ELECTRICAL LEGEND: NOTE:
<br /> EMERGENCY LIGHTING SHALL BE INSTALLED IN ACCORDANCE WITH 2016 CBC SECTION 1008. ALL EXISTING LIGHTING IN THE KITCHEN TO BE REMAIN
<br /> EMERGENCY LIGHTS SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT REVISIONS
<br /> LESS THAN AN AVERAGE OF 1 FOOTCANDLE AND A MINIMUM AT ANY POINT OF 0.1 FOOTCANDLE
<br /> E 1
<br /> MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. By
<br /> 2'X4'CEILING MOUNTED
<br /> FLUORESCENT LIGHT 102'-0"
<br /> 0- 4"/6"LIGHT FIXTURE WITH 15 WATT 15'-5" 42'-6"
<br /> 27'-10"
<br /> LED LIGHT AT CEILING
<br /> 8'-3"
<br /> SINGLE POLE ON/OFF LIGHT SWITCH:
<br /> 36"
<br /> 7
<br /> E 10' HIGH GYP. ,�A„ C-7 i' /' ,' � i' /' /' ,' ,' ,' EXIIJ'
<br /> GFI SERVICE PLUG ( ) (E) 10' HIGH GYP.BOARD CEILING
<br /> GFI BOARD CEILING EX
<br /> DAY LIGHTING ,
<br /> D D ' ' CONTROL AREA
<br /> EXIT LITE �(E) / t--- i
<br /> E ' ' i� PRIMARY ZONE ' / / / / /DAY LIGHTING
<br /> F � D - GA �� /' ,' �'� /' �� i' 'i� ��� ' ,' /' i' �� CONTROL AREA ,' /' ,' /' /'E
<br /> PRIMARY ZONE
<br /> NIGHT LITE EMERGENCY LIGHTS WITH ) / / F/ / / IF /,- / F/
<br /> BATTERY PACK THAT CAN
<br /> LAST FOR MIN.90 MINUTES vv '
<br /> ILLUMINATION LIGHT
<br /> 0 EMERGENCY LIGHT (E) D /
<br /> 120v E
<br /> B
<br /> 240v or 208v 04
<br /> JUNCTION BOX ` (E 9' HI H
<br /> 0 � T-B ING
<br /> \C \
<br /> M1 (E)8' HIGH GYP. F% F '� '
<br /> (E) 10' HIGH GYP. BOARD CEILING (E) _ ,' // ' '
<br /> PHOTO DAYLIGHT CENSOR BOARD CEILING �
<br /> OC OCCUPANCY SENSOR or (E) / C \` \ --- ------ - E ' ' Q
<br /> DAYLIGHT SENSOR B \ (E) D (E) / <' ,\` ----------------- ----------_ - / ~
<br /> / EXIT 36C-7 z O
<br /> O
<br /> C i \` EXIT U
<br /> / Lu O
<br /> EMERGENC C �_7 EXIT / Of O
<br /> EXIT LIGHT & ILLUMINATION NOTES: LIGHT ; EXIT O� C-7 1Lcy) =
<br /> M
<br /> EXIT LIGHT&EMERGENCY LIGHTS: / E -' E --- ---- E E' /' ' W w
<br /> INSTALL EXIT LIGHT IN EACH EXIT DOOR WITH A 2-HOUR BACK UP BATTERY FOR / D D D\ a� ) ,' z NLID
<br /> FMERGENCYi- Z
<br /> THE THE EMERGENCY LIGHTS.HALL WAYS,AT EACH ROOM & IN THE REST ROOMS. (E) �YLIGHT ,' ��'- ��� / ,'EMERGENC (D U O
<br /> '" ( J - ,— \ LIGHTi �
<br /> EXIT ILLUMINATION LIGHT: --- --� ECIT� __ // / ,'� (n w o w
<br /> INSTALL ONE ILLUMINATION LIGHT IN EACH ROOM & IN EXIT HALL WAY FOR EXIT R S ---
<br /> ILLUMINATION WHEN ALL LIGHT POWER IS TURNED OFF. C \
<br /> uc t _____ z �I
<br /> EXIT LIGHT: q % , w O
<br /> ' ILLUMINATION LIGHT C=I / Q d Q
<br /> EXIT LIGHT TO BE WITH THE SAME CEILING LIGHTING POWER CIRCUIT BUT BEFORE `\ (E) _ E AA '
<br /> THE ON/OFF SWITCHES. ,,--- / \ -- --------------- ,' U) w
<br /> NOTE: } 04
<br /> INSTALL GFCI PROTECTION FOR ALL 120V, 15 AMP&20 AMP B (E) i co
<br /> / (E) 10' HIGH GYP. \ I I � � �A �'
<br /> RECEPTACLES IN THE KITCHEN. BOARD CEILING i /' '�
<br /> E ,
<br /> LIGHT FIXTURE SCHEDULE ( ) EXIT 36"
<br /> vv ,� �_-,� ,�
<br /> (E I C j fN \\ IF F -EMERGENCY IF --- F DAY LIGHTING
<br /> LIGHT CONTROL AREA
<br /> ID DESCRIPTION REMARK C i % - /PRIMARY ZONE Z
<br /> A CEILING LIGHT WITH LED 15 WATT 52 EACH in C
<br /> (E) 1 /' LO
<br /> B WALK-IN LIGHT 60 WATT WITH GLASS COVER 3 EACH 11 1 rn
<br /> q /' U
<br /> C 2' X 4' FLUORESCENT 2-TUB T-8 32 WATT 21 EACH � I F
<br /> C I \ /' A Z
<br /> D 1' X 4' FLUORESCENT 2-TUB LED 26 WATT 11 EACH D i (E) i \\\ OPEN CEILING E i Q
<br /> W
<br /> E TRACK LIGHT WITH LED 15 WATT PER LIGHT 48 EACH i EMER�4NC i < Lu U
<br /> F TRACK LIGHT WITH LED 15 WATT PER LIGHT 76 EACH (E) I \ �(E)zl_TYPE I Hoop-----` --- C LIG T� ' m F_
<br /> ---------------- r O
<br /> G 2' X 2' FLUORESCENT 2-TUB 20 WATT 1 EACH (E) ---- (E) (E) - i a Z
<br /> C \ (E)T TYPE II HOOD
<br /> '4 IF - F F I
<br /> - � �' ' U
<br /> (E) 10' HIGH GYP. E ' / W Cc
<br /> BOARD CEILING ILILUMINATION EMERGENCY E I /' ,' H Z Q
<br /> LIGHT LIGHT / —
<br /> vv A o a
<br /> - ~
<br /> cl)
<br /> ` \ ---' ' ' M Lu a
<br /> (E) (E) (E) (E) (E) `\ EXIT /' V
<br /> C C C C C
<br /> \A
<br /> /' /' ----- (E) HIGH \ ---------- \ \ /' /
<br /> CEILING _ \\
<br /> ' a ------- - ,--- ,,---� ,-- E /
<br /> ' 1 CEILING LIGHTING
<br /> / I �
<br /> ILLUMINATION E E ` E , �� `� E/
<br /> --,LIGHT
<br /> 1 /' /' LJ / L �' i' /' A
<br /> Y _ ' } ` / ,- }eK DAY LIGHTING
<br /> A A A A / A A 1 I-___1' A H ' ' ' CONTROL AREA
<br /> /' A +� ' ,' ' PRIMARY ZONE
<br /> �-7 / ILLUI�'IINATIO
<br /> / --- -----
<br /> -----
<br /> / A V / / -- / i -- i / LIGHT
<br /> / ----------------------------- -----------------1-----
<br /> / -
<br /> ---------------------------- -----
<br /> -------------------
<br /> / y ®A-----A-----A_-----A---17-K-----X------A�----!A \A A
<br /> L---`-----� '--1- --
<br /> ' XIT /r / 7-----��— T---7-------� 7 EMERGENCY q EMERGENCY
<br /> ' l -/ - ' ' ---- ----- ' ' /
<br /> / / \ - C=7 -f_ --�--- / -�--__ / / / ,' ' LIGHT LIGHT --
<br /> / �-
<br /> / L-- -- - ;--- - --� /
<br /> / - q
<br /> ' / ------ ---- / / / / / / /
<br /> A 11/ DAY LIGHTING i i ,' / / ' / ' (E)8' H GYP.
<br /> / / (E) 10i HIGH GYP. i / i / i' /' / /' /' BOARD CEILING
<br /> EMERGENCY ,' / / , / CONTROL AREA' i , , , , / , / �
<br /> / / BOARD CEILING / /
<br /> LIGHT � / , , /'PRIMARY ZONE , / � � ,' '
<br /> (E)8' HIGH GYP. �� - Designed by : T.W
<br /> EXIT,' /' ,' /' BOARD CEILING
<br /> / C-7 � A q
<br /> (E) ROOF SHEATHING M
<br /> (E) 2x6 ROOF JOIST ' ,'/ /' ,' ,'/ ,� ,� Date : Mar 20, 2020
<br /> ®24"O.C. TYP.
<br /> 2x BLOCKING A35 EA. SIDE
<br /> TYP.
<br /> O Scale : AS SHOWN
<br /> OUT DOOR SIGN 120V
<br /> 4-#10 SCREWS® JUNCTION BOX
<br /> BRACE TO ROOF
<br /> JOIST TYP. Z(E) x6 ROOF JOIST raven
<br /> ®24" O.C. TYP.
<br /> 3%8'x20 GA. STUDS®i6" O.C.
<br /> (PROVIDE BRIDGING®THIRD POINTS, I
<br /> 4'-0"O.C. MAX. TYP.) ilk_ 1 DIAG. BRACE 3%"x20 GA. Job
<br /> 1.25 MAX. STUDS @ 48" O.C. STAGG. 12'-4" 12'-4"
<br /> 3%%20 GA. STRONGBACK
<br /> 5'-0"O. . WHERE L
<br /> GREATER HAN 5'-0" SHEET
<br /> 27'-0" 30'-4" 6'-0" 26'-8" 23'-4"
<br /> (E)GYP.BOARD CEILING %GYP.BOARD CEILING
<br /> S.A.D. S.A.D.
<br /> 12" 4-#10 SMS TYP.
<br /> A%"x20 GA. DIAG. BRCG @ EA. CONTACT
<br /> W/2-#10 SMS®EA.
<br /> 7
<br /> CONTACT®10'-0"O.C. TYP.
<br /> 20 GA. x1Yz"x1Yz"CONT. BENT 24"
<br /> CEILING LIGHTING LAYOUT
<br /> PLATE W/2-#10 SMS®EA.
<br /> CONTACT, TYP. ALL CORNERS TY GYP. BD.
<br /> TYP.
<br /> A TYP. HANGING SOFFIT DETAIL SCALE: 3/16"=1 '-0" OF SHEETS
<br /> O