My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4405
>
2300 - Underground Storage Tank Program
>
PR0508452
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2024 1:05:38 PM
Creation date
1/19/2021 10:15:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0508452
PE
2361 - UST FACILITY
FACILITY_ID
FA0007787
FACILITY_NAME
7-ELEVEN INC #41341
STREET_NUMBER
4405
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11024013
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
4405 PACIFIC AVE STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />AMENDED <br />8/30/2021 <br />Underground Storage Tank Program Inspection Report <br />Date: <br />June 24, 2021 <br /> Facility Address: <br /> 4405 PACIFIC AVE, STOCKTON <br /> Facility Name: <br /> 7-ELEVEN INC #41341 <br />Single-Walled Non-Pressurized Piping <br /> 404 □ V □ R □ COSFailure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair (pre-1984)CCR 2643(e), 2661(f) <br />Other Violations <br /> 2010 □ V □ R □ COSUnlisted General violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 106 CCR 2632(d), 2641(h) Failure to submit and maintain a current facility plot plan / site map. <br />OBSERVATION: An accurate UST Monitoring Site Plan was not submitted. One of the site maps lists the 87 & 91 <br />tanks as 10,000 gallons each. Removed dispensers are still included on two of the site maps. <br />REGULATION GUIDANCE: A site plan must be submitted identifying the locations where monitoring will be <br />performed. The site plan must show the general layout of tanks and piping and clearly identify locations of the <br />following equipment, if installed: 1) monitoring system control panels; 2) in-tank liquid level probes (if used for leak <br />detection); 3) devices monitoring tank annular spaces or vault; 4) devices monitoring product piping; 5) devices <br />monitoring fill piping; 6) devices monitoring vent piping; 7) devices monitoring vapor recovery piping; 8) devices <br />monitoring vent/transition sumps; 9) devices monitoring under-dispenser containment; 10) line leak detectors; and <br />11) devices monitoring any other secondary containment areas. <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This is a minor violation. <br /> 109 CCR 2715(a)(1)(B), 2715(a)(3) Failure to submit "Designated Underground Storage Tank Operator Identification <br />Form" within 30 days. <br />OBSERVATION: The Designated Underground Storage Tank Operator Identification Form was not submitted in <br />CERS and was marked as Exempt. Facility is no longer in temporary closure as of 6/17/2021. <br />REGULATION GUIDANCE: By January 1, 2005, owners of underground storage tank systems shall submit a <br />signed statement to the local agency indicating that the owner understands and is in compliance with all applicable <br />underground storage tank requirements, and identifying the designated UST operator(s) for each facility owned. <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br />This is a minor violation. <br />FA0007787 PR0508452 SC001 06/24/2021 <br />EHD 23-01 Rev. 9/16/2020 Underground Storage Tank Program OIRPage 4 of 7 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.