SAN JOANI Environmental Health Department <br /> COU N T Time In: <br /> Time Out: <br /> (',reot.ness grows ho, <br /> ­ <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: Gemco Ripon Truck Plaza Inc. Date: 02/23/2021 <br /> Address: 1022 E FRONTAGE RD , RIPON 95366 <br /> Requestor: JOHN BOREL WINNER JR, LIC#824489 Telephone: (650) 333-5558 <br /> Program Element: 2308- UST RETROFIT Request#: SR0080216 <br /> Inspection Type: 298- UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician: Robert Neimeyer ICC Service Tech/Installer Exp. Date: 10/11/2021 <br /> Manufacturer training: NOV,04/17/23 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site for the following inspection: <br /> 1) -Witnessed soil sampling conducted by Adam Burton of Costera Waste and Environmental San Francisco for Enthapy <br /> Analytical (formerly Curtis and Tompkins Labs) 2323 5th St, Berkeley, CA94710. <br /> Samples collected below UDCs , stockpile and piping 2 feet into the native soil labeled: <br /> Below UDCs-five samples <br /> - Disp-1 <br /> - Disp-2 <br /> - Disp-3 <br /> - Disp-4 <br /> - Disp-5 <br /> Below pipping four samples. <br /> - Pipe-1 <br /> - Pipe-2 <br /> - Pipe-3 <br /> - Pipe-4 <br /> Stock pile approximately 45 cubic yard two samples. <br /> -Stockpile-1 <br /> - Stockpile-2 <br /> No noticeable discoloration or odor observed. <br /> Discussed sampling and analytical requirements with the sampler referencing the sampling protocols approved in the permit.2) <br /> -Witnessed secondary piping soap test of product, vapor piping and penetration; one hour pneumatic pressure test at 5psi - all <br /> Passed. <br /> 3) -Verified secondary piping slope to containment sump. <br /> * Still needed refer to approval letter dated December 8, 2020. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. <br /> *This facility is not approve to operate the UST system. <br /> *Note: Submit a Service Request Amendment form with regards to change of scope of work- Sampling company, analytical <br /> Lab, and a new authorization to release form. <br /> If this information is not received the sampling conducted today 2/23/2021 will not be accepted and you will have to reschedule <br /> soil sampling with an approved Company. <br /> FA0000650 SR0080216 SC298 02/23/2021 <br /> EHD 23-01 Rev.09/16/2020 Page 1 of 2 Underground Storage Tank Program Service Request Inspection Report <br />