Laserfiche WebLink
Appe- �x F-2 <br /> Is the primary tank free of water or has another preventative measure been taken? <br /> 4 NOTE`: Refer to paragraphs 6.10 and 6.11 of the standard for alternatives for Category 1 Yes ❑ No ❑ N/A <br /> tanks.N/A is only appropriate for these alternatives. <br /> 5 For double-wall or double bottom tanks orCE-ASTs, is interstitial monitoring equipment Yes ❑ NO ❑ N/A <br /> (where applicable) in good working condition? <br /> 5 For double-wall tanks or double bottom tanks or CE'-ASTs,is interstice free of liquid? Yes ❑ NO ❑ N/A <br /> Remove the liquid if it is found. If tank product is found,investigate possible leak. <br /> Equipment on tank <br /> 7 If overfill equipment has a"test'button,does it activate the audible horn or light ❑Yes ❑ No% N/A <br /> to confirm operation? If battery operated, replace battery if needed. <br /> $ Is overfill prevention equipment in good working condition?If it is equipped with a ❑Yes ❑ NO N/A <br /> mechanical test mechanism,actuate the mechanism to confirm operation. <br /> 9 Is the spill container(spill bucket)empty,free of visible leaks and in good working ❑Yes ❑ No N/A <br /> condition? <br /> 10 Are piping connections to the tank(valves,fittings,pumps,etc.)free of visible leaks? Yes ❑ No <br /> Note:If"No",identify location and describe leak. <br /> 11 Do the ladders/platforms/walkways appear to be secure with no sign of severe corrosion <br /> or damage? Yes ❑ No ❑ N/A <br /> Containment(Diking/impounding) <br /> 12 Is the containment free of excess liquid,debris,cracks,corrosion,erosion;fire hazards and ❑Yes ❑ No N/A <br /> other integrity issues? l <br /> 13 Are dike drain valves closed and in good working condition? ❑Yes ❑ No N/A <br /> 14 Are containment egress pathways clear and any gates/doors operable? ❑ Yes ❑ No N/A <br /> Concrete Exterior AST(CE-AST) <br /> 15 Inspect all sides'for cracks in concrete. Are there any cracks in the concrete exterior larger <br /> than 1/16°? ❑ Yes ❑ No N/A <br /> 16 Inspect concrete exterior body of the tank for cleanliness,need of coating,or rusting where ❑Yes ❑ No N/A <br /> applicable. Tank exterior in acceptable condition? <br /> Visual inspect all tank top openings including nipples,manways,tank top overfill containers, <br /> 17 and leak detection tubes. Is the sealant between all tank top openings and concrete intact ❑ Yes ❑ No N/A <br /> and in good condition? <br /> Other Conditions <br /> 18 is the system free of any other conditions that need to be addressed for Yes ❑ NO <br /> continued safe operation? <br /> Monthly Checklist Page 2 of 3 <br />