INSTALL_2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
13975
>
2300 - Underground Storage Tank Program
>
PR0231622
>
INSTALL_2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:41 AM
Creation date
12/23/2020 9:14:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2012
RECORD_ID
PR0231622
PE
2351
FACILITY_ID
FA0000055
FACILITY_NAME
TESORO (SPEEDWAY) #68150
STREET_NUMBER
13975
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
APN
01908014
CURRENT_STATUS
01
SITE_LOCATION
13975 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
260
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. SYSTEM PIPING CONTINUED: <br /> Check Cod <br /> Box Sec on <br /> l� HSC Piping compatible with material intended to be stored. <br /> 2529902 c 1 <br /> O� 23 CCR <br /> 2631(b) Design and construction of piping approved by independent testing organization e. . UL). <br /> Piping,including vent lines,sloped toward tank(s)with minimum 1/4 inch sloe per 1 foot of run. <br /> 25290.1((k)) Vapor recovery,fill riser, and vent line piping are secondarily contained. <br /> 25290.2(c)&Q) <br /> G. OVERSPILL/ OVERFILL PREVENTION: <br /> Check Cod.9 <br /> Box 8Sac on <br /> / 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> [7 2635(b) Manufacturer 0.F Model <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> ❑Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alar <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity: and activate an <br /> d 2635(b)(2) audibi alar at least five minutes before the tank overfills <br /> Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shutoff of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer 0 ) Model G t <br /> H. CORROSION PROTECTION: <br /> Check code <br /> Box section <br /> Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> Z 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) <br /> RP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: 0 Sacrificial Anode <br /> 23 CCR ❑ Steel tank with field installed cathodic protection or impressed <br /> 2635(x)(2) current <br /> ❑ Tie-downs,when used,constructed of noncorrosive material or coated steel. <br /> Revised 8/1/11 7 <br />