CalRecycle <br /> Compostable Materials Handling Operation and Facility Inspection Report (93) <br /> EnforcenentAgency:' ' '' County of San Joaquin <br /> §WIS Facility File�Niimber(99-m-9999) '. Inspection'Date _„ progeain Code 's <br /> 39-AA-0051 1/11/2011 LEA Focused <br /> Time In 12:30 pm Time Out 2:00 pm Inspection Time , <br /> Facility,dame �! H „ Received <br /> Valley Organics, Inc. Valley Organics, inc. <br /> Facility Location Owner Name. <br /> 920 West Frewert Road, Lathrop <br /> 95330 <br /> Inspector .,_ Also Present(Name) <br /> Benjamin Escotto 71Jed Phelps <br /> THE ABOVE FACILITY WAS INSPECTED FOR COMPLIANCE WITH APPLICABLE SECTIONS OF THE DIVISION 30 OF THE PUBLIC RESOURCES CODE(PRC)AND TITLE 14 AND TITLE 27 CALIFORNIA CODE OF REGULATIONS(CCR) <br /> No Violations or Areas of Concern <br /> V; A Regulations <br /> x 17869(b)-Special Occurrences <br /> Comments: The Special Occurences log was not filled out during the time of inspection (incident occured the day <br /> before). <br /> 1. The operator shall record any special occurences encountered during operation and methods used to <br /> resolve problems arising from these events. <br /> 2. The Special Occurences log must be filled out the same day as the incident occcured. <br /> 3. Complete the Special Occurences log and submit a copy to the Environmental Health Department(EHD). <br /> Inspection Report Comments: <br /> A compost inspection was performed on this date and the following was noted: <br /> 1. The feedstock caught on fire on 1/10/11 at approximately 6:30 am. According to the operator, Jed <br /> Phelps, the fire department was contacted, arrived on site, and stayed until 9:00 pm. <br /> 2. During the inspection the feedstock pile(still slightly smoldering)was being moved and separated <br /> into individual piles in order to lower the temperature. <br /> 3. The temperature range of the smoldering feedstock pile was 170 F- 184 F. <br /> 4. Records showing the daily temperatures of the feedstock were analyzed. The temperature range was <br /> 112 F-124 F. <br /> 5. It is recommended, in order to prevent future fires,that the feedstock pile is kept to a smaller <br /> volume by maintaing multiple piles. It is also recommended that multiple temperatures at varying <br /> heights be taken for the feedstock pile(s). Further incidents of fire may lead to these <br /> recommendations becoming requirements. Further incidents of fire may also lead to other <br /> requirements by the EHD. <br />