My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
INSTALL_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2021 2:36:18 PM
Creation date
12/7/2020 10:52:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2020
RECORD_ID
PR0231074
PE
2351
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
j.}J Y {� Q <br /> IIOUVNTY �v <br /> Environmental Health Department <br /> F. SYSTEM PIPING CONTINUED: <br /> Check Code <br /> Box Section <br /> HSC Piping compatible with material intended to be stored. <br /> 25290.1 c 1 <br /> 25290.2 c 1 <br /> 23 CCR <br /> 2631(b) Design and construction of piping approved by independent testing organization(e.g. UL). <br /> Piping, including vent lines, sloped toward tank(s)with minimum 1/8 inch slope per 1 foot of run. <br /> HSC <br /> 25290.1 k Vapor recovery, fill riser, and vent line piping are secondarily contained. <br /> 25290.2�c3&Q) <br /> G. OVERSPILL/ OVERFILL PREVENTION: <br /> Check Code <br /> Box Section <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> 2635(b) Manufacturer Model Z ©cam <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> ❑Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br /> ❑ 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> ❑ Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Providepositive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> ManufacturerModel q LSa— <br /> H. CORROSION PROTECTION: <br /> Check Code <br /> Box Section <br /> Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) 12 <br /> FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> 23 CCR ❑ Steel tank with field installed cathodic protection or impressed <br /> 2635(a)(2) <br /> current <br /> Tie-downs,when used, constructed of non-corrosive material or coated steel. <br /> 7of8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.