My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0041310
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Z
>
ZUCKERMAN
>
2121
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0041310
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2020 2:45:44 PM
Creation date
12/23/2020 2:42:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0041310
PE
4371
STREET_NUMBER
2121
Direction
N
STREET_NAME
ZUCKERMAN
STREET_TYPE
RD
City
STOCKTON
Zip
95206-
APN
12908009
ENTERED_DATE
10/6/2020 12:00:00 AM
SITE_LOCATION
2121 N ZUCKERMAN RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\fgarciaruiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 $I 3 4 5 $I 6 7 °IS 9 10 <br /> BOTTOM OF NEXT ANODE <br /> (IF APPLICABLE) <br /> 38 33 <br /> DET 2 <br /> 60 61 <br /> 34 <br /> i <br /> E AC POWER SUPPLY NOTES: E <br /> 1.ALL COMPONENTS TO BE INSTALLED <br /> CONDUIT FROM TRANSFORMER - <br /> TO A76 WITHIN SAME QUADRANT OF POLE. - CALCINED PETROLEUM <br /> 2.HEIGHT RECOMMENDED COMPONENT CABLE(S)STRAPPED IC - COKE BREEZE <br /> 7G ,z REMOTE MONITOR UNIT HEIGHTS BARED ON FIELD CONDITIONS, VENT PIPE WITH PLASTIC <br /> QUADRANT OF AY,POSITION,ASAPEDESTRIAN CABLE TIER AT AS REQUIRED <br /> bd 69 RIGHT OF WAY,AND SAFETY. ORAS REQUIRED <br /> 49 30 32475667 3.THEMAXIMUMMU THE TOP <br /> 23 33 q NSTALL HE PG&E ARC FLASHCHEAZARD" ANODE WIRE <br /> 70 POLE DET S �� 30 4 57 STICKER ON HE FRONT DOOR OF HE CONTINUOUS TO AIB <br /> 6 3a 33 36AC DISCONNECT <br /> AC DISCONNECT .S.INSTALL THE PG&E EQUIPMENT ID STICKER I I <br /> CONCRETE WELL SEAL OR NATIVE BACKFILL ID <br /> - m � dd K6 AWG WIRE 70 ON THE FRONT DOOR OF THE RECTIFIER. tt IE IF <br /> _y AS REQUIRED BY REGULATORY AGENCY RECTIFIERGROUNDING RODS <br /> 6B 29 30 <br /> NON-PERFORATED VENT PIPE m 4 iT DET 3 PERORATED 2"VENT PIPE ANODE CENTRALIZER,(3)V LONG 1/8"x 1/4", <br /> ABOVE COKE ZONE HOT ROLLED STRIP @ 120°ATTACHED TO ANODE <br /> i o.. WITH STEEL HOSE CLAMPS ATTACHED ON BOH <br /> a Ii ENDS OF CENTRALIZERS <br /> CALCINED PETROLEUM < - <br /> d <br /> COKE BREEZE AN 'UNCTION BOX(AIB) <br /> TO BE INSTALLED AT SUITABLE p <br /> 71d 17 1fl LOCATION ON POLE <br /> STEEL HOSE CLAMPS <br /> ANODE WIRES d3 63 ATTACHED ON BOTH <br /> CONTINUOUS TO AIB 1-1/4"PVC COUDUIT <br /> FOR PIPE CABLE ENDS OF CENTRALIZERS <br /> ° 68 l0 <br /> ~ TG TG TUBULAR HIGH-SILICON <br /> ANODE CENTRALIZER <br /> o Ip CAST IRON ANODES 2.2"x 7" <br /> a d iP� 53 z3 d0 9 do vc of WITH ANODE WIRE p8 AWG) <br /> AS CADWELD(2)CATHODE WIRES IE HMWPE,HALAR(BLACK <br /> CAST IRON ANODE15 TO HE TOP QUARTER OF THE ANODE CABLE CONTINUOUS <br /> WARNING TAPE 35 11 <br /> 1d v6 (E)GAS PIPELINE FROM ANODE TO AIB <br /> � <br /> Ic iD IF DET 4 <br /> iE <br /> o � � FROM ANODE WELL <br /> I I 2v 2z 3 <br /> ANODE WIRES <br /> (EACH AN WIRE _ <br /> I I DET <br /> 1 LABELLED IN AIB) FAY—+1 <br /> _ I� 39 <br /> 18' 6'-0' (E)6"L-057A-M125 <br /> C 8 ' to I. C <br /> I< I TOP OF NEXT ANODE <br /> I I (IF APPLICABLE) <br /> I I <br /> I I DETAIL 1 PTIP ER SRO DDEEP STALL GUIDE <br /> FIGURE 6 <br /> I I <br /> I I SCALE:NTS <br /> NOTE:LABEL EACH ANODE CABLE IN HE AIB WITH A BRASS TAG. <br /> LABEL THE ANODES PEER THE ELEVATION A IDENTIFICATION. <br /> NOTE:ONLY THE FIRST ANODE IS REQUIRED TO <br /> DET <br /> BE STRAPPED TO THE VENT PIPE <br /> 6 <br /> q 1"FLEX CONDUIT <br /> q o TO RECTIFIER <br /> z TG 1O 5 n (165HUNTMAN NEMA <br /> N6 AWG POSITIVE 3 <br /> TO RECTIFIER <br /> K6 AWG <br /> B s 53 m NEGATIVE TO RECTIFIER 51 B <br /> 33 COPPER BUS BAR 3 3 <br /> So_ <br /> 5A SHUNTS 5i <br /> NUMBER TO MEET SOmv-SOA <br /> ANODES 2-13 22 WARNING TAPE NEGATIVE SHUNTSO <br /> NUMBER OF ANODES <br /> 2123 BRASSTAGS 55 <br /> 2-1/2"PVC CONDUIT 39 20 <br /> 13 iC ID iF Zd 25 1"PVC CONDUIT 2" 3" 2'• <br /> PERFORATED VENT PIPE IN 6e IE 17 18 <br /> COKE BREEZE SECTION OF HOLE k8 AWG ANODE CABLES <br /> 35 N6 AWG /L GASTRANSMISSION <br /> D <br /> IC NEGATIVE CABLE DETAIL 4 ESTIMATING&DESIGN <br /> i a IE IF <br /> ID <br /> FROM PIPE CADWELD WIRER U PIPELINE <br /> < FROM ANODES PER CCV 0-30,FIGURE 1 <br /> SCALE:NTH &TD-4181P-502 <br /> DETAIL 2 -p,,,,GDS0-13.2,FIGURE 8R DETAIL 3 PER GDS 0.13.NODE 1CIN BOX DETAIL 2,FIGURE 10 <br /> VENT PIPE CAP SCALE:NTS SCALE:NTH <br /> A A <br /> WARNING: PIPELINE-DETAILS au Of MATL SHEET? <br /> ELEVATION A TNISDOCUMENTCONTAINS L-057A-M 125 MP 0.18 <br /> EXTRA DEEP WELL ANODE SYSTEM CONFIDENTIAt,PROPRIETARC-1547 <br /> Y INSTALL 300'DEEP WELL ANODE O <br /> PER GDS 0-13.2,FIGURES INFORMATION THAT IS THE 501E ioe lD <br /> SCALE:NTS 4 PROPERTY OFPAOPCGASAND "„ <br /> ELERRICCOMPANYANDIS % STOCKTON,SAN JOAQUIN COUNTY <br /> INTENDED FORUSEONLYBY " SNEET NO 5 DF 7 SHEETS <br /> AUTHORIZEDPAUFIC GAS AND Know Wlal'e below. B 62Li0 ISSUED FOR CONSTRUCTION 1W30i9D MGV RMI GASTFANSMLSSONSDISTRIBUTION <br /> ELECTRIC COMPANY EMPLOYEES 1NxufmON PACIFIC GAS AND ELECTRIC COMPANY <br /> AND ITS AGENTS. Call before YOU dig. xD 74030790 0 <br /> C PGBE Ca. REVISIONS SAN FRANCISCO,CALIFORNIA <br /> 1 2 $I 3 4 5 $I 6 7 $I8 F.�PP:PHS 19 1 10 R Na <br />
The URL can be used to link to this page
Your browser does not support the video tag.