Laserfiche WebLink
KITCHEN HOOD EXHAUST IS AT LEAST 10' AWAY FROM ANY OUTDOOR AIR INTAKE,OPERABLE OPENING, AND ADJACENT BUILDING OR PROPERTY LINE.1RTU900 cfm OA7.5-Tons32541EF8761MAU876MECHANICAL ROOFTOP PLANSCALE: 1/4" = 1'-0"10'16' - 10"9A11/21/19AAPC Comments--------------------------------A. AmadioHT11/25/2019AS NOTED22471REVISIONSNo.RemarksDRAWN:CHECKED:DATE:SCALE:JOB NO:DateSTAMP:SHEET TITLEToll Free: 800-498-4110 <br />Ceres, CA 209-538-2879 <br />LIVING & ENERGY <br />CALIFORNIA <br />A Division of William Lilly & Associates, Inc. <br />Title 24 Compliance - Residential/Non Residential <br />CONSERVATION FOR THE CALIFORNIA LIFESTYLE <br />Fax: 209-538-2885 <br />www.califliving.comDrnSHEETREVISIONSNo.RemarksDRAWN:CHECKED:DATE:SCALE:JOB NO:DateSTAMP:SHEET TITLEToll Free: 800-498-4110 <br />Ceres, CA 209-538-2879 <br />LIVING & ENERGY <br />CALIFORNIA <br />A Division of William Lilly & Associates, Inc. <br />Title 24 Compliance - Residential/Non Residential <br />CONSERVATION FOR THE CALIFORNIA LIFESTYLE <br />Fax: 209-538-2885 <br />www.califliving.comDrnSHEETFausto & Lynn Echeverria <br />(415) 404-5194 <br />Ruby Bakery & Cafe <br />11 S. Church St, Lodi CA 95240 ALL KEYNOTES MAY NOT BE APPLICABLE1.EXHAUST DUCT VENT THRU WALL (REFER TOSHEET M0.1 DETAIL 1).2.REFER TO PLUMBING PLANS FOR GAS LINE SIZESAND ROUTING.3.REFER TO PLUMBING PLANS FOR CONDENSATEDRAIN ROUTING. OTHERWISE, INSTALL PER CPCSECTION 814.0 & CMC SECTION 309.0.4.REFER TO ELECTRICAL PLANS FOR ELECTRICALFEEDS, AND MANUFACTURERS INSTRUCTIONS FORELECTRICAL CONNECTIONS AND CONTROLS.5.REFER TO STRUCTURAL PLANS FOR STRUCTURALFRAMING AND ATTACHMENTS TO STRUCTURE, ANDMANUFACTURERS INSTRUCTIONS FOR PROPERINSTALLATION.6.REFER TO HOOD, EXHAUST FAN, AND MAKE-UP AIRUNIT MANUFACTURERS INSTRUCTIONS FORPROPER INSTALLATION AND CONTROLS.7.INTERLOCK THE KITCHEN EXHAUST HOOD WITHTHE MAKE-UP AIR FAN.8.EXHAUST DUCT VENT THRU ROOF (REFER TOSHEET M0.1 DETAIL 5).9.KITCHEN HOOD EXHAUST DUCT ACCESS FORCLEANING AND INSPECTION WILL BE FROM THEROOFTOP WITH THE FAN IN THE OPEN POSITION(SEE SHEET M0.3 "FAN IN THE OPEN POSITION").THERE IS NO DAMPER IN THE EXHAUST DUCT.KEYNOTES#A.TERMINATION OF ENVIRONMENTAL AIR DUCT:·VENT/EXHAUST DUCT SHALL TERMINATE NOTLESS THAN 3 FEET FROM A PROPERTY LINEAND 3 FEET FROM OPENINGS INTO THEBUILDING (2016 CMC SECTION 502.2.1).·VENT/EXHAUST DUCT TO ROOF CAP SHALL BEROUTED PER 2016 RESIDENTIAL COMPLIANCEMANUAL SECTION 110.10 & 2016 CMC SECTION502.2.1·TYPE I HOOD TERMINATES ABOVE THE ROOF,AT A MINIMUM OF 10 FEET FROM ADJACENTBUILDINGS, PROPERTY LINES, AIR INTAKES, OROTHER OPENINGS INTO THE BUILDING; AND AMINIMUM OF 5 FEET FROM COMBUSTIBLECONSTRUCTION.B.ALL EXPOSED DUCTWORK WITHIN THECONDITIONED SPACE SHALL BE UNINSULATEDSPIRAL SHEET METAL.C.REFER TO PLUMBING PLANS FOR RTUCONDENSATE DRAIN ROUTING. OTHERWISE,INSTALL PER CPC SECTION 814.0 & CMC SECTION309.0.SHEET NOTESM-1.1MECHANICALROOFTOPPLANRTU-11060947685 / 10411.012.780%CAP. (MBH)AHRI DATAAHRI CERTIFIEDREFERENCE NUMBEREERIEERAFUECOOLING / HEATINGMARKNO.1. ALL SUPPLY & RETURN TRUNK LINES IN AN UNCONDITIONED SPACE SHALL BE R6 INSULATED SHEET METAL.2. ALL SUPPLY & RETURN BRANCH DUCTS IN AN UNCONDITIONED SPACE SHALL BE R6 INSULATED FLEX DUCT.3. ALL DUCT DIMENSIONS ARE INTERNAL DIMENSIONS.*OUTDOOR AIR CALCULATIONS** SQUARE FOOTAGE BASED ON NET OCCUPIABLE SQ FOOTAGEHVAC ROOFTOP EQUIPMENT SCHEDULETAGNo.MANUFACTURER&MODELTONFANSELECTION2nd STAGE -COOLINGCAPACITYHEATINGCAPACITYPOWEREXHAUST(HP)OUTSIDEAIR25%(CFM)ELECTRICALCONTROLSWEIGHT(LBS.)REMARKSCFMESPDRIVEKITTOTAL /SENSMBHEWB/AMBINPUT BTU/HROUTPUT BTU/HRMCAMOCPVOLT / PHAFUEFLA*RTU-17.536001.085.4 / 75.2--80%130,000104,000--9004250208 / 3PROGRAMMABLETHERMOSTAT1069 LENNOX KGB092S4B**Y,G,J2 HP, KIT 225% OA, ECONOMIZER,& BAROMETRIC RELIEF83.1*CONTRACTOR TO PROVIDE AND INSTALL AMERICAN LENNOX CURB PER MANUFACTURERS INSTRUCTIONS AND LOCAL CODE REQUIREMENTS, ECONOMIZER KIT, OUTDOOR AIR KIT, BAROMETRIC RELIEF, AND STANDARD THROW-AWAY FILTER KIT.AAAAA