My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BOEING
>
2518
>
2200 - Hazardous Waste Program
>
PR0538472
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2021 3:37:03 PM
Creation date
1/11/2021 2:40:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0538472
PE
2228
FACILITY_ID
FA0014398
FACILITY_NAME
QUEST INDUSTRIES LLC
STREET_NUMBER
2518
Direction
E
STREET_NAME
BOEING
STREET_TYPE
WAY
City
STOCKTON
Zip
95206-3937
CURRENT_STATUS
01
SITE_LOCATION
2518 E BOEING WAY
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of hazardous waste violations that have not been <br /> addressed for QUEST INDUSTRIES LLC as of January 11, 2021. <br /> Open violations from November 04, 2020 inspection <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#505-Tank system lacks adequate secondary containment or leak detection. <br /> OBSERVATION: The facility treats paint waste in a 70 gallon heated tank.The tank did not appear to have <br /> secondary containment or leak detection equipment. <br /> REGULATION GUIDANCE: <br /> See Title 22 California Code of Regulations section 66265.193 for complete details. <br /> (b)Secondary containment systems shall be: <br /> (1)designed, installed, and operated to prevent any migration of wastes or accumulated liquid out of the system to <br /> the soil,ground water,or surface water at any time during the use of the tank system; and <br /> (2)capable of detecting and collecting releases and accumulated liquids until the collected material is removed. <br /> (c)To meet the requirements of subsection(b)of this section,secondary containment systems shall be at a <br /> minimum: <br /> (1)constructed of or lined with materials that are compatible with the waste(s)to be placed in the tank system and <br /> shall have sufficient strength and thickness to prevent failure due to pressure gradients(including static head and <br /> external hydrological forces), physical contact with the waste to which they are exposed,climatic conditions,the <br /> stress of installation, and the stress of daily operation(including stresses from nearby vehicular traffic); <br /> (2)placed on a foundation or base capable of providing support to the secondary containment system and <br /> resistance to pressure gradients above and below the system and capable of preventing failure due to settlement, <br /> compression, or uplift; <br /> (3)provided with a leak detection system that is designed and operated so that it will detect the failure of either the <br /> primary and secondary containment structure or any release of hazardous waste or accumulated liquid in the <br /> secondary containment system within 24 hours, or at the earliest practicable time if the existing detection technology <br /> or site conditions will not allow detection of a release within 24 hours; <br /> (4)sloped or otherwise designed or operated to drain and remove liquids resulting from leaks, spills, or precipitation. <br /> Spilled or leaked waste and accumulated precipitation shall be removed from the secondary containment system <br /> within 24 hours, or in as timely a manner as is possible to prevent harm to human health or the environment, if <br /> removal of the released waste or accumulated precipitation cannot be accomplished within 24 hours. <br /> Ancillary equipment shall be provided with secondary containment or be inspected daily. <br /> CORRECTIVE ACTION: Immediately take the hazardous waste tank out of service until the secondary containment <br /> and leak detection deficiencies can be corrected. Dispose of the tank contents as hazardous waste. Provide a <br /> corrective action statement and supporting documentation to the San Joaquin County Environmental Health <br /> Department(EHD)within 30 days. <br /> Page 16 of 22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.