COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2022 4:18:32 PM
Creation date
1/8/2021 2:33:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231952
PE
2351
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
01
SITE_LOCATION
2905 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> KanJ � <br /> Jas it Director <br /> COUNTY g > REHS , <br /> cP Greatness grows here . <br /> iFoa� Muniappa Naidu , REHS , Assistant Director <br /> �< = <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> March 18 , 2021 <br /> Wayne Perry Inc <br /> 30 Main Ave Suite 5 <br /> Sacramento , Ca 95838 <br /> tbaiady (a),wpsac . com Tony Baiady <br /> Re : Chevron #94275 SR0083414 <br /> 2905 W. Benjamin Holt Drive <br /> Stockton , Ca 95207 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to replace the 87 , 91 , and diesel spill container and 87 , 91 , and diesel drop <br /> tube and shut- off valve (flapper) on the underground storage tank ( UST) system at the above noted <br /> address . The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustCc slgov . orq to arrange the following inspection appointments <br /> ( a 48- hour notice is required for inspection appointments ) . <br /> a . Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test (or <br /> equivalent) . Proper drainage must also be verified . <br /> b . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume shut <br /> off. Verification of flapper functionality . Ensure that all pertinent tank charts and <br /> calculations are available for review at the time of inspection . <br /> c . Verification that ball float (s ) , if installed , do not interfere with the installed flapper valve . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board (may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) <br /> c . Possesses a valid , current certificate of training from the manufacturer(s ) of the <br /> component(s) being tested , repaired , or serviced <br /> 5 . Individuals installing underground storage tank system components must possess or work <br /> under the direct and personal supervision of an individual physically present at the work site <br /> who possesses all of the following : <br /> a . A valid , current contractor' s license issued by the Contractors State License Board <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjgov . org/ehd <br />
The URL can be used to link to this page
Your browser does not support the video tag.