Laserfiche WebLink
� <br /> Panel: L Voltage: 120/208v, 3113h, 4w DUNHAM <br /> Code L Code C Code R Code M Code E Code K Code D Dunham Associates of Minnesota, Inc. <br /> No. Amp/p Note Description Ph VA VA VA VA VA VA VA <br /> 50 South Sixth Street/Suite 1100 <br /> 1 20/1 2 SALES LIGHTS -A- 360 <br /> Minneapolis, Minnesota 55402-1540 <br /> 3 20/1 2 SELF SERVICE DISPLAY CASE LIGHTS - B - 240 <br /> 5 20/1 2 SALES LIGHTS -C- 418 <br /> PHONE 612.465.7550 FAx 612.465.7551 <br /> 7 20/1 SPARE -A- wEe dunhameng.com <br /> 9 20/1 2 STOCK ROOM, BATHROOM LIGHTS, EF - B - 340 100 mechanical +electrical consulting engineering <br /> 11 20/1 3 TIMECLOCK -C-1 50 PROJECT NO. 0421743-001 <br /> 13 20/1 SPARE -A- <br /> 15 20/1 SPARE - B - <br /> 17 20/1 SPARE -C- �OVE:S <br /> 19 20/1 2 STOREFRONT SIGN -A- 1200 <br /> 21 20/1 SPARE - B - O RO0 <br /> 23 20/1 SPARE -C- t, r <br /> 25 --- SPACE -A-1 I <br /> 27 <br /> A- <br /> 27 20/1 CASH REGISTER1 - B - 720 <br /> 29 20/1 CASH REGISTER2 -C- 360 ' <br /> 31 --- SPACE -A- .t�9<FcTR�GPc <br /> 33 --- S PACE - B - D. , hl <br /> 35 --- SPACE -C- DN:CN=Jay D Rohkohi, =AO1427 000 83E80225C00009AD1, <br /> O=DUNHAM ASSOCIATES,C=US <br /> 37 40 1 WH-1 -A- 3333 Date:2020.08.11 08:15:18-05'00' <br /> 39 / - B - 3333 <br /> 41 3 -C- 3333 <br /> 2 40 RTU-1 -A- 3240 <br /> 4 / " - B - 3240 <br /> 6 3 " -C- 3240 <br /> 8 20/1 RTU RECEPTACLE -A- 180 <br /> Fault current calculations and AIC design are based on the following assumptions. 10 20/1 COUNTER RECEPTACLES - B - 720 <br /> 12 20/1 LED STRIPS, COUNTER RECEPT -C- 180 50 <br /> 61,960 Short Circuit Amps Available at Service Entrance 14 20/1 STOCKROOM RECEPTACLES -A- 900 <br /> 4sets,2"C Metal,4#3/0 CU Conduit and Wire 1 75' 1 Distance From I XFMR I To I 200A D.S. 16 20/1 3 DUCT SMOKE DET. - B - 50 <br /> 1 set,2"C Metal,4#3/0 CU Conduit and Wire 1 50' IDistanceFroml 200A D.S. ITol PANEL L 18 20/1 SPARE -C- MBA Architects, Inc. <br /> 20 20/1 SHOW WINDOW RECEPTACLES -A- 360 N5560 CTH ZM, SUITE 3 <br /> 22 20/1 MANAGER'S DESK RECEPTACLES - B - 720 <br /> All conductors based on copper unless noted otherwise 24 20/1 MICROWAVE -C- 1800 Onalaska, WI. 54650 <br /> NOTES TO ELECTRICAL CONTRACTOR 26 20/1 REFRIGERATOR -A-I 500 1 LL: 587-45 -8034 <br /> A.Electrical Contractor upon being awarded contract,shall contact the utility to obtain the actual 28 20/1 CONTROLLED RECEPT. - B - 180 E-mail: mbOpm.timOgmail.COm <br /> available fault current and verify all above information upon arrival on site,prior to ordering or 30 20/1 MGR's DESK RECEPTS 2 -C- 360 <br /> approving release of equipment and report updated information to contact below.Engineerwill 32 20/1 SPARE -A- <br /> recalculate available fault currents and relay results to the Electrical Contractor for compliance with 34 20/1 SPARE - B - <br /> 36 20/1 SPARE -C- <br /> NEC 110.24(A),(B)field marking requirements.This proceedure shall be done for all new and/or 38 --- SPACE -A- <br /> relocated switchgear and/or panels regardless of current code adoption. 40 --- SPACE - B - <br /> B.Electrical Contractorto provide arc-flash hazard warning field marking per NEC 110.16. 42 --- SPACE -C- <br /> Through NONE -A- <br /> C.Electrical Contractorto provide series rated labeling per NEC 110-22(B)where there is an applied Feed Lug ---- - B - CLIENT'S <br /> STORE NUMBER SF-94 <br /> series rating as shown on the drawings. Connection ---- -C- <br /> Main --- -A- 1560 1440 3833 3240 0 0 0 <br /> D.Any additional costs for failure to comply with the above requirements will be strictly at Breaker EXIST. 200A/3P - B - 580 1 1620 4103 3340 0 0 0 <br /> contractors expense. --- -C- 418 1 540 5593 3240 0 0 0 SEE. S CANDIES <br /> Overcurrent Device Notes: Total -A- -B - -C- <br /> Engineering Contact: Mark Carlson 1 - PROVIDE LOCK-OFF DEVICE Conn KVA phase loads 29.5 10.1 9.6 9.8 <br /> Dunham Associates, Inc. 2- CONTROL VIA CONTACTOR/ TIMECLOCK Dmd Conn Bus KVA loads <br /> mark.carlson@dunhameng.com 3- PROVIDE LOCK-ON DEVICE 3.2 2.6 Code L- Lighting <br /> 612-465-7675 1 <br /> 4- 3.6 3.6 Code C- Convenience Receptacles (180 W) <br /> 5- 13.5 13.5 Code R Receptacles (Non Convenience) <br /> Panelboard Notes: 11.3 9.8 Code M Motors Largest Mtr VA= 5760 <br /> 1 - ROUTE CIRCUIT THROUGH CONTACTOR 0.0 0.0 Code E Electric Heat <br /> 2- 0.0 0.0 Code K Kitchen Equip Dmd = 100% MANTECA, CA 95336 <br /> 3- 0.0 0.0 ICode D- Dwelling Units (Hotel/Motel Rooms) <br /> 4- 32 30 ITotal KVA <br /> 5- 0 Spare KVA Spare=T- 0% <br /> RELOCATE : Mounting 32 Adjusted KVA(Demand + Spare KVA) <br /> LANDLORD'S SPACE TENANT'S SPACE EXISTING : Amps AIC Rating 88 Adjusted Amps(Demand + Spare KVA) <br /> 200 : Amp Rating of Bus 91 High Phase Amps(Demand + Spare KVA) 8/11/2020 <br /> 200 : Panel Amp Rating (Min Main or Bus Rating) File Name: Project Number : Project Name <br /> 208 : Phase to Phase Voltage PANEL L 421743 SEE's <br /> 3423 S LA. CIENE:GA BLVD. <br /> LOS ANGELES, CA 90016 <br /> EXTEND EXISTING FEEDER TO NEW PANEL LOCATION. <br /> PH: 31101/287-4.6116 <br /> VERIFY A MINIMUM OF 4#3/0 AND#6 GND. <br /> EXISTING 200A FEEDER TO REMAIN FAX: 310/842-4436 <br /> VERIFY A MIN. OF 4#3/0 CU,#6 GND. <br /> SEE'S CONTACT <br /> ELECTRICAL LOAD SUMMARY RICHARD ESCALAN'TE <br /> 310/ 287-4616 <br /> CONNECT. DEMAND DEMAND <br /> EXISTING 200-AMP BREAKER LOAD TYPE LOAD (KW) FACTOR LOAD (KW) Tim R. Benson <br /> AND METER TO REMAIN �. PANEL ARCHITECT'S PROJECT MANAGER <br /> . <br /> 200 N LIGHTING 2.8 1.25 3.6 608/ 785-2760 <br /> 200A <br /> MCB RECEPTACLES 6.5 1.00 6.5 -v 0 <br /> M RELOCATED EXISTING PANEL <br /> WATER HEATER 10.0 1.00 10.0 .2 Q a <br /> CALCULATED AVAILABLE FAULT CURRENT. SEE 75 2 K 00 <br /> 15,173A dote s�° a v > comments <br /> - <br /> STATEMENT THIS SHEET. VERIFY ELECTRICAL H.V.A.C. 10.0 1.00* 12.2 ' 07/03/20 0 <br /> PANEL IS SUFFICIENTLY PROTECTED. BUILT <br /> TOTAL 29.3 32.3 <br /> PREM <br /> BIDE 08/1 1/20 0 0 0 0 <br /> LANDLORD'S ELEC. DISTRIBUTION SEE'S CANDIES PCOMIT <br /> SERVICE SIZING LOAD = 32.3 KW <br /> 32.3 KW @ 480V/3PH = 39 AMPS <br /> NOTE: ELECTRICAL CONTRACTOR MUST VISIT SITE PRIOR TO BID AND FIELD VERIFY EXISTING CONDITIONS. <br /> NOTIFY ENGINEER OF ANY DISCREPANCIES. COORDINATE WITH LANDLORD. <br /> 1 ELECTRICAL RISER DIAGRAM VOLTAGE DROP CALCULATION <br /> drawn by: checked by: <br /> SERVICE: 1.732 x 200 AMPS x 0.092 x 50' DIV 1,000 DIV 208 = 0.77% <br /> E4NO SCALE BRANCH: 1.732 x 10 AMPS x 1.700 x 70' DIV 1,000 DIV 120 = 1.72% MC RM <br /> TOTAL = 2.49% <br /> THIS SHEET' CONTAINS: <br /> ELECTRICAL DETAILS <br /> CONTRACTOR SHALL VERIFY ALL PANEL SIZES, WIRE <br /> SIZES AND MAIN BREAKERS PRIOR TO BID. IF THERE <br /> ARE ANY DISCREPANCIES CONTRACTOR SHALL CONTACT <br /> OWNER OR ENGINEER PRIOR TO START OF <br /> CONSTRUCTION. <br /> E4 <br /> ARCHITECT'S COMMISSION NUMBER <br /> 20 - 1010 . 005 <br />