INSTALLATION INSTRUCTIONS for <br /> HEALY SYSTEMS, INC. <br /> CLEAN AIR SEPARATOR <br /> The Model 9961 or 9961 H, Healy Systems Clean Air Separator(CAS)consists of a 400 gallon steel vapor <br /> processor vessel that contains a fuel resistant bladder to hold excess gasoline vapors that may develop in <br /> gasoline storage tanks during idle periods of gasoline dispensing facility operation. Models and Drawings <br /> with a "H" suffix apply to horizontal CAS installations and those without a "H" suffix apply to vertical CAS <br /> installations. The CAS assembly weighs approximately 800 pounds which makes it necessary to have a <br /> power assisted lifting device available at the installation site to remove the CAS from the transportation <br /> vehicle and place it on the required concrete pad (see drawing 9900-9945 or 9900-9945H). The pad <br /> (level within 1/8"/foot) is located within 100 feet to the gasoline storage tank vent lines. The pad is a <br /> requirement of this installation. DO NOT PLACE THE CLEAN AIR SEPARATOR DIRECTLY ON THE <br /> GROUND ORASPHALT SURFACE. NOTICE: The installer is responsible to ensure that the installation <br /> meets the latest edition requirements of NFPA 30A, Chapter 10. No electrical connections are required. <br /> The CAS securement method shown in drawing 9900-9945 or 9900-9945H shall be approved by the <br /> local authority having jurisdiction with respect to wind and seismic loading. Installer shall not loosen, <br /> rotate or remove factory installed fittings or flange as this may damage factory seals and void warranty. <br /> In addition to the vapor processor vessel, there is a hardware kit that contains the following: <br /> 4 Locking 1" NPT Ball Valves <br /> 4 Pad locks (keyed alike) <br /> 1 Breather Assembly, Healy Model 9948 <br /> 1 Float Check Valve Assembly, Model 9466G <br /> Reference the appropriate Healy Systems installation drawing (9900-9942, 9900-9942H, 9900-9971, <br /> 9900-9971 H, 9900-9972, 9900-9972H, 9900-9973 or 9900-9973H of this manual) for placement of the <br /> above parts for the vent stack configuration required by the local Authority Having Jurisdiction (AHJ) <br /> for the Underground Storage Tank (UST) system. A flexible connection between the Clean Air <br /> Separator and the vent line(s) is allowable if required by the local Authority Having Jurisdiction <br /> (AHJ) to meet seismic requirements. Should the flex connection be installed such that it is not <br /> supported, the slope of the flex connection shall be greater than the 1/8"/foot slope required for <br /> the rest of the one inch galvanized piping. The local contractor is responsible to provide all necessary, <br /> galvanized piping, non-hardening, UL classified pipe joint compound and plumbing fittings. Additional <br /> Pressure/Vacuum (P/V) vent valves to complete installation are not included in the hardware kit. Healy <br /> is not responsible for the warranty of any other P/V vent valve purchased to complete installation. <br /> The CAS arrives at the site assembled and tested. All plumbing shall be done using 1" galvanized <br /> steel pipe (Schedule 40) and approved nipples, as called out in the installation drawing appropriate for <br /> the site installation. Mounting hardware shall be galvanized or stainless steel. Careful attention must <br /> be paid to the installation drawing appropriate for the site installation to assure proper operation of the <br /> bladder system. Do not inflate the bladder assembly after installation. <br /> It is important that the CAS be secured to the concrete pad as shown in drawing 9900-9945 or <br /> 9900-9945H of this manual to prevent any unintentional repositioning of the CAS as the connecting <br /> plumbing to the vent system is accomplished. <br /> 3-1 <br /> CARR Approved IDM 3-Healy Clean Alp Separator Model 09GI and 9001H-Executive Orders VR-201 and VR-202 <br />