Laserfiche WebLink
SERVICE NOTICE n AUTO THEFT LIMIT <br /> DISABLED <br /> DISABLED AUTO DELIVERY START <br /> DISABLED <br /> IAUTO DELIVERY END <br /> SO 3166 COUNTRY <br /> SETUP CODE: DISABLED <br /> SETUP <br /> SYSTEM AUTO EXTERNAL INPUT ON <br /> - - - - - - - - - - - -- DISABLED <br /> OCT 13. 2020 9:51 AM AUTO EXTERNAL INPUT OFF <br /> VAPOR MOgITORING TYPE DISABLED <br /> CARB ISD ; AUTO SENSOR FUEL ALARM <br /> DISABLED <br /> SYSTEM UNITS MASS,�DENOITY AUTO SENSOR WATER ALARM <br /> U.S. DISABLED ! DISABLED <br /> SYSTEM LANGUAGE AUTO SENSOR OUT ALARM <br /> ENGLISH FISCAL HEIGHT SECURITY DISABLED <br /> SYSTEM DATE.:TIME FORMAT DISABLED <br /> MON DD YY! HH:Mt°I:SS xM <br /> CHEVRON I NVENTOR� ALARMS UNITS <br /> 2751 W.KETTLEMAN LN <br /> LODI CH. 95242 CONFIG: TANDARD <br /> MAX OR LABEL: VOLUME <br /> HIGH PR06UCT: MAX <br /> SHIFT TIME 1 5:00 AM OVERFILL' : % MAX RS-232 END OF MESSAGE <br /> SHIFT TIME 2 DISABLED DELIV NEEDED: % MAX DISABLED <br /> SHIFT TIME 3 DISABLED LOW PRODPCT : VOLUME <br /> SHIFT TIME 4 DISABLED ! <br /> TANK PER TST NEEDED WRN ALARM REDUCTION <br /> DISABLED DISABLED <br /> TANK ANN TST NEEDED WRN <br /> DISABLED <br /> LINE RE-ENABLE METHOD � <br /> PASS LINE TEST <br /> LINE PER TST NEEDED WRN IN-TANK SETUP <br /> DISABLED - - - - - - - - - - _- - <br /> LINE ANN TST NEEDED WRN <br /> DISABLED T 1 :REGULAR UNLEADED <br /> PRODUCT CODE I <br /> PRINT TC VOLUMES THERMAL COEFF :.000700 <br /> ENABLED COMMUNICATIONS SETUP TANK DIAMETER 119.50 <br /> - - - - - - - - - - - - TANK PROFILE 4 PTS <br /> TEMP COMPENSATION FULL VOL 19951 <br /> VALUE (DEG F ) : 60.0 89.6 INCH VOL 16193 <br /> STICK HEIGHT OFFSET PORT SETTINGS: 59.8 I NCH VOL 10017 <br /> DISABLED 29.9 INCH VOL 3781 <br /> ULLAGE: 90% COMM BOARD i (ED I P9 ) <br /> RS-232 SECURITY <br /> H-PROTOCOL DATA FORMAT CODE : DISABLED FLOAT SIZE: 4.0 IN. <br /> HEIGHT WATER MINIMUM 0.000 <br /> PREC I S I 019 TEST DURATION COMM BOARD ? (RS-232) <br /> HOURS: 12 BAUD RATE 9600 WATER WARNING 1 .5 <br /> DAYLIGHT SAVING TIME PARITY EVEN HIGH WATER LIMIT: 2.0 <br /> DISABLED STOP BIT I STOP WATER ALARM FILTER: LOW <br /> RE-DIRECT LOCAL PRINTOUT DATA LENGTH: 7 DATA <br /> DISABLED RS-232 PECURIT`i' <br /> CODE : DISABLED MAX OR LABEL <br /> EURO PROTOCOL PREFIX VOLUME 19951 <br /> COMM BOARD 3 (RS-232) <br /> BAUD ROTE 300 HIGH PRODUCT <br /> PARITY ODD . MAX 95.0 <br /> STOP BIT 1 STOP (GALLONS) 1195:3 <br /> SYSTEM SECURITY DATA LENGTH: 7 DATA <br /> CODE : 000000 RS-232 SEC:URITY OVERFILL LIMIT <br /> CODE : 1SHBLED % MAX yD•0 <br /> MAINTENANCE HISTORY (GALLONS) 17956 <br /> DISABLEli <br /> AUTO TR NSM I T SETT I tVc;S: DELIVERY LIMIT <br /> % MAX 10.0 <br /> TANK CHART SECURITY AUTO LEAK ALARM LIMIT (GALLONS) 1995 <br /> DISABLED DISABLED <br /> AUTO HIGH WATER LIMIT LOW PRODUCT <br /> DISABLED VOLUME 1000 <br /> CUSTOM ALARMS AUTO OVERFILL LIMIT <br /> DISABLED DISABLED LEAK ALARM LIMIT: 99 <br /> AUTO LOW PRODUCT SUDDEN LOSS LIMIT: 99 <br /> —__ DISABLE <br /> TANK TILT 0.00 <br /> PROBE OFFSET 0.00 <br />