GENERAL NOTES: <br /> A. ALL REFRIGERATION DEMOLITION TO BE COMPLETED IN ACCORDANCE <br /> TO SPEC SECTION 24 0150 (15601) REFRIGERATION EQUIPMENT <br /> RECOVERY AND DEMOLITION INSTRUCTIONS. <br /> B. RETAIN ALL REFRIGERATED CASE TRIM AND FASCIA TO BE RE-USED. <br /> C. COORDINATE DISPOSAURECOVERY OF UNUSED REFRIGERATION <br /> ASSETS WITH TARGET OSR. <br /> D. VERIFY WITH EMC AND THE REMS DRAWINGS FOR THE RE-USE OF ANY <br /> REMS PANELS. PANELS THAT ARE NOT BEING RE-USED SHALL BE SENT TARGET) <br /> BACK TO EMC. <br /> E. CONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH <br /> KNOWLEDGE OF ALL DRAWINGS, SPECIFICATIONS AND EXISTING 1000 NICOLLET MALL <br /> CONDITIONS FOR BIDDING PURPOSES. FAILURE TO ACQUAINT MINNEAPOLIS, MN 55403 <br /> THEMSELVES WITH THIS KNOWLEDGE DOES NOT RELIEVE THE <br /> RESPONSIBILITY OF PERFORMING THEIR WORK PROPERLY. <br /> F. ARRANGE ALL REQUIRED WORK TO KEEP DISRUPTIONS TO STORE <br /> OPERATIONS TO A MINIMUM. COORDINATE ANY DISRUPTIONS WITH <br /> TARGET PROJECT MANAGER, OSR, AND STORE MANAGER. HENDERSON <br /> G. CONCRETE CUTS SHALL BE STRAIGHT AND CLEAN. REPLACE SLAB ENGINEERS <br /> WITH CONCRETE FLUSH AND SMOOTH WITH ADJACENT, ALL SLAB r_i <br /> WORK SHALL BE COMPLETED BY GENERAL CONTRACTOR. 8345 LENEXA DRIVE, SUITE 300 <br /> LENEXA, KS 66214 <br /> H. FIELD VERIFY LOCATIONS AND QUANTITY OF ALL EXISTING EQUIPMENT, TEL 913.742.5000 FAX 913.742.5001 <br /> FIXTURES, DUCTWORK, AND PIPING NECESSARY TO COMPLETE SCOPE <br /> OF WORK. WWW.HENDERSONENGINEERS.COM <br /> J.; <br /> INDICATES TO BE REMOVED. ALL REMOVED 1950001330 <br /> EQUIPMENT TO BE DISPOSED OF BY CONTRACTOR <br /> UNLESS NOTED AS RELOCATED/RETAINED IN <br /> DEMOLITION NOTES. <br /> KEYNOTES: <br /> 1� REMOVE EXISTING REFRIGERATED CASE, CONDENSATE PIPING AND ALL <br /> ACCESSORIES. REFRIGERATED CASE WILL NOT BE REUSED. <br /> 2� EXISTING REFRIGERATED CASE TO REMAIN, <br /> NOT USED. <br /> ® CAP AND SEAL REFRIGERATION PIPING FOR REUSE. <br /> EXISTING REMS PANEL TO REMAIN. <br /> 10 9 , <br /> REFRIGERATION SHEET INDEX <br /> RD01 REFRIGERATION DEMOLITION PLANS Date ! NO. Description 1 <br /> R111 REFRIGERATION SYSTEM PLAN <br /> O R401 MARKET AREA CASE SETTING & PIPING PLANS 08/22/19 PERMIT ISSUE <br /> c[ j R511 REFRIGERATION DETAILS <br /> W L 8601 REFRIGERATION SCHEDULES <br /> 8602 REFRIGERATION TITLE-24 <br /> W o i 8621 REFRIGERATION CONTROLS PLANS I __ <br /> i <br /> CONSULTANT QUALITY ASSURANCE REVIEW CONFIRMATION <br /> .,� STAMP € � - <br /> i [] DOCUMENTS REVIEWED 6Y: Hayley Overcash <br /> tt <br /> wE SALES <br /> 102 <br /> ^W REVIEWERS PHONE: 913-742-5427 ; <br /> wC <br /> E? i REVIEWERS E-MAIL: hayley.overcashpa hendersonengineers.com <br /> I <br /> DATE REVIEWED: 07/23/2019 <br /> i -� i <br /> in q <br /> Zw ? <br /> cc <br /> - - - - - -- - - - -- - - - --- - - - - - - - - - - - - -- - - - - - - <br /> - <br /> ..f <br /> I I (E) <br /> (E) RLN2 ! ! <br /> ii Dual-Temp <br /> ' r REUSED <br /> z w <br /> I,« E (E) (E)P5FGN5 E (E) P5FGN5 (E) P5FGN5 <br /> i DUAL TEMP DUAL TEMP i I <br /> E W I A05 REUSED 2 ! A REUSED I (-6-05-) REUSED <br /> MP 2 <br /> (E) RLN5 {E) (E) RLN5 W Si L__ E2 {E) ❑2 (E) (E) RLN5 <br /> A04 REUSED <br /> A04 REUSED A04 REUSED <br /> Li <br /> s <br /> (E) Ir- 2.....-,- � v I I1. <br /> 55 <br /> AB05 E I € L11 E 1QJ Cc <br /> (E) RLN2 <br /> o M. <br /> Dual-Temp I REMS-3 (E) � 4 � <br /> REUSED i s AB02 .� <br /> (E) RLN2 <br /> -# M 38996 ' <br /> 5 I Dual-Temp <br /> REUSED <br /> 0 2 (E) (E) RLN5 L 2 (E) E RL0N5 2 (E) 't F <br /> AB04 ' A03 REUSE A08 REUSED A REUSED 1 <br /> (E) RLNS � ( � i 03 <br /> Dual-Temp I _I <br /> REUSED <br /> i�P2 , (E) (E) RLNS `� (E) (E) RLN5 i (F) (E)RLN5 ` Aug 2 ZOO 9 <br /> A02 REUSED A02 REUSED A02 REUSED <br /> z8 <br /> REMS-4 <br /> � p - E- - � - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - <br /> - - <br /> i <br /> A802 <br /> � <br /> (E) RLN2 <br /> 2 -__.. 4 Dual-Temp <br /> _ <br /> (E) (E)05M-8 (E) (E) 05M-8 (E) (E) 05M-12 i (E) (E) 05M-12 <br /> Z B05 REUSED B06 REUSED 806 REUSED 806 REUSED <br /> U_ s s <br /> W 2 1 (E) (E) 05M-8 .� (E) (E) 05M-8 {E) E 05M 12 2 (E) E 05M-12 _ <br /> 'Q ccIFIE <br /> B04 REUSED 804 REUSED B04 REUSED B04 REUSED W CD <br /> co <br /> gd 2 Cn O) <br /> z W Q <br /> �n <br /> `L.L� Lu <br /> LLJ° (� U <br /> UJ <br /> cc 2 uj F2 E2 <br /> 0 � ; 0 W <br /> 13 I w w s (E) OWIz-8 w I U <br /> REUSED E ^ W <br /> LL <br /> o <br /> �(A01-B <br /> VJ Q I i 7 <br /> gmm.2 I O <br /> 00N <br /> 1, LT) C 1 <br /> mm 9 I <br /> €yW11 <br /> �.) <br /> E <br /> J V] <br /> "w,! UJ I <br /> (E) (E) 05M-12 "2 (E) (E) 05M-8 8 2 i I�I' �� E � Q <br /> W o B07 REUSED % �� { ) (E) 05M-12 �, w <br /> B02 REUSED I (E) 05M-8 BQ2 REUSED W m O <br /> REUSED _— � L41€ W <br /> C - - - - -- - - - - - - - - - - - - - - - - - - - - - - - <br /> T� f - -- - - -- - - - " - -- - <br /> lLj <br /> Project Number T- 1 526 <br /> 1 REFRIGERATION DEMOLITION PLAN Config: RL <br /> SCALE; 3/16"= 1�-0� �� Drawn By <br /> CG <br /> Checked By HARO <br /> REFRIGERATION <br /> DEMOLITION PLANS <br /> NOTE: <br /> LU EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS <br /> FIELD VEISITS RIFY ALDEXiST NG CONDITIONS PRIOR TO SY NOT REFLECT EXACT IUBMITOTING CONDITIONS. <br /> ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY TARGET APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. BIDS. VERIFY CAREFULLY EXISTINGATE <br /> WORK ANDDEMOLITION <br /> - - WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. TRUE NORTH <br /> r <br />