My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0083281_SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
POCK
>
3657
>
2600 - Land Use Program
>
SR0083281_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2021 9:54:40 AM
Creation date
3/3/2021 9:44:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0083281
PE
2602
STREET_NUMBER
3657
Direction
S
STREET_NAME
POCK
STREET_TYPE
LN
City
STOCKTON
Zip
95205
APN
17914004
ENTERED_DATE
2/16/2021 12:00:00 AM
SITE_LOCATION
3657 S POCK LN
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. A deep percolation test hole has a depth between 3.5 and <br /> 25 feet; a satisfactory percolation rate for a deep test is greater than or equal to 1 min/in <br /> but less than or equal to 30 min/in drop. For the Site to utilize a standard septic system, <br /> one percolation test hole (shallow or deep) must demonstrate a satisfactory percolation <br /> rate within the proposed septic system disposal field. <br /> Details and results of the percolation testing are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1-S, <br /> 2/9/2021 3.42 31.25 4 hr. Satisfactory perc. <br /> Shallow Test rate <br /> P1-D, <br /> 2/9/2021 9.72 7.58 4 hr. Satisfactory perc. <br /> Deep Test rate <br /> Note: A satisfactory percolation rate for a "shallow"test is greater than 1 but less than or equal to 60 minutes per <br /> inch. A satisfactory percolation rate for a "deep" test is greater than 1 but less than or equal to 30 minutes <br /> per inch. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of a standard septic system in accordance with <br /> the requirements of the San Joaquin County Environmental Health Department. This <br /> percolation test is considered representative of soils within a 100-foot radius of the test <br /> location. <br /> Discussion of Septic System Sizing <br /> Septic system construction utilizing leach lines with seepage pits should follow the San <br /> Joaquin County On-Site Wastewater Treatment Systems Standards (2017) where <br /> applicable. <br /> LOGE 2104 Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.