My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0041304
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CEDAR
>
17710
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0041304
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 1:51:32 PM
Creation date
12/10/2020 3:48:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0041304
PE
4370
STREET_NUMBER
17710
Direction
E
STREET_NAME
CEDAR
STREET_TYPE
LN
City
RIPON
Zip
95366-
APN
24514006
ENTERED_DATE
10/5/2020 12:00:00 AM
SITE_LOCATION
17710 E CEDAR LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Supplemental fields
CYEAR
2020
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
March 2, 2021 Lab ID : STK2132060 <br /> San Joaquin Co. Environmental Health Dep Customer : 3-17919 <br /> Quality Control-Inorganic <br /> Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br /> Wet Chem <br /> Nitrate 300.0 (VI 2141048-001) MSD mg/L 40.00 76.4% 85-119 435 <br /> MSRPD m 10.00 1.6% <19 <br /> 300.0 02/11/21:202162MCA CCB mg/L 0.000 0.5 <br /> CCV mg/L 20.00 103% 90-110 <br /> CCB mg/L 0.000 0.5 <br /> CCV m 20.00 103% 90-110 <br /> itrate+Nitrite as N 300.0 02/11/21:201532MCA Blank mg/L ND <0.1 <br /> Nitrate Nitrogen 300.0 02/11/21:201532MCA Blank mg/L ND <0.1 <br /> itrite 300.0 02/11/21:201532MCA Blank mg/L ND <0.5 <br /> LCS mg/L 15.00 103% 90-110 <br /> MS mg/L 30.00 103% 74-126 <br /> (VI 2141023-002) MSD mg/L 30.00 103% 74-126 <br /> MSRPD mg/L 10.00 0.9% <_20 <br /> MS mg/L 30.00 103% 74-126 <br /> (VI 2141048-001) MSD mg/L 30.00 102% 74-126 <br /> MSRPD m 10.00 0.1% 1 <20 <br /> 300.0 02/11/21:202162MCA CCB mg/L 0.000 0.5 <br /> CCV mg/L 15.00 103% 90-110 <br /> CCB mg/L 0.000 0.5 <br /> CCV mg/L 15.00 103% 90-110 <br /> Nitrite Nitrogen 300.0 02/11/21:201532MCA Blank mg/L ND <0.2 <br /> Sulfate 300.0 02/11/21:201532MCA Blank mg/L ND <0.5 <br /> LCS mg/L 50.00 101% 90-110 <br /> MS mg/L 100.0 101% 82424 <br /> (VI 2141023-002) MSD mg/L 100.0 102% 82-124 <br /> MSRPD mg/L 10.00 1.2% :523 <br /> MS mg/L 100.0 98.0% 82-124 <br /> (VI 2141048-001) MSD mg/L 100.0 98.8% 82-124 <br /> MSRPD mg/L 10.00 0.6% 523 <br /> 300.0 02/11/21:202162MCA CCB mg/L 0.214 0.5 <br /> CCV mg/L 50.00 102% 90-110 <br /> CCB mg/L 0.199 0.5 <br /> CCV mg/L 50.00 104% 90-110 <br /> MBAS 5540C 02/12/21:202357jba CCB mg/L -0.0195 0.25 <br /> CCV mg/L 1.000 102% 90-110 <br /> CCB mg/L -0.0113 0.25 <br /> CCV I m 1.000 102% 1 90-110 <br /> MBAs Extraction 5540C 02/12/21:201586jba Blank mg/L ND <0.1 <br /> LCS mg/L 0.5000 102% 86-114 <br /> BS mg/L 0.5000 100% 86-114 <br /> BSD mg/L 0.5000 102% 86-114 <br /> BSRPD mg/L 0.5000 2.0% <5 <br /> Definition <br /> ICB :Initial Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> BS :Blank Spikes-A blank is spiked with a known amount of analyte.It is prepared to verify that the preparation process is not <br /> affecting analyte recovery. <br /> Page 8 of 9 <br />