Laserfiche WebLink
AppF lix F-2 <br /> N the primary tank free of water or has another preventative measure been taken? <br /> 4 NOTE: Refer to paragraphs 6.10 and 6.11 of the standard for alternatives for Category 1 'Yes ❑ No ❑ N/A <br /> tanks.N/A is only appropriate for these alternatives. <br /> 6 For double-wall or double bottom tanks or CE-ASTs, is interstitial monitoring equipment ❑ Yes ii NO N/A <br /> (where applicable) in good working condition? <br /> 6 For double-wall tanks or double bottom tanks or CE-ASTs, is interstice free of liquid? <br /> Remove the liquid if it is found. If tank product is found, investigate possible leak. /Yes ❑ No ❑ N/A <br /> Equipment on tank <br /> 7 If overfill equipment has a"test'button, does it activate the audible horn or light <br /> to confirm operation? If battery operated, replace battery if needed_ t/Yes ❑ No ❑ N/A <br /> $ Is overfill prevention equipment in good working condition?If it is equipped VIM a ,a YeS ❑ NO ❑ N/A <br /> mechanical test mechanism,actuate the mechanism to confirm operation. <br /> 9 Is the spill container(spill bucket)empty, free of visible leaks and in good working <br /> condition? ➢-Yes ❑ No ❑ N/A <br /> 10 Are piping connections to the tank(valves,fittings, pumps,etc.)free of visible leaks? <br /> Note:If"No", identify location and describe leak. ❑✓Yes ❑ No <br /> 11 Do the ladders/platforms/walkways appear to be secure with no sign of severe corrosion '' <br /> or damage? ❑ Yes ❑ No ❑ N/A <br /> Containment(Diking/Impounding) <br /> 12 Is the containment free of excess liquid,debris,cracks, corrosion,erosion,fire hazards and <br /> other integrity issues? yYeS ❑ No ❑ N/A <br /> 13 Are dike drain valves closed and in good working condition? ❑ Yes ❑ No ;� N/A <br /> 14 Are containment egress pathways clear and any gates/doors operable? <br /> [;-Yes ❑ No ❑ N/A <br /> Concrete Exterior AST(CE-AST) <br /> 15 Inspect all sides for cracks in concrete. Are there any cracks in the concrete exterior larger <br /> than 1/16°? ( � ❑ Yes �JNo ❑ N/A <br /> 16 Inspect concrete exterior body of the tank for cleanliness, need of coating, or rusting where e ❑ NO ii N/A <br /> applicable. Tank exterior in acceptable condition? <br /> Visual inspect all tank top openings including nipples, manways,tank top overfill containers, 10 l <br /> 17 and leak detection tubes. Is the sealant between all tank top openings and concrete intact VYeS ❑ No ❑ N/A <br /> and in good condition? <br /> Other Conditions <br /> 18 Is the system free of any other conditions that need to be addressed for <br /> continuedsafeoperation? eS ❑ NO <br /> Monthly Checklist Page 2 of 3 <br />