My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0041064
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CAMPBELL
>
14110
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0041064
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2021 1:48:53 PM
Creation date
10/19/2020 3:10:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0041064
PE
4366
STREET_NUMBER
14110
Direction
S
STREET_NAME
CAMPBELL
STREET_TYPE
AVE
City
ESCALON
Zip
95320-
APN
20731009
ENTERED_DATE
8/6/2020 12:00:00 AM
SITE_LOCATION
14110 S CAMPBELL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Supplemental fields
CYEAR
2020
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
August 6, 2021 Lab ID : STK2139969 <br />San Joaquin Co. Environmental Health Dep Customer : 3-17919 <br />Quality Control - Inorganic <br />Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br />Wet Chem <br />Nitrite 300.0 07/16/21:207998MCA LCS mg/L 15.00 99.2% 90-110 <br />MS mg/L 30.00 102% 74-126 <br />(STK2 139973-001) MSD mg/L 30.00 103% 74-126 <br />MSRPD mg/L 10.00 0.9% <20 <br />300.0 07/16/21:211044MCA CCB mg/L 0.000 0.5 , <br />CCV mg/L 15.00 98.0% 90-110 <br />CCB mg/L 0.000 0.5 <br />CCV mg/L 15.00 97.7% 90-110 <br />Nitrite Nitrogen 300.0 07/16/21:207998MCA Blank mg/L ND <0.2 <br />Sulfate 300.0 07/16/21:207998MCA Blank mg/L ND <0.5 <br />LCS mg/L 50.00 96.8% 90-110 <br />MS mg/L 100.0 97.0% 82-124 <br />(STK2139973-001) MSD mg/L 100.0 98.2% 82-124 <br />MSRPD mg/L 10.00 1.2% 23 <br />300.0 07/16/21:211044MCA CCB mg/L 0.153 0.5 <br />CCV mg/L 50.00 95.2% 90-110 <br />CCB mg/L 0.147 0.5 <br />CCV mg/L 50.00 95.1% 90-110 <br />NIBAS 5540C 07/16/21:210982jba CCB mg/L -0.0310 0.25 <br />CCV mg/L 1.000 97.0% 90-110 <br />CCB mg/L -0.0185 0.25 <br />CCV mg/L 1.000 97.4% 90-110 <br />MBAS Extraction 5540C 07/16/21:208150jba Blank mg/L ND <0.1 <br />LCS mg/L 0.5000 97.0% 86-114 <br />BS mg/L 0.5000 94.7% 86-114 <br />BSD mg/L 0.5000 95.9% 86-114 <br />BSRPD mg/L 0.5000 0.0062 50.1 <br />Definition <br />ICB : Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />CCV : Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />CCB : Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />Blank : Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br />LCS : Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte recovery. <br />MS : Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication of how that sample <br />matrix affects analyte recovery. <br />MSD : Matrix Spike Duplicate of MS/MSD pair - A random sample duplicate is spiked with a known amount of analyte. The recoveries <br />are an indication of how that sample matrix affects analyte recovery. <br />BS : Blank Spikes - A blank is spiked with a known amount of analyte. It is prepared to verify that the preparation process is not <br />affecting analyte recovery. <br />BSD : Blank Spike Duplicate of BS/BSD pair - A blank duplicate is spiked with a known amount of analyte. It is prepared to verify that <br />the preparation process is not affecting analyte recovery. <br />Du p : Duplicate Sample - A random sample with each batch is prepared and analyzed in duplicate. The relative percent difference is an <br />indication of precision for the preparation and analysis. <br />MSRPD : MS/MSD Relative Percent Difference (RPD) - The MS relative percent difference is an indication of precision for the preparation <br />and analysis. <br />BSRPD : BS/BSD Relative Percent Difference (RPD) - The BS relative percent difference is an indication of precision for the preparation <br />and analysis. <br />ND : Non-dctcct - Result was below the DQO listed for the analyte. <br />DQO : Data Quality Objective - This is the criteria against which the quality control data is compared. <br />Page 8 of 8
The URL can be used to link to this page
Your browser does not support the video tag.