Laserfiche WebLink
1f <br /> Installation Gu e: AdvanTek "-AX Treatet Systems l <br /> Appendix 1: Timer Settings Worksheet <br /> Typical timer settings for startup are calculated based on the following criteria: <br /> Parameter_�: Typical Value' <br /> Recirculation Ratio 4 to 1 (based on actual daily flow) <br /> Dose Frequency 72 to 300 cycles per day <br /> Cycle Time 5 to 20 minutes <br /> Recirculation Pump Rate 15 gpm - 30 gpm (AX10 - AX20) <br /> Timer "On"Time 30 seconds f (less than one minute) <br /> Timer "Off"Time Cycle Time -Timer "On" <br /> t <br /> Override Timer "On"Time Same as Timer "On" <br /> Override Timer "Off" Time 112 Timer "Off" <br /> These values are intended to help determine appropriate startup settings.As experience with a system is gained, adjust- <br /> i <br /> ments may be required, sometimes si niftcant ones. <br /> Example: Single family residence with an expected actual average daily flow of 225 gallon S2 <br /> i' <br /> Parameter, <br /> i r <br /> M Recirculation Ratio 4 x 225 gpd 900 gal <br /> w <br /> Pump Run Time 900 gal / 15 gpm 160 min <br /> Timer "On" 60 min / 144 cycles 25 sec <br /> Timer "Off" 10 min 1 25 sec J9 min: 35 sec <br /> Override Timer "On" Same as Timer "On" 25 sec <br /> Override Timer "Off" 9 min: 35 sec 1 2 5 min <br /> 2 Typical actual hater usage is 50 to 60 gallons per person per dau <br /> Note: Default setting will be 25 sec `ion," 9 min: 35 sec "off" <br /> ©2001 Orence Systems' Inc. EIM-ATX-AX-1 <br /> Information subject to change without notice Rev 1.48/01 <br />