Laserfiche WebLink
�z = g ► <br /> HOW TO LOCATE THE POSITION OF THE 61SO ®Registered T.M. - Owens Corning Fiberglass <br /> AT 95%TANK CAPACITY Corporation <br /> The length of the upper tube and the placement of Measuring Stick <br /> the 61 SO valve body determine the shut-off point. <br /> Following the standard instructions for the OPW <br /> 61 SO will provide for initial shutoff at 95%. In all <br /> cases, the upper tube length must be a minimum of <br /> 6-1/2" plus the 7length of the,riser pipe. All length <br /> measurements are in inches. <br /> INSTRUCTIONS <br /> Riser Pipe <br /> 1. Find tank capacity in gallons)from tank with Face (T (g) <br /> p tY ( g ) Seal Adaptor To Tank To Tank <br /> calibration chart provided by tank manufacturer. Top (I.D.) Bottom <br /> 12,28 4 <br /> 2.) Calculate 95% of capacity. <br /> I>> (O—+3 6-1/2" <br /> 3.) Locate the 95% volume number on the tank <br /> calibration chart. <br /> 4.) Find the dipstick number(X)which corresponds <br /> to the 95%lank volume. And, find the dipstick <br /> number(Y)which corresponds to the EXAMPLE <br /> 100%volume. k = 85 : ► 1.) For an Owens-Corning Model G-3 Fiberglass® <br /> Tank Calibration Chart: <br /> 5.)Subtract the dipstick number(X)from the tank Tank Capacity- 10,000 gal., nominal.9,403 gal. <br /> diameter(Y)to find the upper tube reference NOTE: Use actual capacity only <br /> number(Z). Z 2. 95% of actual tank capacity 0.95 x <br /> (Y)-(X)_ (Z) C55/�'-CBS) �1 O ) p Y= <br /> 9403 gal. = 8933 gal. <br /> 6.) Subtract 2"from (Z)to find the upper tube depth <br /> 3.)The closest number which is less than 8933 gal. <br /> (C). (Z)-2" = C C�O'�Z)- Z = $ ►z+ Is 8910 gal. Choosing the closest number less <br /> than 95% of actual capacity ensures that the <br /> 7.) Is C less than 6-1/2"? initial shutoff will occur when the tank is no more <br /> than 95%full. <br /> Upper tube length is C plus the distance <br /> from the top of the FSA-400 Face Seal 4.)The calibration chart reading of 8910 gal. <br /> Adaptor installed on the riser pipe to the corresponds to a dipstick measurement of 82". <br /> inside, top lip of the storage (A). <br /> 5.) Dipstick number(X)= 82" <br /> Upper Tube Length = C + (A) F VZ + LZ =30Tank diameter(Y)= 92" <br /> (Y)- (X) = (Z) (92 "- 82"= 10") <br /> YES Upper tube length is 6-1/2" plus the riser (Z)= 10" <br /> pipe measurement(A). 6.) (Z) -2" = C (10"-2" =8") <br /> Upper Tube Length = 6-1/2" + (A) C = 8" <br /> NOTE: You must find the actual tank capacity 7.) Is 8" less than 6-1/2"? <br /> number that correlates to the 6-112" + (A) depth <br /> for the station records. This number may also NO Measure the distance from the top of the <br /> be used for the purposes of calibrating an Face Seal Adaptor installed on the riser pipe <br /> electronic tank level system. to the inside,top lip of the storage tank and <br /> obtain measurement(A). <br /> Upper tube length =C + (A) <br /> 54 <br />