My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
INSTALL_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2021 2:36:18 PM
Creation date
12/7/2020 10:52:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2020
RECORD_ID
PR0231074
PE
2351
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Vaporless 99 LD-2000 Addendum <br /> 2.0 Background <br /> The federal Environmental Protection Agency (EPA) has provided a series of documents5 which <br /> describe the procedures which are to be used to verify that leak detection equipment meets the <br /> performance requirements of the Federal Register.6 At the minimum, a leak detector which is <br /> capable of detecting leaks of 3.0 gallons per hour (gal/hr) or larger on an hourly basis must be <br /> installed on all pressurized piping. Other options include the use of equipment which is capable <br /> of detecting 0.20 gal/hr on a monthly basis or an annual test capable of detecting leaks of 0.10 <br /> gal/hr. The probability of detecting a leak of stated size must be 95% or greater with a <br /> probability of a false alarm(declaring a tight line to be leaking) of no more than 5%. <br /> To provide a mechanism for achieving compliance with the requirements for leak detection on <br /> pressurized piping, the EPA has developed a test protocol "Standard Test Procedures for <br /> Evaluating Leak Detection Methods: Pressurized Pipeline Leak Detection Systems", <br /> EPA/530/JST-90/010, September, 1990. Testing conducted for this addendum were evaluated <br /> according to the EPA protocol with the exception of the number of tests conducted. <br /> The EPA protocol does not require that systems be tested on both rigid and flexible pipelines. <br /> However, some federal, state, and local regulators have required additional testing on flexible <br /> pipelines for systems that were originally evaluated on rigid pipelines. This addendum includes <br /> the results of testing conducted on flexible piping in response to those regulator's requirements. <br /> 5"Standard Test Procedures for Evaluating Leak Detection Methods," EPA/530 <br /> UST90/001-7, March to October 1990. Seven different procedures were developed for <br /> different leak detection methods and released between March and October 1990. <br /> 6 40CFR Part 280, Subpart D. <br /> Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.