Laserfiche WebLink
h . Proposed floor area <br /> i . Occupant load based on the CBC <br /> j . Occupant load based on the CPC <br /> 6 . The change in use of the existing 6 , 000 sf private agricultural building , constructed under BP - <br /> 1601817 (AG BUILDING NO UTILITIES ) referenced in the project description , will constitute a <br /> change of occupancy . A complete set of plans including the electrical , plumbing , and mechanical <br /> and code analysis report prepared by an architect or engineer in accordance with the California <br /> Existing Building Code is required . The report and plans shall identify existing conditions , propose <br /> alterations necessary to bring the building in compliance with the current code and include the <br /> following : <br /> a . Description of proposed use <br /> b . Existing and proposed Occupancy Groups <br /> c . Type of construction <br /> d . Sprinklers ( Yes or No ) <br /> e . Number of stories <br /> f . Building height <br /> g . Allowable floor area <br /> h . Proposed floor area <br /> i . Occupant load based on the CBC for the new use <br /> j . Occupant load based on the CPC for the new use <br /> k . Risk Category analysis . (Agricultural Buildings are allowed to be constructed to Risk <br /> Category I , whereas other occupancies require Risk Category II or III . ) <br /> Modifications to existing buildings are required to include upgrades related to disability access <br /> pursuant to the California Existing Building Code . Plans showing these upgrades must be prepared <br /> by a registered engineer or licensed architect and shall be submitted for review and approval prior to <br /> issuance of a building permit . <br /> 7 . If high piled combustible storage is to be used in a building , an automatic fire sprinkler <br /> system will be required . <br /> 8 . Accessible routes shall be provided per CBC § 11 13 - 206 . At least one accessible <br /> route shall be provided within the site from accessible parking spaces and accessible <br /> passenger loading zones ; public streets and sidewalks ; and public transportation stops to the <br /> accessible building or facility entrance they serve . Where more than one route is provided , all routes <br /> must be accessible . § 11 B . 206 . 2 . 1 <br /> 9 . At least one accessible route shall connect accessible buildings , accessible facilities , accessible <br /> elements and accessible spaces that are on the same site . § 11 13 -206 . 2 . 2 <br /> 10 . At least one accessible route shall connect accessible building or facility entrances with all accessible <br /> spaces and elements within the building or facility , including mezzanines , which are otherwise <br /> connected by a circulation path . § 11 13 - 206 . 2 . 4 <br /> 11 . Parking spaces will be required to accommodate persons with disabilities in compliance with Chapter <br /> 11 B of the California Building Code . Note that accessible parking spaces are required for each phase <br /> of the project . These parking space ( s ) shall be located as close as possible to the primary entrance to <br /> the building . <br /> 12 . Adequate sanitary facilities shall be provided for the facility , per the requirements of Chapter 4 of the <br /> California Plumbing Code . <br /> 1810 E . Hazelton Avenue Stockton , California 95205 ( 209 ) 46M121 www , sjgov . org / coinmdev <br />