Laserfiche WebLink
ricca!idesign <br /> sluolos <br /> Submittal Sheet 02/20/2019 <br /> ITEM#A88-EXHAUST HOOD W/MAKE UP AIR(1 EA REQ'D) <br /> Streivor SAWCBD 1566024 <br /> Filter type exhaust hood with make-up air, length and width as shown on plans. <br /> ACCESSORIES <br /> Mfr Qty Model Spec <br /> Fabricated 1 Construction to consist of 18 Gauge type 304 <br /> stainless steel, including any exposed <br /> back.>External welded construction in <br /> accordance with the latest edition of NFPA 96. All <br /> welds to be ground and polished.>U.L. <br /> Classified, removable, stainless steel non <br /> adjustable grease filters. <br /> Fabricated 1 Stainless steel, removable grease can(s).>Sloped <br /> grease trough, full length below filters to grease <br /> can(s).>Hangers, supports and miscellaneous <br /> accessories as required for installation.>Air <br /> space at wall(s) to accommodate requirements <br /> of the latest edition of NFPA 96 clearance to <br /> combustibles.>AII welded duct collar(s).>Pre <br /> piping for hood fire suppression system.>Final <br /> connections to hood duct collar(s) by the <br /> Mechanical Division.>Hood construction and <br /> components to be UL and NSF listed.>Mounting <br /> height of bottom edge of hood to be 6'-8" above <br /> finished floor.>Verify and coordinate all <br /> dimensions, and duct requirements and <br /> locations with site conditions and Mechanical <br /> Division.>See ventilation drawing sheet for <br /> general size and location of duct(s).>If not <br /> installed against the finished ceiling, provide <br /> matching stainless steel closure panels above <br /> hood to finished ceiling, to conceal duct(s) and <br /> hood fire suppression system piping; verify <br /> height. If finished ceiling is more than 24" above <br /> the top of the hood(s), or ceiling is open type <br /> ceiling, verify requirement for closure panels <br /> with Architect/Interior Designer. <br /> Streivor 1 +FLUORESCENT-EH One (1) LED light fixture. Provide extra low <br /> temperature LED light fixtures with heavy duty <br /> tubes for field installation by the Electrical <br /> Division. All light fixtures to be U.L. listed for use <br /> inside walk-in cooler or freezer. All conduit and <br /> wiring between light fixtures to be concealed <br /> where possible. Refer to foodservice walk in <br /> electrical plan for number and location of light <br /> fixtures. Provide lighting inside walk-in to meet <br /> or exceed 10 foot candles as measured at 12" <br /> above finish floor. <br /> Streivor 16 EX-HOOD3-XL Budget Price Per Foot. <br /> Streivor 1 EX-HOOD3-XL Budget Price Per Half Foot. <br /> Streivor 1 CONFIRMED-XL Confirmed Budget Price from Manufacturer. <br />