1._7.. EMERGENCY SWITCH PARTS AND SIGN <br />SUPPLIED BY 7 -ELEVEN, INC. AND <br />VERTICAL SEALING INSTALLED BY GAS CONTRACTOR <br />c <br />RIGID CONDUIT <br />.n <br />EYS CONDUIT <br />MagVFC SEALING COMPOUND USE COMPOUNDSEAL FITTING (XP) <br />°1 <br />MADE BY MANUFACTURER OF SEAL SIGN <br />FITTING <br />0 0 0 0 0 0 0 0 0 <br />(WHITE RED EMERGENCY <br />LETTERING) SHUT OFF G' <br />PUSH CONDUCTORS AWAY FROM THE FILLING S W ITCH <br />OPENING & FORCE THEM APART SO THEY DOApgCKED FIBER 0 <br />YLl NOT LIE IN CONTACT WITH EACH OTHER ALONGDAM COVER = <br />THEIR LENGTH PUSH SHREDS OF PACKING <br />AWAY FROM THE CONDUCTOR TO PREVENT (SAFETY TECHNOLOGY <br />GAS LEAKAGE PATHS INTERNATIONAL, INC. qk <br />v <br />NOTE: <br />Proto 11-05-18 <br />LARGE MUSHROOM HEAD Z <br />PROVIDE EXPLOSION PROOF SEALS. IN ACCORDANCE WITH ARTICLE 501, CLASS 1, EMERGENCY STOP BUTTON <br />DIVISION 2 OF THE LATEST NATIONAL ELECTRICAL CODE TYPICAL FOR ALL (CONTACT ACTUATOR) <br />UNDERGROUND CONDUIT STUB -UPS INTO EQUIPMENT LIFT <br />p rc <br />rO <br />Y <br />SEAL OFF ALL CONDUIT ENTERING OR LEAVING CAVITIES OR ENCLOSURES OF <br />DISPENSERS AND ASSOCIATED EQUIPMENT. IN ADDITION, ALL CONDUITS COMING <br />FRONT VIEW SIDE VIEW w p <br />FROM THE BUILDING THROUGH A HAZARDOUS LOCATION ALSO REQUIRE J ❑ SEAL -OFFS AT BOTH ENDS. y n <br />o U <br />FE PETRO MAGVFC -VARIABLE 00 X <br />ti <br />FREQUENCY CONTROLLER. SEE MANUAL U F N <br />FOR WIRING INSTRUCTIONS. Z Z r ¢ W <br />3rn LU <br />Z� OU W� <br />W oz Z Z) Q <br />(1A GVFC DETAIL �� SEAL FITTING INSTALLATION �1 EMERGENCY SHUT OFF W� COVER >0 w3:0F ow <br />NTS J NTS L NTS W it > Z Y Z❑ <br />W w Jam° <br />P4. Y LLl U <br />� 0 <br />x g <br />0 <br />M <br />y <br />EMT CONDUIT a <br />O SIZE AND QUANTITY OF 7.N.7UlT7] <br />ARE FOR REFERENCE O <br />W <br />O <br />STORE CONTRACTOR: <br />INSTALL CONDUIT FROM THE ELECTRICAL <br />ROOM TO 10'-0" PAST BUILDING SLAB. SEE <br />SPECIFICATION SHEET G16.0, SECTION VII, <br />2.3.1 FOR CONDUIT TYPES. <br />FUELING CONTRACTOR: <br />EXTEND CONDUITS FROM 10'-0" PAST THE <br />BUILDING SLAB TO FINAL TERMINATION <br />POINT . SEE SPECIFICATION SHEET G16.0, <br />SECTION VII, 2.3.1 FOR CONDUIT TYPES. <br />REF STORE STORE <br />E1.1 SHEET <br />FOR PANEL PANEL <br />INFORMATION <br />WIRE WAY I <br />a <br />ELECTRICAL ROOM CEILING <br />(ACTUAL LAYOUT MAY VARY <br />TO MEET SITE CONDITIONS) <br />I <br />MAG MAG <br />VFC VFC <br />0 0 <br />3 POLE 100 AMP STPCBS o <br />CONTACTOR w <br />0 W F I <br />�0 wO <br />TO SALES <br />WIRE WAY <br />SUPPLIED BY <br />7 -ELEVEN <br />NEW <br />PANEL <br />F <br />DBOX <br />STP 10 <br />IR <br />TVP 3 <br />STP STP <br />IR IR 0 <br />WIRE WAV WIRE WAY WIRE WAY <br />I <br />W K H <br />0 ¢ O O w <br />J w a w z <br />k - y <br />w <br />o > y <br />0 0 <br />O <br />POWER/DATA EQUIPMENT DETAILS <br />� NTS <br />35558 <br />G10.0 <br />FUELING - USA <br />