Laserfiche WebLink
GENERAL NOTES <br /> I m <br /> 1 . SEE ELECTRICAL SCHEDULE FOR PANEL & CIRCUIT BREAKER <br /> ASSIGNMENT, VOLT/PH, FLA, BREAKER SIZE, COND/WIRE, <br /> RECEPTACLE TYPE, HEIGHT ABOVE FINISHED FLOOR, <br /> REQUIREMENTS & REMARKS FOR ALL ELECTRICAL EQUIPMENT. <br /> 2. VERIFY OEP DROP CORDS DO NOT FALL BELOW HEIGHTS LISTED <br /> ON ELECTRICAL SCHEDULE. RECEPTACLES SHOULD BE LOCATED <br /> AT HEIGHTS TO AVOID CONTACT WITH HOT APPLIANCES. <br /> MATCH LINE <br /> 3. RE-USE EXISTING CIRCUITRY AND BREAKERS. CONFIRM <br /> AMPERAGE AND BREAKER SIZE AS SHOWN ON SCHEDULE. IF <br /> NOT, PROVIDE NEW CIRCUIT BREAKER AND WIRE. o <br /> w <br /> DEMOLITION NOTES � <br /> 4 5 u� <br /> 0 <br /> D1 . THE ELECTRICAL CONTRACTOR SHALL RELOCATE EXISTING <br /> 4 <br /> CATV POWER, DATA, AND TELEPHONE DEVICES IN THE BATHROOM <br /> AREAS TO BE AFFECTED. REFER TO DEMO PLAN D1 .0 FOR w <br /> TYP. AFFECTED AREA. <br /> D2. THE ELECTRICAL CONTRACTOR SHALL RELOCATE EXISTING <br /> NEW DIGITAL MENU BOARD. POWER, DATA, AND TELEPHONE DEVICES FOR THE WALL <br /> REUSE EXISTING CIRCUITRY RELOCATION. REFER TO DEMO PLAN D1 .0 FOR AFFECTED <br /> AND CONTROL. REFER TO AREA. <br /> DIGITAL MENU BOARD DETAIL 13 <br /> ON SHEET E4.0. D3. RE-USE EXISTING CIRCUITRY AND BREAKERS. CONFIRM <br /> l o AMPERAGE AND BREAKER SIZE AS SHOWN ON SCHEDULE. IF <br /> I I NOT, PROVIDE NEW CIRCUIT BREAKER AND WIRE. <br /> LL] <br /> A. <br /> 10 KEY NOTES <br /> 10 12 l ❑ PROVIDE POWER WITHIN CEILING FOR CONNECTION TO SELF ORDER <br /> 1 KIOSKS. COORDINATE EXACT LOCATION OF KIOSKS WITH DECOR w <br /> I DRAWINGS. PROVIDE 2#12,1 #12 GRD., & 1 #12 ISOLATED GROUND ON w <br /> A 20A DEDICATED CIRCUIT FED FROM THE CP PANEL FOR EVERY ONE <br /> (1) DOUBLE SIDED OR TWO (2) SINGLE SIDED KIOSKS. IF <br /> ❑ l RESTAURANT DOES NOT RECEIVE KIOSK, PROVIDE J-BOX AND 112" o9?,OFESS��H <br /> / - [3] I CONDUIT WITH PULL STRINGS TO TWO (2) SPARE 20A/1 P BREAKERS ����p.FE <br /> WITHIN CP PANEL. "ALL ELECTRICAL FEEDS FOR THE KIOSKS ARE TO <br /> HANDLED BY THE GENERAL CONTRACTOR'S ELECTRICIAN ON SITE. 7 <br /> l 8 <br /> 9 'k <br /> `r�' �ECTFiICP�' �P <br /> l VERIFY IF OPTIONAL TABLE TRACKER SYSTEM IS TO BE USED. IF <br /> [27] USED, PROVIDE 2#12, 1#12 GRD, & Y,2 ISOLATED GRD. TO AVAILABLE <br /> 3 SPARE 20A/1 P BREAKER WITHIN CP PANEL. CONNECT CIRCUIT TO 4/24/19 <br /> TWO (2) IG RECEPTACLES, ONE (1 ) RECEPTACLE FOR SERVER <br /> ❑ ii (TYPICALLY LOCATED IN I.T. CLOSET AND ONE (1 )RECEPTACLE FOR <br /> 11 I MONITOR (TYPICALLY LOCATED AT HLS OR PICKUP COUNTER). <br /> COORDINATE EXACT LOCATION(S) IN THE FIELD AND REQUIREMENTS W 0 <br /> o WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. mo <br /> o ❑ Ili 0 <br /> ❑3 EXISTING POWER IN THIS AREA TO REMAIN. a <br /> I <br /> i I I i FOR RECEPTACLE CIRCUITRY REFER TO THE BOX NOTE ON THIS <br /> [4] SHEET. COORDINATE FINAL LAYOUT WITH DECOR AND OWNER y CD <br /> 3 i Cf :* ll 13 OPERATOR1 <br /> . TYPICAL. <br /> ❑ I I o <br /> 6 2 L � — — �. <br /> _ EC SHALL PROVIDE A DUPLEX RECEPTACLE AND A LOW VOLTAGE W 6 <br /> BROADBAND CONNECTION FOR THE INSTALLATION OF FLAT PANEL r a^� <br /> FIELD VERIFY 3'-0" NEC REQUIRED CLEARANCE IN Em 2 a v E <br /> FIELD VERIFY TELEVISIONS. COORDINATE EXACT LOCATIONS WITH DECOR COMPANY. <br /> FRONT OF ELECTRICAL EQUIPMENT. COORDINATE o �Q o'� <br /> LOCATIONS OF EXISTING l FOR BROADBAND CONNECTION, EC SHALL PROVIDE A 4 X 4 BOX w O }V o <br /> J POWER PANELS WITH ACM/OWNER FOR RELOCATION OF SHELF m J o°) <br /> OVER PANELS WITH A 3/4" CONDUIT STUB UP WITH A BUSHING INTO ACCESSIBLE � o a <br /> DUAL POINT FRONT CEILING SPACE. RE-USE EXISTING CIRCUITRY. � ��� o <br /> ❑ COUNTER LAYOUT CONFIRM l �o�U <br /> RELOCATE/REUSE EXISTING ELECTRICAL CIRCUITRY LAYOUT WITH MCD <br /> ❑ FOR THE KITCHEN EQUIPMENT ASSOCIATED WITH CONSTRUCTION SUPERVISOR ROUGH IN FOR FUTURE DIGITAL BULLETIN BOARD. CONFIRM LOCATION l ❑6 c <br /> 3 THE SERVICE AREA MODERNIZATION. NO ADDITIONAL REFER TO DETAIL ON WITH ACM. o 0 :5 o a <br /> ❑ LOADS WILL BE ADDED. SHEET E4.0 0 a c .N <br /> l PROVIDE AN ALLOWANCE IN BID TO PROVIDE TWO(2) FLEXIBLE POWER Q � o o 7 o 0 0 <br /> -D _ <br /> 7 CONNECTIONS FOR POWER TO FURNITURE/ FAMILY EXPERIENCE v J o <br /> ELEMENTS AS PART OF THE DECOR PACKAGE. VERIFY EXACT Q L ° 0 ° <br /> LOCATIONS IN FIELD AND WITH DECOR DRAWINGS. PROVIDE ALL ° <br /> � � � � <br /> NECESSARY MATERIALS AND LABOR FOR A COMPLETE AND FULLY NEC o g o m <br /> CODE COMPLIANT INSTALLATION. ALL COMPONENTS SHALL BE FED a o L <br /> FROM A GFCI TYPE CIRCUIT BREAKER AND BRANCH CIRCUIT SHALL E E <br /> N <br /> CONTAIN TWO PATHS OF GROUNDING (CONDUIT BODY AND AN -3 <br /> L <br /> t a Q <br /> INSULATED GROUNDING CONDUCTOR) TO COMPLY WITH McDONALD'S O o -oa .3 a Q)GROUNDING STANDARDS. a � o o °a o <br /> t = a t m a c <br /> cn - U N Q a <br /> REUSE EXISTING FRONT COUNTER CIRCUITS WHERE POSSIBLE. REFER T o �.N E - , <br /> TO DETAIL ON SHEET E4.0. PROVIDE (4) 20A, 120V I.G. CIRCUITS a °Ca X2 o <br /> a <br /> FROM PANEL CP AND (1) 20A, 120V CIRCUIT FROM A SPARE C/B ISI v <br /> AN AP PANEL TO FEED FRONT COUNTER POS EQUIPMENT, TABLE <br /> MATCH LINE TRACKERS AND UBER TABLET. (1 ) 20A, 120V CIRCUIT FROM A SPARE o o <br /> C/B IN AN AP PANEL TO FEED 2 DCO'S SERVING THE BAKED GOODS a <br /> 1 ELECTRICAL POWER PLAN DISPLAY. IF THERE IS NOT SUFFICIENT CAPACITY IN THE EXISTING 0 W- . - 0 <br /> E1 . 1 COMPUTER PANEL FOR THE NEW COMPUTER CIRCUITS, THEN Q a � � o ° T <br /> 1 4" = 1 ' 0" CONTRACTOR IS TO REPLACE THE EXISTING PANEL WITH A NEW 42 a o Q-1,2 <br /> Q o <br /> CIRCUIT PANEL OF THE SAME AMPACITY AS THE EXISTING. NEW PANEL � U o 0-- <br /> SHALL <br /> SHALL BE OF THE SAME MAKE, MODEL, MANUFACTURER AND HAVE .- <br /> THE SAME AIC RATING AS THE EXISTING PANEL. o 3 0 ° o <br /> ELECTRICAL RACEWAY PROVIDED WITH COUNTER AND INSTALLED BY 0 � o > <br /> E.C. REFER TO DETAIL ON SHEET E4.0 w - o o <br /> m H a3� <br /> E.C. SHALL PROVIDE (5) CONVENIENCE OUTLETS WITHIN THE <br /> DINING AREA FOR CUSTOMER USE, AND (1) OUTLET AND DATA ❑ EXISTING POWER IN BATHROOMS TO BE RELOCATED AS NEEDED PER z oca <br /> w <br /> FOR TELEVISION. E.C. AND G.C. SHALL VERIFY EXACT 10 NEW ADA COMPLIANT BATHROOM LAYOUT. EXTEND EXISTING CONDUIT m o °� m o w o � <br /> QUANTITIES AND LOCATIONS IN THE FIELD WITH McDONALD'S AND CIRCUITRY TO NEW DEVICE LOCATIONS. NO ADDITIONAL LOADS z -D 0 <br /> AREA CONSTRUCTION MANAGER AND FINAL DECOR DRAWINGS. WILL BE ADDED TO EXISTING CIRCUITS. Q Q w � w N a N <br /> SYMBOLS AND ABBREVIATIONS ALL DINNING AREA RECEPTACLES SHALL BE TAMPERPROOF o o Q o c� o <br /> TYPE PASS & SEYMOUR "SAFELOCK" 2095-TR OR PROTECTED v o <br /> BY AN UPSTREAM GFCI TYPE CIRCUIT BREAKER OR DEVICE. 11 1 .5" CONDIUIT AND BOX AT 7' 10" FOR RELOCATED ORB. REUSE <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION E.C. SHALL PROVIDE AT LEAST (2) BRANCH CIRCUITS TO FEED EXISTING POWER AND DATA U <br /> THESE CUSTOMER RECEPTACLES AND SHALL PROVIDE ALL <br /> (19- SINGLE POLE SWITCH, 3W-THREE WAY SWITCH, K=KEYED SWITCHED, 9-T MANUAL SWITCH (TTHERMAL OVERLOADS) MATERIAL AND LABOR FOR A COMPLETE AND FULLY DRAFT STOP ABOVE CEILING. E.C. TO ENSURE INTEGRITY OF FIRE <br /> VS=VACANCY SWITCH O BUZZER FUNCTIONAL OUTLET SYSTEM. THESE OUTLETS SHALL NOT BE 12 RATED WALLS WHERE ELECTRICAL EQUIPMENT PENETRATES WALLS. z <br /> ISOLATED GROUNDING TYPE. TOTAL ADDED LOAD 9 AMPS. SEAL PER SPECIFICATIONS FOR FIRE STOPPING. <br /> ® JB WITH DUPLEX CONVENIENCE OUTLET (FLUSH WITH CEILING) © BUTTON FOR BUZZER REUSE EXISTING DINING AREA RECEPTACLE CIRCUITRY WHERE <br /> �{ JB WITH SINGLE CONVENIENCE OUTLET G PANELBOARD POSSIBLE. EXTEND 2 1/2" CONDUIT FROM 1 '-2" AFF TO ABOVE CEILING FOR <br /> 13 POS DATA CABLES. IF THERE IS NOT ENOUGH SPACE IN WALL TO <br /> JB WITH DUPLEX CONVENIENCE OUTLET A AMPERES ROUTE CONDUIT TO ABOVE CEILING, CONTRACTOR TO TRENCH TO <br /> JB WITH TWO DUPLEX CONVENIENCE OUTLETS ACM AREA CONSTRUCTION MANAGER NEAREST FULL HEIGHT WALL AND EXTEND 2 1/2" CONDUIT TO ABOVE 1, <br /> CEILING. <br /> O JB WITH FLUSH FLOOR MOUNTED OUTLET AFF ABOVE FINISHED FLOOR z Q <br /> JB WITH SPECIAL PURPOSE OUTLET C CONDUIT ELECTRICAL LOAD CALCULATION 0 o z <br /> CP:* IF THERE IS NOT SUFFICIENT CAPACITY IN THE EXISTING � w <br /> ® JB WITH ISOLATED GROUND OUTLET 0 CCT CIRCUIT EXISTING INTERIOR LIGHTING REMOVED - -5.7 I(W Z w � <br /> O O COMPUTER PANEL FOR THE NEW COMPUTER CIRCUITS THEN <br /> =IG4700A, =IG5262 D Q V) a <br /> CONTRACTOR IS TO REPLACE THE EXISTING PANEL WITH A NEW 42 <br /> IG471 0, IG5261 , NEW COMPUTER CIRCUITS 2.5 I<W <br /> EC ELECTRICAL CONTRACTOR w <br /> CIRCUIT PANEL OF THE SAME AMPACITY AS EXISTING. NEW PANEL NEW INTERIOR LIGHTING 1.3 I<W o w o w <br /> N INTERCOM STATION W/ 3/4"C TO MAIN STATION GC GENERAL CONTRACTOR SHALL BE OF THE SAME MAKE, MODEL, MANUFACTURER AND HAVE LL m a <br /> 1< TELEPHONE JACK GFI GFCI GROUND FAULT CIRCUIT INTERRUPTER THE SAME AIC RATING AS THE PANEL BEING REPLACED. O z 0 w <br /> / NEW ESTIMATED LOAD KW -1.9 KW - <br /> O JUNCTION BOX - WALL OR CEILING MOUNTED GND GROUND NEW ESTIMATED LOAD AMPS - -5.4 AMPSJ u <br /> W Z Q <br /> ❑� <br /> 0 z <br /> DISCONNECT SWITCH IG ISOLATED GROUND 00 a o <br /> N <br /> 0 0 <br /> O THERMOSTAT SENSOR W/ 1/2"C- UP TO CEILING SPACE JB JUNCTION BOX ON W o o0 w o <br /> MOTOR CONNECTION KES KITCHEN EQUIPMENT SUPPLIER cn <br /> CONDUIT RUN CONCEALED IN CEILING OR WALLS MLO MAIN LUGS ONLY <br /> 0 <br /> z <br /> / \ CONDUIT RUN IN FLOOR SLAB WP WEATHERPROOFE 1 <br /> HOT SHORT NEUTRAL LONG , EQUIP GRD LONG WITH DOT , & w • <br /> X & 'X' DENOTES ISOLATED GRD <br /> OS GEEING MOUNTED OCCUPANCY SENSOR U) POWER PLAN <br />