My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COQQJWA84
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
795
>
2200 - Hazardous Waste Program
>
COQQJWA84
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2021 1:48:05 PM
Creation date
3/3/2021 1:41:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
RECORD_ID
COQQJWA84
PE
2220
STREET_NUMBER
795
STREET_NAME
ROTH
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19338002
ENTERED_DATE
9/24/2020 12:00:00 AM
SITE_LOCATION
795 E ROTH RD
RECEIVED_DATE
9/24/2020 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\ymoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> C I, J 'vJ I Y <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SMART TECH DIESEL REPAIR 795 E ROTH RD, FRENCH CAMP October 15, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 502 CCR 66265.192(a) Failed to comply with new hazardous waste tank system assessment requirements. <br /> OBSERVATION: This facility has a 300 gallon used oil hazardous waste tank but has not had a hazardous waste <br /> tank assessment done. <br /> REGULATION GUIDANCE: <br /> Title 22 California Code of Regulations section 66265.192(a) <br /> Owners or operators of new tank systems or components shall ensure that the foundation,structural support, <br /> seams,connections, and pressure controls(if applicable)are adequately designed and that the tank system has <br /> sufficient structural strength,compatibility with the waste(s)to be transferred,stored or treated,and corrosion <br /> protection so that it will not collapse,rupture,or fail.The owner or operator shall obtain a written assessment <br /> reviewed and certified by an independent,qualified, professional engineer, registered in California in accordance <br /> with section 66270.11(d)attesting that the system has sufficient structural integrity, is acceptable for the <br /> transferring, storing and treating of hazardous waste,and that the tanks and containment system are suitably <br /> designed to achieve the requirements of this article.This assessment shall be obtained prior to placing the tank <br /> system in service,and shall be kept on file at the facility.This assessment shall also include,at a minimum,the <br /> following information: <br /> (1)design standard(s)according to which the tank(s)and ancillary equipment are or will be constructed; <br /> (2)hazardous characteristics of the waste(s)to be handled; <br /> (3)for new tank systems or components in which the external shell of a metal tank or any external metal component <br /> of the tank system is or will be in contact with the soil or with water, a determination by a corrosion expert of: <br /> (A)factors affecting the potential for corrosion, including but not limited to: <br /> 1.soil moisture content; <br /> 2.soil pH; <br /> 3.soil sulfides level; <br /> 4.soil resistivity; <br /> 5.structure to soil potential; <br /> 6. influence of nearby underground metal structures(e.g., piping); <br /> 7.stray electric current;and, <br /> 8.existing corrosion-protection measures(e.g.,coating,cathodic protection),and <br /> (B)the type and degree of external corrosion protection that are needed to ensure the integrity of the tank system <br /> during the use of the tank system or component,consisting of one or more of the following: <br /> 1.corrosion-resistant materials of construction such as special alloys or fiberglass-reinforced plastic; <br /> 2.corrosion-resistant coating(such as epoxy or fiberglass)with cathodic protection(e.g., impressed current or <br /> sacrificial anodes);and <br /> 3.electrical isolation devices such as insulating joints and flanges; <br /> (4)for underground tank system components that are likely to be affected by vehicular traffic,a determination of <br /> design or operational measures that will protect the tank system against potential damage;and <br /> (5)design considerations to ensure that: <br /> (A)tank foundations will maintain the load of a full tank; <br /> (B)tank systems will be anchored to prevent flotation or dislodgement where the tank system is placed in a <br /> saturated zone,or is located within a seismic fault zone;and <br /> (C)tank systems will withstand the effects of frost heave. <br /> Title 22 California Code of Regulations section 66270.11 <br /> (d)Certification. I certify under penalty of law that this document and all attachments were prepared under my <br /> direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and <br /> evaluate the information submitted. Based on my inquiry of the person or persons who manage the system,or those <br /> FA0016092 PR0546244 SCO01 10/15/2020 <br /> EHD 22-02 Rev.9/16/2020 Page 12 of 18 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.