My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
3440
>
2300 - Underground Storage Tank Program
>
PR0231173
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 11:01:57 AM
Creation date
1/29/2021 11:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231173
PE
2361
FACILITY_ID
FA0006423
FACILITY_NAME
STOCKTON MOBIL 2
STREET_NUMBER
3440
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3440 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
^ " C,0 x I I II Environmental Health Department <br /> - U I I�1 <br /> —COUNTY <br /> TY <br /> `c v Greomess grows here, <br /> Underground Storage Tank Program Compliance Review Report <br /> Facility Name: Facility Phone: Date: <br /> STOCKTON MOBIL 2 510 467-7964 March 24 2021 <br /> Facility Address: CERS ID: <br /> 3440 E MAIN ST STOCKTON CA 95205 10182099 <br /> Inspection Contact: Title: Phone: <br /> Abdo Nashir Owner (510)467-7964 <br /> VIOLATIONS <br /> The following non-inspection related violations listed below from the California Health and Safety Code(HSC), California Code of <br /> Requlations(CCR)and/or the Code of Federal Requlations(CFR)were found. <br /> #317 CCR 2636(f)(2) Failure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flow <br /> OBSERVATIONS:OBSERVATION:The 91 VMI line leak detector failed to detect a leak when tested. <br /> REGULATION GUIDANCE:All line leak detectors shall be capable of detecting a 3-gallon per hour leak at 10 psi. <br /> CORRECTIVE ACTION: The service technician adjusted the leak detector, retested it, and it passed. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> OVERALL NOTES AND COMMENTS <br /> Violation 317 was issued after review of 2/9/2021 Monitoring System Certification test results. This violation was corrected on <br /> site by the technician. No additional follow up is required in response to this Underground Storage Tank Compliance Review <br /> Report. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate($152). To schedule an appointment, <br /> please call (209)468-3420. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Please submit all requested documentation to the address below, attention to: CAROL PRESTO, EH Specialist. <br /> If you have any questions, please contact CAROL PRESTO at(209)616-3061. <br /> FA0006423 PR0231173 SCO21 03/24/2021 <br /> Rev.9/16/2020 Page 1 of 1 Underground Storage Tank Program Compliance Review Report <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.