Laserfiche WebLink
2opClU�fy c ' SAN 10 A Q U I N Environmental Health Department <br /> COUNTY Jasjit Kang , REHS , Director <br /> "C% <br /> ' iMuniappa Naidu , REHS , Assistant Director <br /> qFoa? Greatness grows here . <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Melissa Nissim , REHS <br /> Steven Shih , REHS <br /> October 6 , 2021 <br /> TONY MEHROHE <br /> TANK TIGHT SYSTEMS INC <br /> 8515 WATERMAN RD <br /> ELK GROVE , CA 95624 <br /> Re : A&A GAS AND FOOD MART SR0084270 <br /> 1330 E YOSEMITE AVE , MANTECA , CA 95336 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Replace one dispenser <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust ( sigov . org to arrange the following inspection appointments <br /> ( a 48- hour notice is required for inspection appointments ) . <br /> a . Sensor functionality : Functionality of the monitoring system must be verified to ensure that <br /> monitoring has been restored to meet the requirements of Title 23 California Code of <br /> Regulations and the Health & Safety Code . <br /> b . Verification of the dispenser footprints contained by the under- dispenser containment sump <br /> ( UDC ) . Any potential leaks from piping and fuel filters must drain directly into UDC . <br /> c . Visual inspection of the piping within the dispenser <br /> d . Since a customer hit the dispenser near the product piping a Secondary containment test of <br /> the product piping must be performed in accordance with the manufacturers ' guidelines . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) <br /> c . Possesses a valid , current certificate of training from the manufacturer(s ) of the <br /> component(s ) being tested , repaired , or serviced <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468 -3420 F 209 464-0138 1 www . sjgov . org /ehd <br />