Laserfiche WebLink
(SSIPM) - SMART SENSOR/PRESSURE MODULE GENERAL i v O TL S <br /> (ISIM) - INTERSTITIAL SENSOR INTERFACE MODULE <br /> (PITIM) - PROBE/THERMISTOR INTERFACE MODULE <br /> IMPORTANT. THIS IS A CONTROL <br /> OUTER CABLE JACKET DRAWING ONLY AND DOES NOT <br /> TO SENSOR REFLECT THE ACTUAL LOCATIONS <br /> AC LINE OF CONDUIT ENTRY (SEE NOTE 7 <br /> AC NEUTRAL --ROBROYRIGID NO N-HAZARDOUS AREA PENSER SUMP #1 OTHERS SIM TO BELOW). <br /> u5 <br /> J.— PVC COATED CONTINUE TO DIS � � ❑ <br /> MONITOR (DCHASSIS GROUND CONDUIT OTHER DISPENSERS <br /> VEEDER-ROOT REQUIRES THAT ANYONE INSTALLING OUR <br /> BARRIER GROUND WEATHER/EXPLOSION � EQUIPMENT MUST BE LEVEL I CERTIFIED. FOR MORE <br /> TIE WRAP INFORMATION REGARDING THE HOME STUDY INSTALLERS <br /> PROOF JUNCTION BOXES SEALACOURSE CONTACT JOHN HOWELL 951-532-8599. <br /> BLACK <br /> • LIQUID SENSOR AT / PACK NT WARNING: IN INSTALLATION AND USE OF THIS7v <br /> DISPENSER SUMP PACKET / PRODUCT, COMPLY WITH THE NATIONAL <br /> ® • / ELECTRICAL CODE; FEDERAL, STATE AND LOCAL <br /> 0 O ® _ _ _.__ 794380-208 (ISIM) / / CODES. IN ADDITION,TURN OFF POWER AND TAKE <br /> ® ® I OTHER NECESSARY PRECAUTIONS DURING <br /> ® ISD PRESSURE } <br /> SENSOR ONLY AT -. �. WHITE.. � — � � INSTALLATION, SERVICE AND REPAIR TO PREVENT <br /> DIPENSER SUMP 1 � � � EPDXY SEALANT WIRE NUTS PERSONAL INJURY, PROPERTY LOSS AND <br /> • � ISD PRESSURE EQUIPMENT DAMAGE. PCOtO 0$-21-17 <br /> • • • • BLACK I WARNING: DISCONNECT ALL POWER BEFORE <br /> • - <br /> sENsoRY F+'T+2- --F��+��a 6�+� M <br /> SENSOR AT EPDXY SEALANT FOR, DIPENSER SUMP MAKING ANY CONNECTIONS TO PREVENT DEA <br /> (SSIPM) TWO-WIRE CONNECTIONS SERIOUS INJURY, EXPLOSION, OR ELECTRICAL <br /> m m @ @ m a @ m @ m m m @ 330020-315 ( SHOCK. MONITOR MUST NEVER BE OPERATED <br /> . • • • • SMART SEM R PRL SURE MODULE • + -WHITE — I UNLESS THE FRONT COVER IS CLOSED OVER THE <br /> BARRIER TERMINALS IN THE INTRINSICALLY SAFE flo <br /> M <br /> SENSOR q'�+V T T 4�+5-T+� +� �!IIIJ 51oa LO <br /> � � AREA. <br /> Ethernet/Phone line _'-.' � <br /> Communications 0 @ @ @ ¢ @ @ Z m @ @ @ - BLACK <br /> Compartment • • ISD FLOW METER <br /> . • • SMART BENS RrPRE SURE MODUL SENSOR AT 1. INTRINSICALLY SAFE WIRING X (� W <br /> SENSOR �' CO <br /> -:T --g3T4- --F6 -+��+a� ^, „u�5°s°R DIPENSER SUMP W <br /> (SS/PM) BONDED CONDUIT MEANS THAT THE METALLIC <br /> M11TERF11E: <br /> 330020-445 ( (D WSECTIONS OF CONDUIT ARE. PERMANENTLYm m m m m@ �# WHITE JOINED TO FORM AN ELECTRICALLY Z Z Q R LQ• INTERS €TIAL ENsaR MaDULE • CONDUCTIVE PATH THAT WILL ASSURE j © < L- ELECTRICAL CONTINUITY, AND THAT THE r [Y Q <br /> SENSOR I P I - +2-� 3_T+4 <br /> �4�v+ +6-__F- mum rsnnrcR <br /> ,g CONDUIT HAS THE CAPACITY TO CONDUCT Z U U <br /> ---- <br /> SAFELY, ANY CURRENT LIKELY TO BE IMPOSED. W d Z K Z Z <br /> @@m@m m 0 m CATEGORY <br /> INT ACE oDULE • .� 81-ACK � ~. OR CABLE PRICE CATEGORY 6 a)BONDED& NON-BONDED CONDUIT-THE � 0 w > 0 Q O <br /> • • • • • 1NrERS ITIAL ENSO IN RR BLA LIQUID SENSOR <br /> THERMISTOR <br /> • AT VENT SUMP SIGN CABLE WIRES BETWEEN THE MONITOR AND EACH W IY � ❑ � O Q <br /> PRoa / r-��`' PROBE - I I PROBE/SENSOR LOCATION MUST BE#14,#16 OR } W ti U F" <br /> THERAAI570 }��.+ -T�+3--1�-4��+1�-Ti-2�-I-3q+4urrunE (ISIM} <br /> PIN #18 AWG STRANDED COPPER WIRES W � J Q Z <br /> . T�P _ 794380-208 ATG PAD WITHIN A SHIELDED CABLE. SHIELDED CABLE I W III `� O <br /> it�jm <br /> . 3 MUST BE RATED AT LESS THAN 100 m 2 <br /> • • • • • PROBE/THERMISTOR INTERFACE MODULE WHITE PICOFARAD PER FOOT AND MUST BE <br /> — MANUFACTURED WITH A MATERIAL SUITABLE U ~ <br /> ® PAD FOR 88�OTHE ENVIRONMENT, SUCH AS BELDENTM o <br /> ® _ O cw) ® ® �• G �� ® ® WEATHER <br /> EXPLOSION PROOF TANK SUMP #3 2 Q <br /> JUNCTION BOXES — CAR N <br /> ROBROY RIGI --- �- �- 2 EARTH GROUND BUST AT THEPOWER <br /> THE: � <br /> PVC COATED TERMINATION POINTS FOR LIQUID SENSOR AT PIN <br /> CONDUIT SHIELDED CABLE FILL SUMP CATEGORY 6 PAD DISTRIBUTION PANEL WITH#12 AWG (OR <br /> I - LARGER)CONDUCTOR. <br /> BLACK <br /> • CABLE CATEGORY 6 <br /> TANK SUMP #4 (TANK #5 SIM BUT NOT SHOWN) (ISIM) CABLE 3.O DENOTES FIELD WIRING CONNECTION USING <br /> LAN CATEGORY 6 WATERPROOF CONNECTORS SUPPLIED WITH <br /> — —LIQUID SENSOR AT — — — 794380-245 � N- CABLE THE PROBES}AND SENSORS}. <br /> FILL SUMP -- + -(•SITE JUNIPER CISCO 0 0 0 000 4. INTRINSICALLY SAFE WIRING SHALL BE <br /> TCP/IP TO -----I I--��--� eL.a,cK - � ROUTER ROUTER EDH CATEGORY 6 INSTALLED IN ACCORDANCE WITH ARTICLE <br /> PROGURVE � LIQUID SENSOR AT VPN CABLE 504-20 OF THE NEC,ANSlINFPA 70. <br /> SWITCH {ISIM) TURBINE SUMP DATA 5. TO MAINTAIN INTRINSIC SAFETY, <br /> BLACK PORT 6 PROBE/SENSOR WIRING MUST BE INSTALLED <br /> 794380-208 - (ISIM) PAIRED GASOLINE <br /> BIR CABLE TO EDH -- -� TO FRAME RELAY WITH EITHER SEALED CONDUIT IR DIRECT <br /> WHITE + <br /> TELEPHONE LINE PUMP LOOPS CABLE IN TRENCH BURIAL METHODS, REFER TO"DIRE <br /> CT <br /> TO GASOLINE BURIAL CABLE INSTALLATION", MANUAL <br /> GAS CONTROLLER LIQUID SENSOR AT <br /> _ 794380-208 1-4 AS REQUIRED <br /> TURBINE SUMP I -� • WHITE DISPENSERS 576013-858. <br /> 6. ELECTRICAL RATING POWER INPUT 120 VAC, <br /> REFER TO THE 7-ELEVEN VEEDER ROOT INSTALLATION BLACK • - I <br /> PROTOCOL.GUIDE FOR SET UP AND CONFIGURATION OF (ISIM) TANK ANNULAR <br /> SENSOR AT <br /> TANK ANNULAR UPS D_BOX 50160 HZ, 100 VA MAXIMUM. � <br /> PAP <br /> REMOTELY MONITORED VEEDER ROOT EQUIPMENT. ` - _ - <br /> BLACK 7. THIS DOCUMENT 15 NOT TO BE USED AS A <br /> ENT 0 <br /> 794380-208 (ISIM) INSTALLATION STITUTE FOR IM <br /> MANUALS FOR INSTALLATIONad <br /> EWRITTEN SENSOR WHITE + <br /> CONTRACTOR SHALL PLACE A TYP DETAILS USE THE RESPECTIVE MANUAL: <br /> SCHEDULE THAT INDICATES WHICH CHANNEL IS HYDOSTATIC SENSOR AT 794380-303 Q o TLS-350(R) 576013-879 <br /> ASSOCIATED WITH WHICH SENSOR TANK ANNULAR --- -}- • WHITE 6 <br /> BLACK 1�-� <br /> - I GASOLINE DISPENSER 8. ALL CABINET PENETRATIONS MUST ENTER <br /> (ISIM) NOTE: THROUGH A PRE-DRILLED CONDUIT <br /> ---DATA DISCONNECT KNOCKOUT. <br /> BLACK RED 1. HUB, ROUTER AND CABLES BY NCR INSTALLER DEVICE <br /> 794380-303 _- - BLACK VAG 2. EDH, D-BOX, CRIND CONTROL CABLE, GAS CONTROLLER CABLE RECEPTACLE °0 <br /> WHITE + LO <br /> PRODUCT AND D-BOX CABLE INSTALLED BY THE GILBARCO AUTHORIZED Y <br /> RED (SSIPM) SERVICE CONTRACTOR O <br /> BLACK VAC <br /> + WHITE WHITE SENSOR GAS' CONTROLLER DIAGRAM <br /> m ti rn <br /> cr, Ch <br /> RED BLACK . - I P � � co <br /> Q <br /> VAC BLACK 2 m <br /> FLOAT NTS a n o <br /> VENT RED • - BLACK RED W a u <br /> SSIPM VAC <br /> ( ) VAC BLACK F7� BLACK FLOAT TANK SUMPS o0 Q f- �p Y <br /> SENSOR WHITE WHITE RED (SSIPM) 0 W <br /> BLACK VAC 0 c) � U <br /> • WHITE SENSOR SURGE SUPPRESSOR 00 <br /> - + WHITECD <br /> -- RED BLACK � z C� <br /> VAC <br /> RED <br /> EDK07 I RJ45 ENDS W17-ELEVEN N � 51 <br /> FLOAT • - - m IDG RECEPTACLE FOR <br /> PRODUCT RED_ BLACK EDH AND SURGE KIT AND GENDER -0 <br /> RED MENDER CONNECTORS. W m � <br /> VAC p SUPPRESSOR W <br /> (SSIPM) VAC SLACK • BLACK 1"CONDUIT WITH 4 CAT.6 <br /> SENSOR WHITE WHITE `�" I FLOAT VAPOR AND UDC D CABLES FROM COUNTER ] U <br /> - - RED (SSIPM) TO BACKROOM, TANKCo <br /> E • VAC STATION RIS ROUTER <br /> BLACK MONITOR D.BOX AND WORK ,0 d V <br /> 7 WHITE SENSOR I PORT#6 CAR WASH ST <br /> crS _ __ __.-_ _ WHITE <br /> -- RED BLACK I PORT#5 TANK MONITOR t0 <br /> � vomc- � <br /> CAT. 6 Cjuoso � 000E <br /> VAG • PORT#4 PRICE SIGN CONTROLLER a ami m a © U U a <br /> rn BLA..K <br /> FLOAT MAG RROBE <br /> TURBINE FILL —I— _ -0 2 p 5 a c o5. ' w 'D <br /> o <br /> VAC RED Bt�CK I NOTE: IN EXISTING STORES,VERIFY 1: � 2 a� o� <br /> SUMP St�,cK (PITIM} PORT#3 PIN P/�lD c �,. <br /> • � on � � rte._ rnmcn <br /> (SSIPM) SENSOR WHITE WHITE -�- - THE EXISTENCE OF A CAT6 CABLE ' .°' ° <br /> PORT#2 PIN PAD#2 m m � c Y �- E- <br /> 846390-107 ENHANCED PORT#1 PIN PAD#1 WITH RJ45 CONNECTORS ON EACH <br /> c3 MAG PROBE '}' WHITE <br /> UNUSED PUMP LOOPS 10 0 2 - � - o E <br /> DISPENSER HUB END OF THE CABLE AS THE N� 0,--0 <br /> �Q�°�-�� o� � �� <br /> z BLAc CONNECTION FROM THE L (� <br /> (PITIM) L -__ __ �_ <br /> __ — AUTOMATIC TANK MONITOR(ATG) D°?a °= �, = o 0 m <br /> PUMP LOOP#2 TO D. BOX 17-32 MPDS. CAT.6 TO THE IN STORE PROCESS OR (ISP}. °' <br /> o� Eas2n � �s a.�.io <br /> p� o <br /> PUMP LOOP#1 TO D. BOX 4-16 MPDS, CAT.6 <br /> 846390-107 <br /> WHIT • + GILBARCO <br /> ROUTER <br /> eapFFSSIc. <br /> — — WIRE TYPES AND SIZES ETHERNET Cisco 42 <br /> �- TABLE 1 CONNECTION SRK/JUNIPER(4 CABLES �p2` <br /> CABLE TYPE PROBE OR SENSOR PASSPORT CAT.6 FROM GILBARCO FROM JUNIPER) GOT, GOT m <br /> POWERED BY ROUTER TO RIS JUNIPER EXTRA AND 2 SPARES $t9T <br /> � BELDEN 88760 PROBE, SUMP, LIQUID,AND VACUUM SENSOR CYBERA ROUTER, <br /> 12 AWG THWN AC POWER TO CONSOLE <br /> N� <br /> ATF�F CA1.IF��� <br /> 0 <br /> I ENHANCED DISPENSER <br /> MONITORING WIRING SCHEMAT 3NTSHUB- <br /> SITESHEET: <br /> N <br /> F- ,P <br /> Z Q <br /> G12 . 0 <br /> U w <br /> CID <br /> � <br /> FUELING - USA <br /> CD <br /> � a <br />