Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
RIVER
>
222
>
1600 - Food Program
>
PR0546365
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2021 8:09:40 AM
Creation date
12/17/2020 3:21:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546365
PE
1624
FACILITY_ID
FA0026275
FACILITY_NAME
KLEAN EATZ MARKET & BAKERY
STREET_NUMBER
222
Direction
W
STREET_NAME
RIVER
STREET_TYPE
RD
City
RIPON
Zip
95366
CURRENT_STATUS
01
SITE_LOCATION
222 W RIVER RD
P_LOCATION
05
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
±42'-7 FLOOR PLAN KEYNOTES: REVISIONS <br /> 18'-6" 24 <br /> - -'-1-" - - - - - - - - 1. EXTERIOR WALL-EXISTING-PROVIDE R-19 BATT INSULATION FULL <br /> 10 lo I± ± <br /> HEIGHT OF WALL AS NECESSARY <br /> 2. EXISTING DEMISING WALL-2 X 6 AT 16"O.C.-PROVIDE R-19 BATT INSULATION FULL <br /> 15 22 HEIGHT AS NECESSARY-PROVIDE 2 X FIRE BLOCKING IN CONCEALED SPACES OF <br /> 12 20 I 14 STUD WALLS AND PARTITIONS,INCLUDING FURRED SPACES,AT THE CEILING AND <br /> 4 FLOOR LEVELS AND AT 10 FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL PER <br /> 17 CBC SECTION 718.2.1 <br /> 3. EXISTING POST-PREP AND PAINT <br /> 15 4. LINE OF EXISTING AWING ABOVE <br /> 23 21 13 o O 5. EXISTING HOSE BIB <br /> 1 6. EXISTING GAS METERS <br /> + O o 57 7. 2 X 4 STUDS AT 16"O.C.AT INTERIOR WALLS-PROVIDE 2 X FIRE BLOCKING IN <br /> CONCEALED SPACES OF STUD WALLS AND PARTITIONS,INCLUDING FURRED SPACES, <br /> AT THE CEILING AND FLOOR LEVELS AND AT 10 FOOT INTERVALS BOTH VERTICAL AND <br /> 0 o QHORIZONTAL PER CBC SECTION 718.2.1 -SEE DETAILS 1 THROUGH 4/AD2 <br /> 13 :o6'-6" 13'-4" 5 <br /> 56 8. 2 X 6 STUDS AT 16"O.C.AT INTERIOR WALLS-PROVIDE 2 X FIRE BLOCKING IN <br /> CONCEALED SPACES OF STUD WALLS AND PARTITIONS,INCLUDING FURRED SPACES, <br /> 50 I 7 48 HB AT THE CEILING AND FLOOR LEVELS AND AT 10 FOOT INTERVALS BOTH VERTICAL AND <br /> O HORIZONTAL PER CBC SECTION 718.2.1 -SEE DETAILS 1 THROUGH 4/AD2 <br /> 9. PROVIDE BLOCKING IN WALLS FOR WALL MOUNTED SHELVING AND EQUIPMENT SEE THIS DOCUMENT,AND THE IDEAS AND DESIGNS <br /> 47 I I DETAIL 8/ADl -VERIFY LOCATIONS WITH TENANT INCORPORATED HEREIN,AS AN INSTRUMENT OF <br /> 60 10. FRAMED OPENING PROFESSIONAL SERVICE, IS THE PROPERTY OF <br /> 64 " <br /> co api" AND IS NOT TO BE USED, IN WHOLE OR IN <br /> 11. INDICATES SOFFIT ABOVE-SEE REFLECTED CEILING PLAN AND DETAIL 1/AD3 PART,FOR ANY OTHER PROJECT WITHOUT <br /> SEATING _ _ I - 12. DIMENSIONS ARE TO FACE OF STUDS-TYPICAL U.N.O. WRITTEN AUTHORIZATION. <br /> Z102 I I I ® 49 I 6' 1" 13. EXISTING STOREFRONT ASSEMBLY-MODIFY AS NECESSARY FOR NEW DOOR AND <br /> CASHIER GLAZING-SEE STOREFRONT SCHEDULE <br /> c) MIN. I 62 48 1 10 14 DOOR OR NEW EXISTING PAIR FOPEEN NG VERIFY W T OWNER STOREFRONT DOORS TO BE REMOVED-OPTION TO RE-USE SAME PLANNING <br /> CN <br /> - 15. NEW STOREFRONT DOOR-SEE DOOR SCHEDULE <br /> 49 � � ARCHITECTURE <br /> �o 16. DOOR AND FRAME-SEE DOOR SCHEDULE <br /> 24 17. EXISTING CONCRETE WALK <br /> co - - - - J I I I 18. EXISTING DOOR TO REMAIN IN CLOSED/LOCKED POSITION AND PULLS/LATCHES TO BE <br /> 00 blElo <br /> REMOVED <br /> Wd6 <br /> 54 19. PROVIDE A MINIMUM OF 12"CLEAR AT INTERIOR AT STRIKE SIDE OF OUTSWINGING <br /> 9'-0" 1'b" 23'-3" L EXTERIOR DOORS-TYPICAL <br /> Q o 20. MIN.60"x 60"CLEAR AND LEVEL LANDING AT EXTERIOR DOORS <br /> co <br /> } 62 I I T 21. PROVIDE A MINIMUM OF 18"CLEAR AT STRIKE SIDE OF INTERIOR DOORS AND 24"AT <br /> EXTERIOR DOORS-SEE DETAIL 10/ADI -TYPICAL <br /> Q <br /> - - - - - - J 22. PROVIDE SIGN ABOVE DOOR TO READ'THIS DOOR TO REMAIN UNLOCKED WHEN THIS <br /> m F SPACE IS OCCUPIED"IF NOT EXISTING PER CBC 1010.1.9.3 ITEM 2 ID <br /> 23. INDICATES INTERNATIONAL SIGN OF ACCESSIBILITY(MIN.6 X 6)-MOUNT ADJACENT <br /> r I 48 24 7 TO THE LATCH,OUTSIDE OF THE DOOR,OR ON THE NEAREST ADJACENT WALL OR ARCHITECTURE PLUS INC. <br /> Lu GLAZING-MOUNTING HEIGHT SHALL BE 60 INCHES ABOVE THE FINISH FLOOR TO <br /> L - - - N THE CENTER LINE OF SIGN-PER CBC I IB-703.7.2.1 -SEE DETAIL 14/ADI 4335-B NORTH STAR WAY <br /> U 24. SALES COUNTER-PROVIDE 36"MINIMUM WIDTH AT+34"MAX.HEIGHT COUNTER MO D ESTO, CA 95356 <br /> SPACE TO BE ACCESSIBLE <br /> 29 U <br /> 12 POS M Lu MARKET 2 25. MERCHANDISE SHELVING BY TENANT ph. 209.577.4661 <br /> J 26. FLOOR SINK-SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS <br /> - - - - - - 101 1 fx. 209.577.0213 <br /> 1 1 OI 27. MOP SINK -SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS <br /> 00 28. HAND SINK-SEE EQUIPMENT PLAN AND PLUMBING DRAWINGS FE I I www.apiarc.com <br /> 3 29. REFRIGERATED CASE-SEE EQUIPMENT PLAN <br /> 0 30 <br /> 30. CAFE EQUIPMENT-SEE EQUIPMENT PLAN <br /> 63 5-2" e 6-0" e ol 6-0" <br /> 43 31. FOOD PREP EQUIPMENT-SEE EQUIPMENT PLAN <br /> D <br /> 31 32. MANUFACTURED REFRIGERATED WALK-IN COOLER WITH 3070 METAL DOORS-SEE <br /> Lu EQUIPMENT PLAN AND MECHANICAL DRAWINGS <br /> 1 Q 33. MINIMUM 30 WIDE X 48 DEEP CLEAR FLOOR AREA FRANK C.BOOTS <br /> U <br /> ,� SMITH <br /> \ 29 w 34. WATER HEATER SEE PLUMBING DRAWINGS JOSEPH L. <br /> RODNEY C.ALONZO <br /> m p 35. FIRE EXTINGUISHER AND CABINET-TYPICAL-VERIFY LOCATIONS WITH FIRE MARSHAL <br /> \ / 42 / PROVIDE 1) 2A:10BC FIRE EXTINGUISHER EVERY 75'WALKING DISTANCE THAT IS NOT A R C H I T E C T S <br /> y 25 I MORE THAN 4'FROM THE FLOOR- FIRE EXTINGUISHER TO BE LOCATED NEXT TO MAN <br /> / wz DOOR-DISPLAY A CURRENT STATE FIRE MARSHAL SERVICE LABEL PER CFC Q <br /> m 25 ui <br /> 36. DASHED LINE INDICATES APPROXIMATE THICKNESS OF WALL FINISH V <br /> 37. 1-1/2"X 1-1/2"X 48"X 20 GA STAINLESS STEEL CORNER GUARD ON OUTSIDE CORNERS <br /> J c -TYPICAL-VERIFY WITH TENANT <br /> cot - - m N 38. ACCESSIBLE SINGLE-ACCOMMODATION RESTROOM-SEE SHEET A4.0 <br /> 33 I / N 51 3 39. ACCESSIBLE LAVATORY-PROVIDE BRACKETS AND BLOCKING AS NECESSARY <br /> FOR SUPPORT-SEE PLUMBING DRAWINGS AND DETAILS 1 &2/ADI <br /> T �I � a <br /> 44- - J m I w j 40. ACCESSIBLE WATER CLOSETS-SEE PLUMBING DRAWINGS AND DETAILS 1 &3/ADI <br /> �j Q `� 41. INDICATES AREA OF NEW 4"REINFORCED CONCRETE SLAB-REINFORCING AND W V <br /> 1+1LJK / T I u M +i CONTROL JOINTS TO BE SAME AS NOTED IN SHELL BUILDING CONSTRUCTION <br /> \ „ 3 29 U DOCUMENTS N W <br /> Lu <br /> m 0 I 42. INDICATES APPROXIMATE LOCATION OF EXISTING CONCRETE SLAB TO BE SAWCUT W <br /> ADJACENT / N 25 ADJACENT AND REMOVED FOR NEW UTILITIES-FIELD VERIFY LOCATION-FILL AND COMPACT ` y <br /> / / M TRENCH AND PROVIDE CONCRETE PATCH-FINISH TO MATCH ADJACENT CONCRETE ND <br /> TENANT o TENANT DCROOR NGSAND OEXISTI ON OFCONSTRUCTION SAWCUT <br /> WITH E E CTRLDETAL A DI MECHANICAL W 0 <br /> 0 2 43. LINE OF EXHAUST HOOD CANOPY WITH ONE-HOUR RATED DUCT SHAFT-SEE O <br /> b i / 9 MECHANICAL DRAWINGS Z <br /> 44. PROVIDE A TYPE K FIRE EXTINGUISHER WITHIN 30 FEET OF THE HOOD PER 904.11.2 CFC /� W <br /> 45. WALL TO HAVE+8'-0"STAINLESS STEEL FINISH AT COOKLINE/EXHAUST HOOD AREA- \� > <br /> SEE FINISH SCHEDULE W 11-- I= <br /> 46. EMPLOYEE LOCKERS MIN 1%LOCKERS TO BE H.C.ACCESSIBLE(DENOTED W/6"x b" Z <br /> Q I w BLUE STICKER) WITH A MIN REACH HEIGHT OF 9"OR MORE BUT NOT MORE THAN H <br /> Q 54"A.F.F.-PROVIDE BACKING AS REQUIRED-MOUNT LOCKERS TO WALL 6"A.F.F.- Q W <br /> o I 60 U PROVIDE CONTINUOUS FLOORING AT LOCKER AREA AND COVE UP WALL MIN.5"-BY Z 3.0 <br /> slz TENANT <br /> O i OVEN O 29 w 47. CUSTOMER SEATING AREA-TABLE AND CHAIRS PROVIDED BY OWNER-PROVIDE A u.l N <br /> LL Q MINIMUM OF AT LEAST 5%OF SEATING SPACES TO BE ACCESSIBLE SEATING PER CBC N <br /> Lu Lu IIB-226.1 <br /> U I 63 48. POINT OF SALE EQUIPMENT-PROVIDE POWER AND DATA-SEE ELECTRICAL <br /> r DRAWINGS <br /> 0 i 59 1 <br /> 0 CO 49. INDICATES MERCHANDISE BINS-PROVIDED BY TENANT O <br /> z BAKERY 15'-5" 5'-10" 3'-6" 5'0" 50. 6X6 POST WITH ROOF STRUCTURE OVER BIN DISPLAY-SEE DETAIL 15/AD2 a <br /> w I / - - - - - - - - - - - - - - - - - - 51. WALL MOUNTED AWNING OVER REFRIGERATED CASES-INSTALL 1"ABOVE CASES, <br /> 42 o VERIFY WITH OWNER-FRAME TO BE 12"SQUARE WELDED STEEL TUBE-PROVIDE 6X6 <br /> 28 BLOCKING TOP AND BOTTOM IN WALL WITH A35 AT EACH END OF TOP AND BOTTOM <br /> -ATTACH FRAME TO BLOCK WITH 1/4"LAG BOLTS MIN.4"EMBEDDED-ROOF PITCH AT <br /> IIT6TL 51 8 6:12 WITH CORRUGATED METAL SHEET PANEL-VERIFY WITH OWNER <br /> L - _ _ - J 0 52. ELECTRICAL PANELS-TYPICAL-MAINTAIN CLEAR WORKING AREA-SEE ELECTRICAL <br /> 65 ° DRAWINGS <br /> 33 8FT MULTI-DECK CASE 8FT MULTI DECK CASE in 10 <br /> 42 X 72 PREP TABLE <br /> 46 35 53. FLOOR DRAIN-SEE PLUMBING DRAWINGS <br /> 54. THERMOSTAT-MOUNT AT+44"MAXIMUM-SEE MECHANICAL DRAWINGS <br /> M I _ 3 55. SIGN TIMECLOCK-SEE ELECTRICAL DRAWINGS <br /> O4 12 56. PROVIDE TACTILE EXIT/ROUTE SIGN AT EXIT DOOR AS REQUIRED-SEE DETAILS 5/ADI <br /> J - 2-0" 9 21 16 57. INDICATES AREA OF GROCERY CART STORAGE <br /> \ OO b-. <br /> 16 / I 58. DASHED LINE INDICATES FRP ON SCULLERY/PREP WALLS-SEE FINISHED SCHEDULE <br /> 59 I RESLO <br /> TRO <br /> v <br /> 59. DASHED LINE INDICATES SUBWAY TILE ON WALLS IN CAFE AND BAKERY-SEE FINISHED <br /> O I \ \ 26 52 7 I / 109 <br /> 53 3 - C? SCHEDULE AND DETAIL 10&12/AD2 <br /> O I O� 5 0 36 60. BASE CABINET WITH SOLID SURFACE COUNTERTOP AND OPEN SHELVES BELOW- <br /> L_ 58 FD 8 1 38 VERIFY WITH OWNER <br /> Cie \ 10 / / 39 bl Z <br /> . BAKERY DISPLAY CASE-SEE EQUIPMENT PLAN Q <br /> z26 26 37 SCULLERY / PREP. I H 62. 30"X 48"CLEAR FLOOR SPACE FOR PARALLEL APPROACH <br /> ALL <br /> Q IO\ 31 \ 106 41 37 I. / 107 40 O 1 63. FLOOR SURFACES TO BE SLIP RESISTANT PER CBC 11 B-302 O <br /> _ _ _ MINIMUM INSULATION O <br /> U \ 5'-0" 55 REQUIREMENTS 64. BENCH SEATING-BY OWNER U- <br /> p 26 63 \ a3il s 65. LINE OF FLOOR FINISH TRANSITION <br /> z37 37 co 66. EXISTING DOOR AND FRAME <br /> Cie"' x EXTERIOR WALLS: R-19 BATT <br /> 24x72 N <br /> EXTERIOR WALL INSULATION TO BE <br /> w / o \ \ INSTALLED WITH BUILDING SHELL <br /> Z 63 \ STORAGE DEMISING WALL: R-19 BATT <br /> Y' / QO O 34 O 108 \ Fn ATTIC: R-30 BATT(AT TOP CHORD) <br /> - - - 19 "' ATTIC INSULATION TO BE INSTALLED <br /> WALK-IN COOLER / m L L- _-__-__� - WITH BUILDING SHELL SYMBOL LEGEND <br /> 105 / <br /> 18 O 1 *VERIFY REQUIREMENTS WITH ENERGY CALCULATONS O DOOR SYMBOL-SEE DOOR SCHEDULE SHEET A5.0 <br /> o <br /> bb O WINDOW SYMBOLS-SEE WINDOW SCHEDULE SHEET A5.0 N <br /> a3il s <br /> M <br /> m . - <br /> Ao <br /> lsxso 4 101 ROOMNUMBER-SEE FINISH SCHEDULE A5.0 0 <br /> NOTE: C) <br /> O 1. ELECTRICAL CIRCUIT BREAKERS SHALL BE LEGIBLY AND DURABLY MARKED.PER 0 <br /> 20 CFC 605.3.1 DATE : FEBRUARY 2020 <br /> 2. PROVIDE 2A10-BC WITHIN 750F EXITS AND 3,000 S.F.IN GENERAL USE AREAS. JOB NO. : 19-130 N <br /> 6 FIRE MARSHALL TO DETERMINE LOCATIONS WITH EACH TENANT a <br /> IMPROVEMENT. WALL LEGEND DRAWN : A. ZAPIEN <br /> a <br /> 3. ALL FIRE BARRIERS,FIRE PARTITIONS,SMOKE BARRIERS,SMOKE PARTITIONS, CHECKED : J. SMITH <br /> FLOOR PLAN AND ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR ® STUD WALL SHEET <br /> PENETRATIONS SHALL BE PERMANENTLY IDENTIFIED WITH SIGNS OR <br /> STENCILING THAT SHALL COMPLY WITH THE FOLLOWING: <br /> SCALE: 1/4"= U-0" A. SIGNS OR STENCILING SHALL SHALL BE LOCATED IN ACCESSIBLE EXISTING WALL o <br /> FLOOR AREAS: 3,138 S.F. CONCEALED FLOOR,FLOOR-CEILING AND ATTIC SPACES. o <br /> B. SIGNS OR STENCILING SHALL BE LOCATED WITHIN 15 FEET OF THE <br /> END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET 2 <br /> MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION. cm <br /> C. LETTERING SHALL BE NOT LESS THAN 3"IN HEIGHT WITH A o <br /> MINIMUM STROKE OF 3/8"IN A CONTRASTING COLOR WITH THE NOTE: PROVIDE R-1 1 SOUND ATTENUATING BATTS AT ALL RESTROOMA21 o <br /> NORTH WORDING:"FIRE/SMOKE BARRIER-ALL OPENINGS/ WALLS AND CEILING o <br /> PENETRATIONS SHALL BE PROTECTED". <br /> P <br /> api COPYRIGHT 2019 <br />