My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4407
>
2300 - Underground Storage Tank Program
>
PR0231761
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 9:07:10 AM
Creation date
1/8/2021 2:29:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231761
PE
2361
FACILITY_ID
FA0002347
FACILITY_NAME
ERNIES GENERAL STORE
STREET_NUMBER
4407
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710059
CURRENT_STATUS
01
SITE_LOCATION
4407 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Overfill Prevention Equipment Inspection Report <br />6. OVERFILL PREVENTION EQUIPMENT <br />DETAILS <br />Tank ID (one OPE per column) <br />87 <br />91 <br />DIESEL <br />Are both vent and tank riser piping <br />❑ Yes <br />❑ <br />Yes <br />❑ <br />Yes <br />❑ <br />Yes <br />secondarily contained? <br />❑✓ No <br />❑✓ <br />No <br />❑✓ <br />No <br />❑ <br />No <br />OPE Model <br />71 SO <br />71 SO <br />71 SO <br />What is the OPE response when activated? <br />(Check all that apply.) <br />❑✓ Shut off <br />Flow <br />❑✓ <br />Shut off <br />Flow <br />❑✓ <br />Shut off <br />Flow <br />❑ <br />Shut off <br />Flow <br />❑ Restricts <br />❑ <br />Restricts <br />❑ <br />Restricts <br />❑ <br />Restricts <br />Flow <br />Flow <br />Flow <br />Flow <br />❑ Audible <br />❑ <br />Audible <br />❑ <br />Audible <br />❑ <br />Audible <br />Alarm <br />Alarm <br />Alarm <br />Alarm <br />❑ Visual <br />❑ <br />Visual <br />❑ <br />Visual <br />❑ <br />Visual <br />Alarm <br />Alarm <br />Alarm <br />Alarm <br />Are flow restrictors installed on vent piping <br />❑ Yes* <br />❑ <br />Yes* <br />❑ <br />Yes* <br />❑ <br />Yes* <br />that may interfere with the OPE operation? <br />❑✓ No <br />❑✓ <br />No <br />❑✓ <br />No <br />❑ <br />No <br />At what level in the tank is the OPE set to <br />activate? Inches from bottom of tank <br />103 <br />100.5 <br />105.5 <br />What is the percent capacity of the tank at <br />which the OPE activates? <br />9224% <br />90% <br />93.9% <br />Is the OPE in proper operating condition to <br />❑✓ Yes <br />❑✓ <br />Yes <br />❑✓ <br />Yes <br />❑ <br />Yes <br />respond when the stored substance <br />❑ No <br />❑ <br />No <br />❑ <br />No <br />❑ <br />No <br />reaches the designated regulatory level? <br />7. SUMMARY OF TESTING RESULTS <br />OPE Inspection Results <br />❑✓ Pass <br />❑ Fail <br />❑✓ <br />❑ <br />Pass[Z] <br />Fail <br />❑ <br />Pass <br />Fail <br />❑ <br />❑ <br />Pass <br />Fail <br />8. COMMENTS <br />Describe all results marked "Fail' and each <br />proposed remedy. <br />* Mark here if: <br />❑ Flow restrictors interfere with overfill prevention and equipment <br />repairs <br />required. <br />Additional copies of this page maybe attached. <br />Attach tank chart(s), measurements, calculations, and In -Tank Setup reports) <br />Page2of2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.