My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
INSTALL_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2021 2:36:18 PM
Creation date
12/7/2020 10:52:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2020
RECORD_ID
PR0231074
PE
2351
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J Q Q Q U IN Environmental Health Department <br /> C O U N T Y Time In: <br /> Time Out: <br /> Greorness grows here. <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: 7-ELEVEN INC#20632 Date: 12/09/2020 <br /> Address: 4627 DA VINCI DR , STOCKTON 95207 <br /> Requestor: NICHOLAS ROWE, LC SERVICES Telephone: (559)892-5287 <br /> Program Element: 2303-UST/PIPING INSTALLATION Request#: SR0079419 <br /> Inspection Type: 131 -UST INSTALLATION INSPECTION <br /> Onsite Service Technician: Tim Hardin ICC Service Tech/Installer Exp. Date: 06/28/2021 <br /> Manufacturer training: NOV, 04/25/21 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site to witness primary piping test. <br /> 1. Witnessed soap testing on all primary piping. <br /> 2. Witnessed 1 hour pneumatic pressure test in accordance with manufacturer's installation instructions. <br /> -there was a drastic decrease in pressure for the 87 chase pipe. The installer addressed this by applying additional sealant for <br /> the 87 chase pipe. <br /> -there was a slight increase in pressure for the 91 chase pipe. The installer stated the slight increase in pressure may be due <br /> to the increase in temperature from the sun. <br /> -there was a slight increase in pressure for the 87 product pipe. The installer stated the slight increase in pressure may be due <br /> to the increase in temperature from the sun. <br /> 3. The 1 hour pneumatic pressure test was performed a second time. All components passed. <br /> 4. Verified functionality of all gauges. <br /> To minimize person to person contact EHD is choosing to write the name of the person receiving the report instead of having <br /> them sign. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Emailed to Larry Carpenter, Contract <br /> EH Specialist: VICKY VANG-LEE Phone: (209)616-3028 <br /> FA0002541 SR0079419 SC131 12/09/2020 <br /> EHD 23-01 Rev.09/16/2020 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.