KEY NOTES <br /> I m <br /> EC SHALL INSTALL AND CONFIGURE REMOTE EMERGENCY <br /> LIGHTING AT ALL EGRESS EXTERIOR DOORS FOR MAXIMUM <br /> ILLUMINATION AT POINTS OF EGRESS. INSTALL WP J–BOX <br /> WITHIN SOFFIT TO ALLOW A FLUSH INSTALLATION OF ANY <br /> EXTERIOR EMERGENCY EGRESS LIGHTING (TYPICAL). USE <br /> EXISTING EMERGENCY CIRCUITRY FOR NEW EMERGENCY LIGHT. <br /> CONVERSION TO LED LIGHTING THROUGHOUT 2 ALL SOFFIT LOCATIONS, LIGHTING, & SUPPLY GRILLS SHALL BE <br /> THE CUSTOMER AREAS. MAINTAIN EXISTING COORDINATED WITH DECOR COMPANY DRAWING PRIOR TO <br /> CIRCUITRY AND CONTROL UNLESS NOTED INSTALLATION. <br /> MATCH LINE OTHERWISE. CONFIRM LOCATION AND NOT USED. <br /> LAYOUT WITH DECOR COMPANY AND 0 z <br /> SECURITY LIGHTING DRAWINGS PRIOR TO PROVIDE POWER FOR LIGHT WITHIN TOY DISPLAY. COORDINATE EXACT <br /> INSTALLATION. NEW LIGHTING PACKAGE IS [4] LOCATION WITH DECOR DRAWINGS. CONTROL WITH DINING LIGHTING. <br /> MORE EFFICIENT WITH AN OVERALL <br /> REDUCTION ON LIGHTING LOADS U <br /> 5 EXISTING LIGHTING TO REMAIN.. � <br /> w <br /> ❑ <br /> 0 <br /> OPROVIDE DUAL–LITE LIGHTING INVERTER MODEL #LG1 –T FOR <br /> USE WITH TYPE F12S, F12SA & F12T FIXTURES SHOWN WITH <br /> "FM" TAG. E.C. SHALL FIELD VERIFY EXACT QUANTITY AND <br /> e 12 e e 0> LOCATION OF DEVICE PRIOR TO INSTALLATION. WHEN OPTIONAL <br /> YP. F12SA F15&F15A FIXTURES ARE USED, E.C. SHALL VERIFY QUANTITY <br /> F14A F1 4A F14A OF FIXTURES THAT CAN BE CONNECTED TO INVERTER WITHOUT <br /> FOe e 14 e EXCEEDING OPERATING CAPACITY OF UNIT AND PROVIDE <br /> S FOS TYP. FOS ADDITIONAL CIRCUITS AND INVERTERS AS REQUIRED. (TYPICAL) <br /> S 0e ❑ EXISTING ENERGY MANAGEMENT SYSTEM (EMS) WITH ASTRONOMICAL TIME <br /> F12SA CLOCK, LIGHTING CONTACTORS AND MANUAL OVERRIDE FOR DINING AND <br /> RESTROOM CIRCUITS. FIELD VERIFY LOCATION. <br /> 6 2 REUSE EXISTING OCCUPANCY SENSOR FOR LIGHTING CONTROL. IF NONE, < <br /> DAYLIGHT ZONE O PROVIDE DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR OR o <br /> TYP. f e WALL MOUNTED VACANCY SENSOR AS SHOWN. ORDER ALL SENSORS FROM <br /> a I 0 0 e SECURITY LIGHTING SYSTEMS, INC. <br /> F12S F12S > <br /> 0 <br /> F12S I F1 4 � <br /> I ❑ REUSE EXISTING CIRCUITRY FOR NEW BATHROOM LIGHTS. <br /> 9 EXTEND EXISTING CONDUIT AND CIRCUITRY TO NEW LOCATIONS <br /> 14 I AND MAINTAIN EXISTING LIGHTING CONTROLS. NO ADDITIONAL OFESS/ <br /> TYP. DS LOADS WILL BE ADDED TO EXISTING CIRCUITS. �e��e '.FE � <br /> fe 10 RE–USE EXISTING EMERGENCY LIGHTING CIRCUITRY FOR <br /> Da 0 0 BATHROOM EMERGENCY LIGHTING. EMERGENCY/NIGHT LIGHT <br /> F12S I F12S F12S e FIXTURES TO BE NON SWITCHED, TYPICAL. <br /> Fl 4A <br /> 11 RE–USE EXISTING EMERGENCY LIGHTING CIRCUITRY FEEDING r4TFoE �`Fo���P <br /> ITHIS AREA FOR EXIT SIGN. <br /> 04/24/19 <br /> I12 PENDANTS ARE TO BE CENTERED OVER TABLES. TYPICAL. <br /> Oa <br /> 13 DRAFT STOP ABOVE CEILING. E.C. TO ENSURE INTEGRITY OF i� = <br /> 0 f e FIRE RATED WALLS WHERE ELECTRICAL EQUIPMENT PENETRATES W 0 <br /> F12S I FOS F12S WALLS. SEAL PER SPECIFICATIONS FOR FIRE STOPPING. w <br /> F22 1 <br /> I14 NEW DAYLIGHT SENSOR TO BE INSTALLED TO CONTROL DAYLIGHT AREAS I\M <br /> I THE DINNING AREAS. ORDER ALL DAYLIGHT SENSORS FROM; SECURITY <br /> F20 LIGHTING SYSTEMS, INC. N <br /> I <br /> 0a I 0 F22 15 DIMMER SWITCHES FOR CUSTOMER AREAS CONFIRM LOCATION �. <br /> F12S F12S e WITH AREA CONSTRUCTION MANAGER AND ARCHITECTURAL. W <br /> I 0 11 YSWITCH a–MAIN LOBBY NON–DAYLIGHT r Q-�� <br /> F12S TYP. <br /> m 2a� o <br /> SWITCH b–FRONT COUNTER o V o q <br /> P 0) <br /> I F1 4D SWITCH c–MENS RESTROOM w° <br /> p a C N <br /> e SWITCH d WOMFNS RESTROOM �o v <br /> w <br /> Ca O I SWITCH e–MAIN LOBBY PRIMARY DAYLIGHT ZONE <br /> F12S F0 SWITCH f–MAIN LOBBY SECONDARY DAYLIGHT ZONE o <br /> ° ° <br /> V N <br /> _______________________________________ F14D E.0 IS TO ROUTE ALL NON EMERGENCY CIRCUITRY THRU EXISTING ° ° ° o ° o.L <br /> e 16 0 � o-°o-a <br /> 0a 0a LIGHTING CONTROL SYSTEM FOR AUTOMATIC SHUTOFF. TYPICAL. U J o Q° o <br /> F12S F12S J <br /> 17 PROVIDE PILOT SWITCHES FOR ALL CONTROLS WITH AN ALTERNATE SWITCH E.o <br /> FOR AREAS OUT OF SIGHT OF MAIN CONTROL. o ° co U)" Q <br /> U U <br /> U o — <br /> � C N i L U <br /> N rn N N N <br /> O� N o <br /> O a U 7F a Q <br /> N <br /> o o � 3 a t <br /> _ L o a— <br /> O O O <br /> U <br /> U <br /> fn U O U o <br /> Q O <br /> C C n <br /> -p o , (n U C <br /> U C U '� O H O <br /> ° o+� X _ <br /> N' o <br /> EMERGENCY LIGHTING NOTES — 0 U ° <br /> 0~ c 0 <br /> ELI. EC SHALL INSTALL A LOCK ON CIRCUIT BREAKER HANDLE, FOR ALL Q R <br /> EMERGENCY LIGHTING CIRCUITS. EC SHALL VERIFY ALL REQUIREMENTS Un .o <br /> MATCH LINE AND FINAL EMERGENCY LIGHTING LOCATIONS WITH LOCAL AUTHORITIES. O w v ° <br /> INCLUDE ALL COSTS IN BASE BID. Q �� .o ° ° Q) <br /> 1 PARTIAL ELECTRICAL �LIG�HTIN�GP�LIN�, EL2. IF NOT INSTALLED BY MANUFACTURER, EC SHALL BE RESPONSIBLE FOR ♦ + ° o ° o 0 <br /> THE COMPLETE INSTALLATION OF THE EMERGENCY INVERTER IN NIGHT V V Q o cn L a <br /> E2. 1 1 /4 — 1 —0 LIGHTING FIXTURES SHOWN ON THIS SHEET. ° <br /> Lo 3:'o � � <br /> EL3. LED FIXTURES DENOTED AS NIGHT LIGHTING OR SWITCHED EMERGENCY o ® a >,3 Q) -L°o o C <br /> SHALL BE APPROVED WITH DUAL LITE LIGHTING INVERTER MODEL # � ° v o -3 U) °.0 ° <br /> LG125T. INVERTER SHALL BE CAPABLE OF ILLUMINATING FIXTURE FOR 1 .5 0- Q) 0 – – w L ° <br /> HOURS TO COMPLY WITH NEC SECTION 700 AND UL924. E.C. SHALL a 3 0 0 <br /> NOT INSTALL MORE THEN EIGHT FIXTURES TO EACH INVERTER. PROVIDE w <br /> ADDITIONAL NVERTERS AS NECESSARY. w <br /> � z o � � co <br /> SEE DRAWING E1 .0 FOR EL4. EMERGENCY BATTERY LIGHTING WALL PACKS IN PLAYPLACE SHALL BE m w o o u 0 <br /> LOCATED SO AS TO PROVIDE FOR MAXIMUM ILLUMINATION OF AREA. z � N w C/)CD 0 N <br /> LIGHTING FIXTURE SCHEDULE EC SHALL VERIFY EXACT PLACEMENT IN THE FIELD WITH McDONALD'S Q Q M w � w N a <br /> AND GENERAL NOTES. AGM. (IF APPLICABLE) o o Q � � o <br /> N O <br /> EL5. EMERGENCY LIGHTING HAS BEEN DESIGNED PER NEPA 101 TO MAINTAIN 1 <br /> FC IN PATH OF EGRESS. IF FIELD CONDITIONS REQUIRE ANY <br /> CHANGES TO LIGHTING DESIGN, EMERGENCY LIGHTING, SHALL BE <br /> INSTALLED TO MEET THE ABOVE REQUIREMENTS. d <br /> U <br /> W <br /> GENERAL NOTES FOR DRAWING E2 . 0 : GENERAL NOTES FOR DRAWING E2 . 0 : PROJECT DEMOLITION NOTES : D3. THE ELECTRICAL CONTRACTOR SHALL RELOCATEAL AO EXTERIOR ROOF <br /> MOUNTED GENERAL PURPOSE OUTLETS AND ALL PHOTOCELLS AS REQUIRED <br /> OUTDOORS LIGHTING INSTALLATION METHODS THE FOLLOWING PROVIDES A GENERAL SCOPE OF WORK FOR THE TO ALLOW FOR THE NEW FACADE INSTALLATION. COORDINATE EXACT <br /> ELECTRICAL CONTRACTOR FOR THE DEMOLITION REQUIREMENTS OF THIS EXTENT OF WORK WITH ARCHITECTURAL DRAWINGS AND IN THE FIELD WITH <br /> PI . E.C. SHALL PROVIDE AN ADDITIVE ALTERNATE COST (ELEC–DT-1) 1 . ALL LIGHT FIXTURES SHALL BE 120 VOLT UNLESS NOTED OTHERWISE. 7. EC SHALL INSTALL ALL SOFFIT LIGHTINGTHE PROJECT MANAGER. RECEPTACLES SHALL BE INSTALLED SO AS TO BE <br /> TO PROVIDE POWER FOR A NEW MENU BOARD, POWER AND DATA FIXTURES AWAY FROM BUILDING WALL. SITE. THIS SECTION IS NOT ALL INCLUSIVE, AND THE CONTRACTOR SHALL WITHIN 25' 0" OF ANY ROOFTOP HVAC EQUIPMENT PER NEC 210.63. <br /> FEEDS AND CONNECTIONS FOR A NEW COD, AND A LANE 2. LIGHTING FIXTURES AND LAMPS HAVE BEEN CHOSEN TO ACHIEVE MAXIMUM ENERGY CONSERVATION WHILE MAINTAINING ADEQUATE LEVEL FIXTURES SHALL BE LOCATED TO AVOID VISIT THE SITE AND COMPARE EXISTING CONDITIONS TO THE <br /> REQUIREMENTS DENOTED ON THE CONSTRUCTION DOCUMENTS TO W <br /> MONITOR. COD LOCATIONS SHALL EACH BE PROVIDED WITH A NEW OF ILLUMINATION. LAMP SPECIFICATIONS SHALL BE STRICTLY FOLLOWED. ANY DEVIATION FROM LAMP SPECIFICATIONS SHALL BE INTERFERENCE WITH STRUCTURAL D4. E.C. SHALL VERIFY WHETHER EXISTING OUTDOOR RECEPTACLES ARE GFCI <br /> ISOLATED GROUNDING TYPE CIRCUIT, AND A NEW 2" DATA APPROVED IN WRITING BY McDONALD'S CORPORATION. MEMBERS ABOVE SOFFIT. DETERMINE THE EXACT EXTENT OF THE DEMOLITION WORK REQUIRED. E.C. <br /> PROTECTED. IF NOT, E.C. SHALL PROVIDE NEW GFCI TYPE PROTECTED o <br /> SHALL PROVIDE ALL DEMOLITION WORK REQUIRED IN ORDER TO ALLOW z Q w <br /> CONDUIT TO NEW LOCATION. ALL WORK AND INSTALLATION RECEPTACLE DEVICES IN PLACE OF EXISTING. E.C. SHALL ALSO PROVIDE U 0 z <br /> FOR THE COMPLETE INSTALLATION AS DENOTED WITHIN THESE DRAWINGS. O F w <br /> 3. PROVIDE A WEATHERPROOF JUNCTION BOX IN PARAPET FOR FASCIA SIGNS. FINAL CONNECTION BY OTHERS. VERIFY EXACT LOCATION OF 8. THE USE OF "MC" CABLE IN LENGTHS OF WEATHERPROOF COVERS FOR ALL OUTDOOR RECEPTACLES TO COMPLY Q o <br /> LOCATIONS SHALL BE COORDINATED WITH THE MCDONALD'S z � W <br /> PROJECT MANAGER PRIOR TO INSTALLATION. SIGN WITH Mc DONALD'S PROJECT MANAGER PRIOR TO INSTALLATION. 6 FEET OR LESS (WHERE PERMITTED BY WITH NEC SECTION 406.8(B). _ <br /> LOCAL CODES) SHALL BE ALLOWED FOR OUTDOOR BUILDING LIGHTING POWER Q w g <br /> P2. E.C. SHALL PROVIDE POWER FOR NEW EXTERIOR LAWN MOUNTED 4. EC SHALL COORDINATE LOCATION OF ALL EXTERIOR LIGHTS WITH Mc DONALD'S PROJECT MANAGER TO AVOID INTERFERENCE WITH ANY WIRING TO THE LIGHTING FIXTURES. GENERAL — o W o <br /> WALL WASHING LIGHT FIXTURES AS LOCATED ON SITE PLAN. CORBELS, TRUSSES, BEAMS OR OTHER SPECIAL EXTERIOR TREATMENTS. INSTALL LIGHT FIXTURES WITH CORRECT ORIENTATION PER "ROMEX" OR "BX" SHALL NOT BE USED. U1 . THE ELECTRICAL CONTRACTOR SHALL DISCONNECT AND REMOVE ALL OF F, = o <br /> MANUFACTURER'S INSTRUCTIONS. _> THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE SALVAGE LL m w a <br /> THE EXTERIOR ILLUMINATED ROOF BEAMS FROM THE BUILDING. REMOVE W W <br /> 9. EC SHALL VERIFY THAT NOT MORE THAN REQUIREMENTS FOR ALL EQUIPMENT REMOVED AS PART OF THE z 0 <br /> ALL FIXTURES, WIRING, WHIPS, AND CONDUIT TO ALLOW FOR THE NEW O � <br /> 5. EC SHALL FIELD VERIFY THAT ALL LIGHT FIXTURES SHOWN ON THIS PLAN 3% VOLTAGE DROP EXISTS FROM THE DEMOLITION WORK WITH THE CONSTRUCTION PROJECT MANAGER. ALL W O Q w <br /> DO NOT OBSTRUCT OR CONFLICT WITH THE WORK OF OTHER TRADES. LIGHTING PANEL TO ANY EXTERIOR FACADE INSTALLATION AS DENOTED ON THE PLANS. COORDINATE ALL WORK <br /> WITH OTHER TRADES AND WITH THE PROJECT MANAGER. EQUIPMENT TO BE SALVAGED AND/OR REUSED SHALL BE PROTECTED Z 0 0 z <br /> IF A DISCREPANCY IS FOUND, THE EC SHALL IMMEDIATELY NOTIFY THE LIGHTING FIXTURE OR SIGNAGE BALLAST. FROM DAMAGE UNTIL REINSTALLED OR THE TIME PERIOD WHEN IT IS O a Ld L n <br /> GC BEFORE THE INSTALLATION OF SUCH FIXTURE(S). — <br /> D2. THE ELECTRICAL CONTRACTOR SHALL DISCONNECT AND REMOVE ALL TURNED OVER TO THE OWNER AND/OR THE PROJECT MANAGER. Ir <br /> 0 :5 n- � �i <br /> EXTERIOR ELECTRICALLY POWERED FASCIA SIGNAGE FROM THE BUILDING. I x w o0 w o <br /> 6. ORDER LED EXIT SIGNS WITH LETTER COLORS THAT COMPLY WITH LOCAL CODES FROM SECURITY LIGHTING. D6. SEE THE GENERAL ELECTRICAL SPECIFICATIONS AND NOTES ON SHEET N W cn 0 <br /> – FOR RED LETTERS USE #PRB (UNIVERSAL), SPECIALITY LIGHTING REMOVE ALL SIGNAGE, WIRING, WHIPS, AND CONDUIT TO ALLOW FOR THE E1 .0 FOR ADDITIONAL GENERAL REQUIREMENTS. <br /> NEW FACADE INSTALLATION AS DENOTED ON THE PLANS. COORDINATE ALL <br /> – FOR GREEN LETTERS USE #PGB (UNIVERSAL), OR 10. SEE THE ARCHITECTURAL DRAWINGS FOR WORK WITH OTHER TRADES AND WITH THE PROJECT MANAGER. D7. THE ELECTRICAL CONTRACTOR SHALL DISCONNECT AND REMOVE ALL o <br /> IF THE ABOVE EXIT SIGNS DO NOT COMPLY WITH LOCAL CODES USE: LED SIGN WITH BATTERY BACKUP, LETTER SIZE, COLOR, TYPE & EXACT LOCATIONS AND REQUIREMENTS FOR z <br /> DIRECTIONAL ARROWS AS REQUIRED BY THE LOCAL AUTHORITIES. THE FACADE ARCADE LIGHTING ELEMENTS, EXISTING LIGHT FIXTURES IN THE AREAS ASSOCIATED WITH THE <br /> AND CANOPY ELEMENTS. REMODEL TO ALLOW FOR THE NEW LIGHTING FIXTURE INSTALLATION AS w E29 1 <br /> 7. ALL NON EMERGENCY LIGHTING IS TO BE ROUTED THROUGH THE BUILDING ENERGY MANAGEMENT SYSTEM FOR COMPLETE BUILDING DENOTED ON THE PLANS AND DECOR DRAWINGS. COORDINATE ALL PARTIAL LIGHTING PLAN <br /> LIGHTING AUTO SHUT–OFF WORK WITH OTHER TRADES AND WITH THE PROJECT MANAGER. <br />