br /> • Indicate the test hole location(s)on the permit application plot plan. <br /> • Percolation Test Hole(s)shall not be located within 100 feet of any well or violation any other set-back requirements for a septic system. <br /> • Call (209)953-7697 to schedule an inspection 48 hours in advance. <br /> Preparation of Test Hole(s) Preparation of Test Hole(s) for Deep Perc Test: <br /> Test Ho/e(s) dimensions: Test Hole Dimensions: <br /> Diameter=4 inches to 12 inches Diameter=4 inches to 12 inches <br /> Depth(Consistent with leach field) =36-42' Depth=42 inches to 25 feet, Minimum 10 feet above water table. <br /> •. Scratch or score sides to remove any smeared soil surfaces. a Pre-soak Test Hole(s)by adding water 6"above selected stratum. <br /> • Remove loose material from hole. 9 Maximum water level allowed=3 feet above selected stratum <br /> • Add 2 inches of course sand or fine gravel. 0 Red Zone area requires 25'deep test hole(s)or soil stratum that meets <br /> • Saturation: Pre-soak Test Hole(s)24 hours before test by adding water a minimum percolation rate for pit testing. <br /> minimum of 12 inches over gravel. The EHD is to be notified of start of <br /> Percolation Test. <br /> PROCEDURE#1 PROCEDURE#2 PROCEDURE#3 <br /> If water remains in the test hole overnight If NO water remains in test h ole overnight Sandy soils (or other soils)in which the first 6 <br /> • Add clear water to approximately 6 inches inches of water seeps away in less than thirty(30) <br /> over the gravel. Add clear water to bring depth of water in the hole to minutes after the overnight saturation period <br /> • From a fixed reference point, measure the approximately 6 inches over the gravel. <br /> drop in water level over a thirty(30)minute 0From a fixed reference point, measure the drop in 0 Refill the hole to approximately 6 inches above <br /> period. water level at thirty(30)minute intervals for four the gravel. <br /> • Calculate the percolation rate in minutes per 4 hours, refilling 6 inches over the gravel as 0 From a fixed reference point,take the readings <br /> inch. necessary. 10 minutes apart over a one (1)hour period. <br /> • Use the smallest reading of the four(4)hour 0 Use the smallest reading change; calculate <br /> period to calculate percolation rate in minutes per percolation rate in minutes per inch. <br /> inch. <br /> At the time of the percolation test inspection, Environmental Health Staff will: <br /> • Review application and parcel map for location accuracy and verify appropriate procedure used. <br /> • Inspect test hole construction and review raw field data recorded prior to arrival. <br /> • Observe and document the readings during the final 30 minutes of the test on the EHD"Percolation Test Application." <br /> • Correct any data on the application and sign the percolation record sheets. <br /> Source: Manual of Septic Tank Practices,U.S.Dept.of H.E.W.(1967),as founded and modified for San Joaquin County. <br /> San Joaquin County EHD Policy#98-02. <br /> EHD 42-01-002 Revised 4/14/2018 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />