My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
RIVER
>
222
>
1600 - Food Program
>
PR0546365
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2021 8:09:40 AM
Creation date
12/17/2020 3:21:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546365
PE
1624
FACILITY_ID
FA0026275
FACILITY_NAME
KLEAN EATZ MARKET & BAKERY
STREET_NUMBER
222
Direction
W
STREET_NAME
RIVER
STREET_TYPE
RD
City
RIPON
Zip
95366
CURRENT_STATUS
01
SITE_LOCATION
222 W RIVER RD
P_LOCATION
05
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS <br /> (e)MAIN SERVICE )PL)) <br /> TO T–BAR CHANNEL FASTEN BAR HANGER <br /> RECESSED FIXTURE — — — — — — — — — — — — — — — — PANEL <br /> FASTENED TO BAR HANGER WITH SHEET METAL SCREWS. <br /> (e)1600A-120/208V, 30, 4W BUS LOCATION HALL TITLE 24 CATEGORY: LIGHTS <br /> (2 SCREWS PER END PER TOTAL KVA 3 CONNECT AMPS: 8.3A <br /> SLIDE APART BAR HANGER HANGER) I (e)1600/3 MOUNTING FLUSH VOLTAGE 120/208V, 30, 4W <br /> M BUSSING 100A ❑ MCB ® MLO FEEDER Z SEE ONE LINE DIAGRAM <br /> �EEE4T-BAR CHANNEL A.I.C. 18000 ❑ EXISTING <br /> DESCRIPTION LOAD BRKR BRKR LOAD DESCRIPTION <br /> TRIMACOUSTIC SEATING LIGHTING 654 20/1 1 2 20/1 SPARE <br /> CEILING TILE I (e)400A FUSE <br /> CASHIER LIGHTING 300 3 4 <br /> MARKET LIGHTING 1098 5 6 <br /> BAKERY/HALL/RR LTG 930 7 1 8 <br /> (e)400A-120/208V, 30, 4W BUS SPARE 9 10 THIS DOCUMENT,AND THE IDEAS AND DESIGNS <br /> MOUNTING DETAIL: RECESSED FIXTURE TYPE „C„ 1 1 12 INCORPORATED HEREIN,IS AN INSTRUMENT OF <br /> PROFESSIONAL SERVICE, IS THE PROPERTY OF <br /> JSCALE: N.T.S. I 13 14 PART, FOR ANY OOTHER PROJECBE USED, T1WITHOLU OR IN 15 16 WRITTEN AUTHORIZATION. <br /> 4-1 200 100 17 18 <br /> 607 19 20 <br /> L - - - - _ _ _ _ _ 21 22 PLANNING ■ ■ ■ <br /> TO UTILITY 23 24 ARCHITECTURE ■ ■ ■ <br /> 25 26 ■ ■ <br /> 0 0 4 27 28 <br /> c z z -- z 29 30 <br /> �i <br /> 0 .q- 31 32 <br /> 00 <br /> 0 33 34 <br /> 35 36 <br /> 37 38 13 <br /> 39 40 <br /> 41 142, ARCHITECTURE PLUS INC. <br /> PANEL PANEL PANEL 2982 VA TOTAL 4335-B NORTH STAR WAY <br /> "L" "K V$ "W" MODESTO, CA 95356 <br /> ph. 209.577.4661 <br /> PANEL <br /> "K 1 fx. 209.577.0213 <br /> LOCATION HALL TITLE 24 CATEGORY: EQUIPMENT www.apiarc.com <br /> TOTAL KVA 44 CONNECT AMPS: 123A <br /> ONE LINE DIAGRAM MOUNTING : FLUSH VOLTAGE : 120/208V, 30, 4W <br /> BUSSING 200A ❑ MCB Z MLO FEEDER ® SEE ONE LINE DIAGRAM <br /> SCALE: N.T.S. A.I.C. 18000 ❑ EXISTING <br /> FRANK C. BOOTS <br /> EQT# DESCRIPTION LOAD BRKR BRKR LOAD DESCRIPTION EQT# JOSEPH L.SMITH <br /> M1 POS 540 20/1 1 2 20/1 1380 BLENDER C15 RODNEY C.ALONZO <br /> M2 REFRIGERATED CASE 372 3 4 20/1 1200 GAS DECK OVEN B1 A R C H I T E C T S <br /> M2 372 5 6 30 Q <br /> M2 372 7 8 5400 MIXER B5 U <br /> SEE ARCH. DRAWINGS & SPECS M2 372 9 10 3 <br /> ON "HANGER WIRE DETAIL" M2 1 372 11 12 20/1 1200 ICE MAKER B7 <br /> FASTEN #12 SUSPENSION WIRE FOR ANCHORAGE DETAIL. M2 372 13 14 40 6344 DISH WASHER S3 <br /> AT 2 DIAGONAL CORNERS OF PROVIDE 2 TAUGHT WIRES AT p <br /> EACH 4' LAY—IN FIXTURE & DIAGONAL CORNNERS FOR FIXTURES M5 BAKERY DISPLAY CASE 120 15 16 2 <br /> od <br /> TO STRUCTURAL MEMBER THAT WEIGHS 56LBS OR LESS C2 POS 180 17 18 20/1 504 AIR CURTAIN S8 W <br /> U <br /> PROVIDE 4 TAUGHT SUPPORT <br /> C2 PIZZA WARMER 1416 19 20 100 WH-1 N :* <br /> WIRES, ONE AT EACH CORNER C3 PIZZA PREP TABLE 468 1 21 22 SPARE Lu S <br /> FOR FIXTURES THAT WEIGH Q > H <br /> INTEGRAL EARTHQUAKE PANEL C4 SANDWICH PREP TABLE 696 23 24 <br /> CLIP. BEND OUT AS MORE THAN 56 LBS. W O <br /> WALL C5 RANGE/GRIDDLE/OVEN 10000 60 25 26 Q <br /> REQUIRED TO ENGAGE FASTEN FIXTURE TO MAIN <br /> MAIN "TEE" RUNNERS. 2 27 28 Z � <br /> 1/4" HOLE IN CLIP FOR <br /> RUNNER W/#8x1/2 HOOD LIGHT/ANSUL 500 20/1 29 30 <br /> SUSPENSION RUNNERS SELF-TAPPING TEK SCREWS, Q �u <br /> ONE AT EACH CORNER 208V, 240V SYSTEM C7 WORKTOP FREEZER 384 20 1 31 32 — > <br /> (42 FOR 480V SYSTEM) / W <br /> CEILING TILE DEDICATED, CLEAR, UNOBSTRUCTED C8 COFFEE BREWER 5060 30 33 34 1200 SIGN J Q N <br /> 36 WORKING SPACE IN FRONT OF PANEL 2 35 36 180 ROOF OUTLETS W <br /> AND FUSED DISCONNECT, FLOOR TO C9 COFFEE GRINDER 960 20/1 37 38 540 SHOW WINDOW OUTLETS Z � <br /> T—BAR LAY—IN FLUORESCENT STRUCTURAL MEMBER ABOVE PER C.E.C. W cV <br /> LIGHT FIXTURE 110-26 & ARTICLE 408. VERIFY ALL C10 TOASTER 1776 1 139140720 OUTLETS N <br /> POSSIBLE CONFLICTS WITH OTHER TRADES C11 SOUP WARMER 804 1411 1421360 OUTLETS <br /> 15" 15" PRIOR TO ROUGHING IN THE PANELBOARD. 25136 VA TOTAL 19128 <br /> Z <br /> MOUNTING DETAIL: LAY-IN FIXURE PANELBOARD CLEAR WORKING SPACE ° <br /> SCALE: N.T.S. SCALE: N.T.S. » » <br /> SIMILAR FOR FUSED DISCONNECTS PANEL HV <br /> LABELS FOR FEEDERS ORIGINATING LOCATION HALL TITLE 24 CATEGORY: EQUIPMENT o <br /> WITHIN DISTRIBUTION PANEL/ TOTAL KVA 23.7 CONNECT AMPS: 65.7 Q <br /> WOOD JOIST SWITCHBOARDS: MOUNTING FLUSH VOLTAGE 120/208V, 30, 4WLn <br /> J <br /> GYP. BOARD CEILING BUSSING 100A ❑ MCB ® MLO FEEDER ® SEE ONE LINE DIAGRAM w <br /> NAME OF PANEL/EQUIPMENT SERVED TO DIST. PANEL "DCR" A.I.C. 18000 ❑ EXISTING <br /> SURFACE LIGHT FIXTURE • FEEDER WIRE SIZE • eq' • FEEDER (2)4#500 MCM • DESCRIPTION LOAD BRKR BRKR LOAD DESCRIPTION U <br /> FASTEN FIXTURE TO WOOD 20 1 2 45 U <br /> JOIST WITH #12x2" RIFWS. <br /> (TOTAL OF 4 PER FIXTURE) RFC-1 648 3 4 9000 RTU-6 VQ <br /> LABELS AT EQUIPMENT DISCONNECTS: 3 5 6 3 LU LU OL <br /> KHF-1 1587 20/1 7 8 45 o Q <br /> EQUIPMENT FED CHILLER CH-1 MAU-1 828 20/1 9 10 9000 RTU-7 U Uj <br /> FIXTURE INSTALLED AT 90° TO JOISTS FED FROM PANEL FED FROM MOTOR CONTROL CENTER "MCCN1" 20 11 12 3 <br /> • • <br /> eq. • • REMOVE WALL FINISH & ww <br /> FEEDER WIRE SIZE FEEDER 3#3/0 EXPOSE STUDS AS RCU-1 2592 13 14 Q z <br /> VOLTS / AMPS / PHASES 480V / 150A / 30 NECESSARY TO INSTALL I I „ „ <br /> PANEL. REFINISH & (e)2 x4 WOOD STUD 3 15 16 O <br /> 17 18 <br /> „ LABELS FOR SWITCHBOARD/DISTRIBUTION PAINT TO MATCH EXIST. <br /> FASTEN WOOD BLOCKING TO 2x6 WOOD BLOCKING PANELS & BRANCH CIRCUIT PANELS: I I FLUSH ELECTRICAL PANEL 19 20 <br /> WOOD JOIST USING #16d NAILS (TOTAL OF 2 PER FIXTURE) <br /> (TOTAL OF 3 EACH END) PANEL NAME PANEL EM 21 22 <br /> FEED FROM PANEL FED FROM PANEL "DCR" I I 23 24 QROFEssioNq <br /> '~ 2"x6" WOOD JOIST FEEDER WIRE SIZE eq. FEEDER 4#4/0 STUDFASTS W/#PANEL2 1 T�/2 �� c <br /> ' • • • • WOOD SCREWS AT (6) 27 28 s ti ti <br /> GYP. BOARD CEILING VOLTS / AMPS / PHASES 208V / 200A / 3� I I �' No. Eia3o3 m <br /> FASTEN FIXTURE TO WOOD PLACES (3 EA. SIDE) 29 30 Exp. 6-30-2 <br /> BLOCKING WITH #12x2" RHWS SURFACE LIGHT FIXTURE <br /> (TOTAL OF 4 PER FIXTURE) NOTES: 31 32FBF TR <br /> c � <br /> 1. NAMEPLATES SHALL BE CONSTRUCTED OF ENGRAVED BAKELITE — BLACK BACKGROUND RELOCATE (e) STUD AS 20 33 34 9TFOF CAOTRF <br /> WITH WHITE LETTERS. NEEDED TO INSTALL I I 35 36 <br /> PANEL FLUSH IN WALL 37 38 <br /> 1 , <br /> FIXTURE INSTALLED PARALLEL TO JOIST 2. MINIMUM SIZE TO BE 1"x3". I <br /> 39 40 <br /> 3. RIVET NAMEPLATES TO ENCLOSURE. 41 r <br /> 2 DATE : FEBRUARY 2020 <br /> 0 <br /> 4. FILL—IN UNDERLINED NAMES AND VALUES FOR EACH NAMEPLATE TO INSTALLED. yu 5655 VA TOTAL 18000JOB NO. : 19-130 1 <br /> 5. ALL DISCONNECTS, PANELS, AND CIRCUIT BREAKERS INSTALLED UNDER THIS PROJECT MOUNTING DETAIL. <br /> Engineering DRAWN : BA <br /> SHALL HAVE A NAMEPLATE AS SHOWN HERE. CHECKED : RCS <br /> MOUNTING DETAIL: SURFACE FIXTURE 6. NAMEPLATES FOR EMERGENCY POWER FED EQUIPMENT SHALL HAVE RED BACKGROUND RECESSED ELECTRICAL PANEL 50 years SHEET <br /> WITH WHITE LETTERS. <br /> 4512 Feather River Dr#F,Stockton,CA 95219 <br /> SCALE: N.T.S. NOMINAL DIMENSIONS: 26"Hx20"Wx5.75"D SCALE: N.T.S. 209-478-8270 I www.hcs-eng.com <br /> NAMEPLATES / LABELS WEIGHT: 80 LBS. <br /> ® ° <br /> Richard C.Smith,PE richard@hcs-eng.com a <br /> v Bhupendra Patel,PE Bhupendra@hcs-eng.com • o <br /> E02 <br /> SCALE: N.T.S. 11 Elizabeth Aguilar elizabeth@hcs-eng.com o <br /> 0 <br /> PROJECT#2020.080 <br /> api COPYRIGHT 2019 ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.