4 87 YES <br /> 5 89 YES <br /> 6 91 YES <br /> 7 NO <br /> 8 NO <br /> +AAM- <br /> +AAE- <br /> 190200 <br /> APR 22, 2021 1:11 PM <br /> SOFTWARE REVISION LEVEL <br /> VERSION 334.01 <br /> SOFTWARE+ACM- 346334-100-B <br /> CREATED - 17.01.09.16.10 <br /> S-MODULE+ACM- 330160-104-a <br /> SYSTEM FEATURES: <br /> PERIODIC IN-TANK TESTS <br /> ANNUAL IN-TANK TESTS <br /> BIR <br /> ISD/APM <br /> +AAM- <br /> +AAE- <br /> I11100 <br /> APR 22, 2021 1:11 PM <br /> 177914 7-11 32190 <br /> 4943 S. STATE RT. 99 <br /> STOCKTON.CA. 95215 <br /> AO369068905001 <br /> PRIORITY ALARM HISTORY <br /> ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME <br /> Q 3 OTHER PUL PLLD SHUTDOWN ALARM CLEAR 4-22-21 11:42AM <br /> Q 3 OTHER PUL GROSS LINE FAIL CLEAR 4-22-21 11:42AM <br /> Q 1 OTHER RUL PLLD SHUTDOWN ALARM CLEAR 4-22-21 11:41AM <br /> Q 1 OTHER RUL GROSS LINE FAIL CLEAR 4-22-21 11:41AM <br /> Q 3 OTHER PUL PLLD SHUTDOWN ALARM ALARM 4-22-21 11:24AM <br /> Q 3 OTHER PUL GROSS LINE FAIL ALARM 4-22-21 11:24AM <br /> Q 1 OTHER RUL PLLD SHUTDOWN ALARM ALARM 4-22-21 11:15AM <br /> Q 1 OTHER RUL GROSS LINE FAIL ALARM 4-22-21 11:15AM <br /> Q 3 OTHER PUL FUEL OUT CLEAR 4-22-21 10:51AM <br /> Q 1 OTHER RUL FUEL OUT CLEAR 4-22-21 10:51AM <br /> Q 2 OTHER MUL PLLD SHUTDOWN ALARM CLEAR 4-22-21 10:17AM <br /> Q 2 OTHER MUL GROSS LINE FAIL CLEAR 4-22-21 10:17AM <br /> Q 3 OTHER PUL FUEL OUT ALARM 4-22-21 10:13AM <br /> Q 2 OTHER MUL PLLD SHUTDOWN ALARM ALARM 4-22-21 10:06AM <br /> Q 2 OTHER MUL GROSS LINE FAIL ALARM 4-22-21 10:06AM <br /> Q 1 OTHER RUL FUEL OUT ALARM 4-22-21 9:57AM <br /> Q 3 OTHER PUL PLLD SHUTDOWN ALARM CLEAR 4-22-21 9:19AM <br /> Q 2 OTHER MUL PLLD SHUTDOWN ALARM CLEAR 4-22-21 9:19AM <br /> Q 1 OTHER RUL PLLD SHUTDOWN ALARM CLEAR 4-22-21 9:19AM <br /> L 6 DISP PAN DISP PAN 11-12 SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L 5 DISP PAN DISP PAN 9-10 SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L 4 DISP PAN DISP PAN 7-8 SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L 3 DISP PAN DISP PAN 5-6 SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L 2 DISP PAN DISP PAN 3-4 SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L 8 ANNULAR 89 ANNULAR SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L 1 DISP PAN DISP PAN 1-2 SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L 7 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L10 STP SUMP 87 STP SUMP SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L15 OTHER 91 FILL SUMP SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L14 OTHER 89 FILL SUMP SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L12 STP SUMP 91 STP SUMP SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br /> L 9 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 4-22-21 9:19AM <br />