My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4900
>
4200 – Liquid Waste Program
>
PR0420087
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:55:59 PM
Creation date
11/24/2020 1:18:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0420087
PE
4242
FACILITY_ID
FA0002643
FACILITY_NAME
STOCKTON VERDE MOBILE HOME PRK
STREET_NUMBER
4900
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08704015
CURRENT_STATUS
01
SITE_LOCATION
4900 N HWY 99
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County Onsite Wastewater Disposal Standards Regional Water Quality Control Board. Any deviation from these discharge <br /> Section 4-Package Treatment Plants requirements shall be declared a public nuisance and a violation of the <br /> 4.1 Where package sewage treatment plants are required, Rules and Regulations of San Joaquin County Ordinance No.3675. As <br /> complete engineered plans shall be submitted by a Registered Civil such, a cease and desist order shall be given. <br /> Engineer to the Director of Environmental Health and the San Joaquin 4.9 Treatment plant tanks are to be installed on undisturbed soil <br /> County Public Works Department for initial approval prior to beginning excavated to required slope and elevation or on properly installed reinforced <br /> construction. Final approval for operation of the package sewage concrete foundation in such a manner as to prevent listing or settling,which <br /> treatment plants shall not be granted until a waste discharge resolution may cause malfunction or leaking. <br /> has been set by the Central Valley Regional Water Quality Control 4.10 A grease receptor shall be required whenever any commercial <br /> Board(CVRWOCB). The plans shall include the following: food establishment is connected to the plant or any activity,which produces <br /> 4.1.1 A complete scaled plot plan of the area showing wells, a grease content over and above the normal grease content found in <br /> structures,sanitary sewerage lines,water lines and total proposed land domestic sewage. Grease receptors shall be required as an addition to a <br /> use. sewage disposal plant if it is determined from the analysis of the sewage <br /> 4.1.2 Total capacity of the plant in gallons and organic load. Design influent or effluent that elevated grease levels prevail. <br /> criteria shall include a reserve capacity to accommodate a surge flow or 4.11 A grease receptor must be installed in front of the wet well(head <br /> increase in the average daily flow. works)to affectively screen out floating and suspended grease produced by <br /> 4.1.3 Calculations showing ability of effluent to meet discharge commercial food operations. The grease receptor must be of sufficient size <br /> standards as set by the Central Valley Regional Water Quality Control to retain the grease-laden sewage for a period suitable to remove the <br /> grease. <br /> Board. <br /> 4.1.4 The source of data and the data calculated to the existing 4.12 An open polishing pond shall be installed between the plant and <br /> plant or any future expansion of the plant shall be shown on the plans. the subsurface disposal field. This pond must be segmented by a series of <br /> redwood baffles and a weir must be installed so as to screen out the <br /> 4.1.5 The percolation rales of leach fields or seepage pits shall be suspended flocculent material remaining prior to flowing into the subsurface <br /> calculated and figures shown on the plans. An expansion area equal in disposal field. <br /> size to the original disposal field shall be so designated on the plan to be 4.13 Monthly monitoring by a certified sewage plant operator is <br /> utilized in the event of failure of the original disposal field. This required. Analysis required may include Biochemical Oxygen Demands, <br /> expansion area shall pertain to percolation ponds or evaporation ponds Dissolved Oxygen and settable solids of plant influents and effluents and at <br /> as well as subsurface disposal fields. such other points on stream as may be necessary*. Average daily flows <br /> 4.1.6 A hydrologic balance for evaporation/percolation ponds. and peak flows after plant is in operation are to be determined by a reliable <br /> 4.2 When any existing package sewage treatment plant is method. Copies of these analyses and operational records shall be <br /> furnished to the Director of Environmental Health and the Central Valley <br /> remodeled or altered,all of the above specifications are to be <br /> Regional Water Quality Control Board. <br /> resubmitted for approval by the Director of Environmental Health and the <br /> CVRWOCB. *Analyses shall be done utilizing the methods specified in the most recent <br /> edition of"Standard Methods for Examination of Water and Wastewater" <br /> 4.3 Mechanical and electrical equipment shall be of such durable USPHS. <br /> hardware,workmanship, and installation as to insure against operational <br /> failure with normal maintenance. 4.14 An auxiliary electrical power supply shall be available for the <br /> continued operation of the package sewage treatment plant. Portable <br /> 4.4 All installations shall be adequately protected against acts of power supply may be used if made available within a reasonable period of <br /> vandalism or sabotage,which could result in a malfunction of the plant. time in the event of a failure. <br /> The entire plant, polishing ponds and percolation ponds shall be fenced <br /> and a locked gate provided to protect against any unauthorized person 4.15 All plumbing fixtures must be of a low flow,energy efficient and <br /> gaining entrance into the plant area,which could lead to injury or loss of water-saver type for commercial facilities. <br /> life. California Health and Safety Code,Section 5411 <br /> 4.5 A certified operator with skill to cause the plant to be operated No person shall discharge sewage,or other waste,or the effluent of treated <br /> as designed shall be available to operate the plant. The operator shall sewage or other waste, in any manner which will result in contamination, <br /> be certified by the State of California Water Resources Control Board- pollution,or a nuisance. <br /> Central Valley Region. <br /> 4.6 All work or works shall be done under applicable required San Joaquin County Ordinance Code,Title 9,Section 9.1110.9 <br /> permits and inspection by the required regulatory agency. It shall be unlawful to maintain or use any residence, place of business,or <br /> other building or place where persons reside,congregate,or are employed <br /> 4.7 The installation and operation of treatment plants shall not which is not provided with a means for the disposal of wastewater which <br /> create a public nuisance in regard to odor nor cause a potential or complies the requirements of this Chapter and the standards relating to <br /> immediate safety or health hazard to the public. The discharge of wastewater disposal established by the Environmental Health Department. <br /> treated effluent shall not cause contamination of the water bearing strata <br /> or surface watercourses. San Joaquin County Ordinance Code,Title 8,Section 5.5100 <br /> 4.8 Final disposition of sewage effluent shall be in constant It is a violation of this division for any property owner to permit or maintain a <br /> compliance with the discharge requirements as set by the Central Valley nuisance on his property. <br />
The URL can be used to link to this page
Your browser does not support the video tag.