My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2022 4:18:32 PM
Creation date
1/8/2021 2:33:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231952
PE
2351
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
01
SITE_LOCATION
2905 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chevron Monitoring Certification Checklist <br /> Store Number: 94275 Address: 2905 W.BENJAMIN HOLT @ 1-5 STOCKTON,CA 95207 <br /> Date:2/17/2021 Technician: Brent Bowen Company:TANKNOLOGY INC. <br /> Step Instruction T1 T2 T3 <br /> Product SUPREME REG UNLEAD DIESEL2 <br /> Tank Type <br /> (DW FRP,DW Steel,SW FRP) Fiberglass Fiberglass Fiberglass <br /> 1 Annular Riser Height(measured) <br /> Tank Diameter:(from tank chart <br /> 2 for example:118.375;117.75,111,92,etc.) 118.75 in. 118.75 in. 118.75 in. <br /> 3 For FRP tanks,1/2 circumference of the tank 186.44 in. 186.44 in. 186.44 in. <br /> (0.5 X 3.14 X tank diom.)OR(q.57 x step 2) <br /> Required annular sensor length: <br /> 4 FRP=Riser+112 Circumference=step 1+step 3 186.44 in. 186.44 in. 186.44 in. <br /> Steel=Riser+diameter=step 1+step 2 <br /> Mark&label the required sensor length on <br /> 5 sensor cord.Label should be under the cap& Yes Yes Yes <br /> serve to prevent the cord being pulled too short. <br /> Is tank annular sensor in the correct position? Yes Yes Yes <br /> 6 FRP Tanks:with the marked required length Yes Yes Yes <br /> lining up with the top of the annular riser? <br /> Steel Tanks:sensor touching bottom with slack No No No <br /> above the marked required sensor length? <br /> Are the DW pipe boots pulled back in tank sumps? <br /> 8 (YIN or N/A,note if can't be verified because N/A N/A N/A <br /> clamshell pointing down) <br /> Are tank sump sensors back in their holders and <br /> 9 in the correct position? N/A N/A N/A <br /> (YIN or N/A document with photo) <br /> Approximate gallons of product dispensed for <br /> 7 purging,etc.and returned to tank 0.00 gal 0.00 gal 0.00 gal <br /> Has the Veeder Root Battery been replaced&dated prior to failsafe? <br /> (If battery backup failed,label and leave failed battery on top of console,note in comments and advise your OM) See Comment <br /> Has Veeder Root Programming before&after testing been printed&verified? <br /> (especially tank manifolding setup-see Note 2) Yes <br /> Has Veeder Root Programming before&after been attached to the Work Order? Yes <br /> Have all sensor model numbers been verified against the Veeder Root cord label? Yes <br /> Make a note if sensor label missing or illegible,&approx.cord length for-208/-209 with missing labels <br /> Additional Comments: <br /> Tested battery before fail safe. <br /> Note 1: Certain Veeder Root Software versions will automatically revert to the default tank manifold settings anytime the programming is changed,such as when sensors are <br /> temporarily Ved out,etc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.