My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
730
>
1600 - Food Program
>
PR0546430
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 4:16:59 PM
Creation date
2/4/2021 2:42:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546430
PE
1635
FACILITY_ID
FA0026312
FACILITY_NAME
AMOR MIO #96813L2
STREET_NUMBER
730
Direction
S
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14723003
CURRENT_STATUS
01
SITE_LOCATION
730 S CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Specifications 1.7 Environmental Conditions <br /> An ANSUL R-102 Fire Suppression System shall be furnished. 1.7.1 The R-102 system shall be capable of operating <br /> The system shall be capable of protecting all hazard areas associ- within a temperature range of 32°F to 130°F <br /> ated with cooking equipment. (0°C to 54°CI. <br /> 1.0 GENERAL 2.0 PRODUCT <br /> 1.1 References 2.1 Manufacturer <br /> 1.1.1 Underwriters Laboratories,Inc.(UL) 2.1.1 Tyco Fire Protection Products,One Stanton <br /> 1.1.1.1 UL Standard 1254 Street, Marinette,Wisconsin 54143-2542, <br /> 1.1.1.2 UL Standard 300 <br /> Telephone(715)735-7411. <br /> 1.1.2 Underwriters Laboratories of Canada {ULC) 2.2 Components <br /> 1.1.2.1 ULC/ORD-C 1254.6 2.2.1 The basic system shall consist of an AUTOMAN <br /> regulated release assembly which includes a <br /> 1.1.3 National Fire Protection Association (NFPA) regulated release mechanism and a wet chemical <br /> 1.1.3.1 NFPA 96 storage tank housed within a single enclosure. <br /> 1.1.3.2 NFPA 17A Nozzles, blow-off caps,detectors,cartridges, <br /> 1.2 Submittals agent,fusible links,and pulley elbows shall be <br /> supplied in separate packages in the quantities <br /> 1.2.1 Submit two sets of manufacturer's data sheets needed for fire suppression system arrange- <br /> 1.2.2 Submit two sets of piping design drawings ments.Additional equipment shall include <br /> 1.3 System Description remote manual pull station, mechanical and <br /> electrical gas valves,and electrical switches for <br /> 1.3.1 The system shall be an automatic fire suppres- automatic equipment and gas line shut-off, and <br /> sion system using a wet chemical agent for building fire alarm control panel interface. <br /> cooking grease related fires. <br /> 2.2,2 Wet Chemical Agent:The extinguishing agent <br /> 1.3.2 The system shall be capable of suppressing fires shall be a specially formulated,aqueous solution <br /> in the areas associated with ventilating equip- of organic salts with a pH range between 7.7— <br /> ment including hoods,ducts, plenums,and filters 8.7,designed for flame knockdown and foam <br /> as well as auxiliary grease extraction equipment. securement of grease related fires. <br /> The system shall also be capable of suppressing <br /> fires in areas associated with cooking equipment, 2.2.3 Agent Tank:The agent tank shall be installed in <br /> such as fryers;griddles and range tops; upright, a stainless steel enclosure or wall bracket.The <br /> natural charcoal,or chain-type broilers;electric, tank shall be constructed of stainless steel.Tanks <br /> lava rock, mesquite or gas-radiant char-broilers; shall be available in two sizes; 1.5 gallon (5.7 L) <br /> and woks. and 3.0 gal (11.4 Q.The tank shall have a working <br /> pressure of 110 psi (7.6 bar),a test pressure of <br /> 1.3.3 The system shall be the pre-engineered type 330 psi (22.6 bar),and a minimum burst pressure <br /> having minimum and maximum guidelines of 660 psi (45.5 bar).The tank shall include an <br /> established by the manufacturer and listed by adaptor/tube assembly containing a burst disc <br /> Underwriters Laboratories(UL/ULC). union. <br /> 1.3.4 The system shall be installed and serviced by 2.2.4 Regulated Release Mechanism:The regulated <br /> personnel trained by the manufacturer. release mechanism shall be a spring-loaded, <br /> 1.3.5 The system shall be capable of protecting mechanical/pneumatic type capable of provid- <br /> cooking appliances by utilizing either dedicated ing the expellant gas supply to one or two agent <br /> appliance protection andlor overlapping appli- tanks depending on the capacity of the gas <br /> ante protection, cartridge used or three 3.0 gallon (11.4 L)agent <br /> storage tanks in certain applications. It shall <br /> 1.4 Quality Control contain a factory installed regulator deadset at <br /> 1.4.1 Manufacturer:The R-102 Restaurant Fire 110 psi (7.6 bar}with an external relief of approx- <br /> Suppression System shall be manufactured by a imately 180 psi (12.4 bar). <br /> company with at least forty years experience in It shall have the following actuation capabili- <br /> the design and manufacture of pre-engineered ties: automatic actuation by a fusible link detec- <br /> fire suppression systems.The manufacturer shall tion system and remote manual actuation by a <br /> be ISO 9001 registered. mechanical pull station. <br /> 1.4.2 Certificates:The wet agent shall be a specially The regulated release mechanism shall contain <br /> formulated,aqueous solution of organic salts a release assembly, regulator, expellant gas <br /> with a pH range between 7.7—8.7,designed hose, and agent storage tank housed in a stain- <br /> for flame knockdown and foam securement of less steel enclosure with cover.The enclosure <br /> grease-related fires, shall contain knock-outs for 1/2 in. conduit.The <br /> cover shall contain an opening for a visual status <br /> 1.5 Warranty,Disclaimer,and Limitations indicator. <br /> 1.5.1 The pre-engineered restaurant fire suppression It shall be compatible with mechanical gas shut- <br /> system components shall be warranted for five off devices;or,when equipped with a field or <br /> years from date of delivery against defects in factory-installed switch(es),it shall be compat- <br /> workmanship and material. ible with electric gas line or appliance shut-off <br /> 1.6 Delivery devices,or connections to a building fire alarm <br /> 1.6.1 Packaging:All system components shall be control panel. <br /> securely packaged to provide protection during <br /> shipment. <br />
The URL can be used to link to this page
Your browser does not support the video tag.