Laserfiche WebLink
SAMPLES READ =7131992 <br />SAMPLES USED =7131201 <br />LAST ERROR =7057560 <br />s 6:VFM 7-8 <br />ISD DAILY' REPORT <br />LAST SAMPLE ERROR TIME: <br />APR 25 , 20'21 3 : '? OP1°1 <br />AIR FLOW METER <br />SERIAL NUMBER61981 <br />S I Nim LA I R <br />TEMP SENSOR DATA <br />1001 E YOSEMITE <br />T6: 72.498 F <br />MANTECA.CA 95336 <br />T5: 72.524 F <br />209 825 4565 <br />T4: 71.748 F <br />s 8:ATM <br />T3: 69.388 F <br />APR 26, 2021 12:15 P1�1 <br />T2: 66.352 F <br />STM P SENSOR <br />T1: 65.828 F <br />SERIAL NUMBER 7452 <br />ATM PRESSURE -0.023 PSI <br />EVR TYPE: BALANCE <br />ORIG REF DISTANCE <br />ISD VERSION 01.05 <br />FEB 1, 2021 103.60 <br />VAPOR PROCESSOR TYPE <br />CURR REF DISTANCE <br />VEEDER-ROOT POLISHER <br />APR 25.,2021 103.64 <br />REPORT DATE: APR 26 <br />ISD VERSION 01.05 <br />OVERALL STATUS PASS <br />EVR CONTAINMENT PASS <br />EVR COLLECTION PASS <br />STAGEI 0 of 0 NOTEST <br />VAPOR PROCESSOR PASS <br />SELF TEST PASS <br />SMARTSENSOR DIAGNOSTIC <br />- - <br />ISD MONITOR UP -TIME 100° <br />- - - - - - - - - - <br />PMC DIAGNOSTIC <br />---------------- <br />APR 26. 2021 12:15 PM <br />CONTAINMENT TESTS <br />PMCVERSION : 01 .04 <br />s 1:PRESSURE SENSOR <br />VAPOR PRESSURE <br />GROSS 95% 0.1 "Wim <br />DGRD 75% -0.5 "WC <br />INCHES H20: 0.002 <br />VAPOR LEAK 9 CFH <br />VAPOR PRESSURE <br />SERIAL NUMBER 7725978 <br />VEEDER-ROOT POLISHER <br />MAX 0.2 "WC <br />MIN -2.4 ..WC <br />LOAD: 0.0% <br />EFFLUENT EMISSIONS <br />---------------- <br />s 2:VR CANISTER <br />0.00 LB/KGAL <br />COLLECTION TESTS <br />GROSS <br />VAPOR VALVE <br />DAILY THROUGHPUT <br />V/L(tt) <br />SERIAL NUMBER 9120171 <br />3106 GALS <br />VALVE POSITION: CLOSEDFP <br />OPEN CAP: CHARGED <br />VAPOR PROCESSOR MODE <br />1 : BLEND3 <br />V.'L = 0.98(249) <br />CLOSE CAP: CHARGED <br />MANUAL <br />FP 2: BLEND3 <br />AMBNT TEMP: 75.26 F <br />ViL = 0.92(246) <br />OUTLET TMP: 63.42 F <br />VAPOR VALVE POSITION <br />FP 3: BLEND'S <br />SENSOR FAULTS: <br />CURRENT : CLOSED <br />V/L = 1.09(261) <br />NONE <br />REQUESTED: CLOSED <br />FP 4: BLEND3 <br />V/L = 0.87(245) <br />TEMP: 63.42 DEG F <br />FP 5: BLEND3 <br />V,/L = 0.86(245) <br />FP 6: BLEND3 <br />s 3 : VF1°1 1-2 <br />V/L = 0.87(190) <br />FP 7: BLEND3 <br />AIR FLOW METER <br />V/L = 0.88(150) <br />SERIAL NUMBER 30019 <br />FP 8: BLEND3 <br />V/L = 0.99(272) <br />s 4:VFM 3-4 <br />---------------- <br />PROCESSOR TESTS <br />AIR FLOW METER <br />VP STATUS TEST <br />SERIAL NUMBER 67621 <br />STATUS PAS: <br />EFFLUENT EMISSIONS TEST <br />0.00 LB, KGAL PASS <br />s 5:VFM 5-6 <br />AIR FLOW METER <br />SERIAL NUMBER F <br />�1304 <br />---------------- <br />SELF TEST <br />SETUP TEST PASS <br />SENSOR OUT TEST PASS <br />