PE
2631
FACILITY_NAME
PA-2000205
STREET_NUMBER
21399
Direction
S
STREET_NAME
CARROLTON
STREET_TYPE
RD
City
RIPON
Zip
95366-
APN
24522002
ENTERED_DATE
12/1/2020 12:00:00 AM
SITE_LOCATION
21399 S CARROLTON RD
RECEIVED_DATE
10/21/2022 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f . LIGHTING : Lighting shall be provided and comply with the following : <br /> 1 . If the parking area is to be used at night , parking lot lighting shall be installed . ( Development <br /> Title Section 9 - 1015 . 5 [g ] ) <br /> 2 . Any lighting shall be designed to confine direct rays to the premises . No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares , provided , however , that <br /> such light shall not cause a hazard to motorists . ( Development Title Section 9 - 1015 . 5 [g ] [4] ) <br /> g . SIGNS : Sign details shall be consistent with Chapter 9 - 1710 of the Development Title and be included <br /> on the Site Plan . All portions of any sign shall be set back a minimum of 5 feet from any future right- <br /> of-way line , including any corner cut- off ( snipe ) . ( Development Title Section 9 - 1710 . 2 [g ] ) <br /> h . CULTURAL RESOURCES : If , in the course of development , human remains are encountered , all <br /> work shall halt in the vicinity and the County Coroner shall be notified immediately . At the same <br /> time , a qualified archaeologist shall be contacted to evaluate the finds . If Human burials are found <br /> to be of Native American origin , steps shall be taken pursuant to Section 15064 . 5 ( e ) of Guidelines <br /> for California Environmental Quality Act . <br /> i . BUILDING DEPARTMENT REQUIREMENTS : The following California Building Code ( CBC ) and <br /> San Joaquin County Ordinance requirements will be applicable to the proposed project . The <br /> following conditions shall be addressed prior to the submittal of a building permit application to the <br /> Building Inspection Division : <br /> 1 . A building permit for each separate structure or building is required . Submit plans , <br /> specifications and supporting calculations , prepared by a Registered Design Professional <br /> ( architect or engineer) for each structure or building , showing compliance with the 2019 <br /> California Building , Existing Building , Mechanical , Plumbing , Electrical , Energy and Fire Codes <br /> as may be applicable . Plans for the different buildings or structures may be combined into a <br /> single set of construction documents . <br /> 2 . A grading permit will be required for this project . Submit plans and grading calculations , <br /> including a statement of the estimated quantities of excavation and fill , prepared by a <br /> Registered Design Professional . The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code . The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code . <br /> 3 . The required plans must be complete at the time of submittal for a building permit . Plans must <br /> address building design and construction , fire and life safety requirements , accessibility and <br /> show compliance with the current California codes and San Joaquin County ordinances . A <br /> complete set of plans must include fire sprinkler plans , truss design submittals , metal building <br /> shop drawings , structural plans and calculations , plumbing , electrical and mechanical drawings <br /> and energy report . <br /> 4 . A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br /> for grading . All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings . <br /> 5 . For each proposed new building , provide the following information on the plans : <br /> A . Description of proposed use ; <br /> Be Existing and proposed occupancy Groups ; <br /> C . Type of construction ; <br /> D . Fire sprinklers ( Yes or No ) ; <br /> PA- 2000205 — Conditions of Approval 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.