Laserfiche WebLink
4"C-4#500 MCM <br /> LABELS FOR FEEDERS ORIGINATING RISER AND WEATHER HEAD PANEL C <br /> _ <br /> WITHIN DISTRIBUTION PANEL/ MAIN SERVICE SWITCHBOARD "MS": NEMA 3R LOCATION KITCHEN TITLE 24 CATEGORY: EQUIPMENT <br /> _ <br /> SWITCHBOARDS: TOTAL KVA : 31 .1 CONNECT AMPS: 129A/84A E) <br /> AA 400A – 120/24OV, 30, 4W BUS, 42000 AIC MOUNTING FLUSH VOLTAGE 120/240V 10 3W <br /> NAME OF PANEL/EQUIPMENT SERVED TO PANEL "LL" I 400/3 I BUSSING 225A ❑ MCB ® MLO FEEDER ® SEE ONE LINE DIAGRAM APEX <br /> • FEEDER WIRE SIZE • eq. • FEEDER 4#2 • I I M I I AIC 22,000 AIC ❑ EXISTING ARCHITECTURE <br /> 20� 22� 15� S� DESCFRAZILRCEION 10AD 400 20/R* 1 2 20/R1* 70AD 20 ICEMAKER845 S. Commerce Street <br /> LABELS AT EQUIPMENT DISCONNECTS: 41 C C <br /> MICROWAVE 1500 C* 3 4 596 AIR CURTAIN Stockton, CA. 95206 <br /> F REAL MILK SHAKE 780 * 5 6 1 596 AIR CURTAIN (209) 662-4874 <br /> EQUIPMENT FED 10RHP-2" SEE GROUNDING <br /> HOT FOOD 3360 40/1 7 1 g * 756 SANDWICH PREP apexplanning@hotmail.com <br /> FED FROM PANEL e4 PANEL "LH" DETAIL "F/E6", M M OIL FITTER 744 20/1 9 10 * 1400 OVEN <br /> • FEEDER WIRE SIZE • • FEEDER 3#8 • THIS SHEET. SODA 840 * 11 12 * 1400 ICEE Steven Anthony Torres II <br /> VOLTS / AMPS / PHASES 208V / 70A / 30 = ICE CREAM FREEZER 840 * 13 14 * 1200 REFRIGERATOR Architect # C32553 <br /> DISPLAY ICE 1200 * 15 16 200 ATM <br /> LABELS FOR SWITCHBOARD/DISTRIBUTION FREEZER 1200 C* 17 1 g C* 200 BAGIN BOX <br /> PANELS & BRANCH CIRCUIT PANELS: <br /> REFRIGERATOR 360 * 19 20 1 * 1200 FREEZER <br /> PANEL NAME PANEL "LL" TEN BREWER 1680 21 22 360 POINT OF SALE <br /> FEED FROM PANEL FED FROM MAIN SERVICE SW/BD "MS" <br /> • • eq. • • 0 0 o CAPUCCINO 1800 * 23 24 360 POINT OF SALE <br /> FEEDER WIRE SIZE FEEDER 4#2 \ \ \ <br /> n o o N o CRCUM 360 * 25 26 30 3000 ESPRESSO <br /> VOLTS / AMPS / PHASES 208V / 100A / 30 M W COFFEE BREWER 3000 302 <br /> 27 28 <br /> NOTES: v v v 2 29 30 <br /> N � 31 32 <br /> 1. NAMEPLATES SHALL BE CONSTRUCTED OF ENGRAVED BAKELITE — BLACK BACKGROUND <br /> WITH WHITE LETTERS. 33 34 <br /> 2. MINIMUM SIZE TO BE 1"x3". 351 36 <br /> 37 38 <br /> 3. RIVET NAMEPLATES TO ENCLOSURE. LOAD SUMMARY 39 40 <br /> 1. EXIST PANELS A & B 100A <br /> 4. FILL–IN UNDERLINED NAMES AND VALUES FOR EACH NAMEPLATE TO INSTALLED. 2. PANELS C & D 107A 1 41 142 <br /> (e) (e) 3. PANEL H 84A 19064 VA TOTAL 11988 <br /> 5. ALL DISCONNECTS, PANELS, AND CIRCUIT BREAKERS INSTALLED UNDER THIS PROJECT PANEL PANEL PANEL PANEL PANEL <br /> SHALL HAVE A NAMEPLATE AS SHOWN HERE. „B„ „A„ „C„ „D„ „H„ TOTAL 291A 0 GFI CIRCUIT BREAKER DEPEND PER 220-20 EL DORADO GAS <br /> 6. NAMEPLATES FOR EMERGENCY POWER FED EQUIPMENT SHALL HAVE RED BACKGROUND I I I I 1 <br /> 129 AMPS X .65 = 84 AMPS STATION <br /> WITH WHITE LETTERS. IMPROVEMENT <br /> PUMP EQUIPMENT <br /> (e) LOADS LOADS „ „ 1605 S. EL DORADO STREET <br /> (DOUBLE PANEL Stockton, CA. 95206 <br /> NAME PLATES/LABELS C LUGGED) LOCATION : KITCHEN TITLE 24 CATEGORY: MIXED <br /> TOTAL KVA : 5.5 CONNECT AMPS: 23A <br /> SCALE: N.T.S. E6 ONE LINE DIAGRAM A MOUNTING FLUSH VOLTAGE 120/240V 10 3W LIST OF CONSULTANTS <br /> 32" 0� BUSSING 225A E] MCB ® MLO FEEDER ® SEE ONE LINE DIAGRAM <br /> SCALE: N.T.S. E6 ARCHITECTURAL <br /> rlWOOD STUDS AT 16" O.C. AIC 22,000 AIC ❑ EXISTING n n--*— <br /> DESCRIPTION LOAD BRKR BRKR LOAD DESCRIPTION APEX ARCHITECTURE <br /> 845 S. COMMERCE STREET <br /> x I° OUTLETS 360 20/1 1 2 20/1 400 WALKIN LIGHTS STOCKTON, CA 95206 <br /> 540 3 4 1 360 ROOF OUTLETS (209)662-4874 <br /> PROVIDE 1/8" THICK STEEL PLATE 720 * 5 6 864 AIR WATER ARCHITECT: STEVEN A apexplanning@hotTOIRRES II <br /> BACKING AND ATTACH IT TO WOOD <br /> LO I I I STUD USING #12X2" WOOD SCREWS. HOOD LIGHTS/CONTROL 400 40/1 * 7 g <br /> MINIMUM OF (2) PLACES. FIRE SUPPRESSION 200 20/1 9 10 <br /> SPARE 11 12 ACS . <br /> �° x lel x le 4"C-4#500MCM 13 14 Engineerm <br /> Tt RISER AND WEATHER HEAD STRAPPED TO BUILDING 15 16 50 years <br /> ATTACH PANEL TO STEEL BACKING 17 18 4512 Feather River Or#F,Stockton,CA 95219 <br /> USING 5/16" THREADED BOLTS. 19 201 209-478-8270 I www.hcs-eng.com <br /> CUT THREAD INTO BACKING. '' <br /> MINIMUM OF (6) PLACES. ,y�j� 21 22 In Richard C.Smith,PE richard@hcs-eng.com <br /> 23 24 13 Bhupendra Patel,PE bhupendra@hcs-eng.com <br /> MOUNTING DETAIL: SURFACE PANELKD \� 26" 36" 25 26 13 Elizabeth Aguilar elizabeth@hcs-eng com <br /> 271 28 PROJECT#2019.285 <br /> SCALE: N.T.S. E6 29 30 <br /> WALK–IN LIGHTS 400 20/1 31 32 PROFESS/ON <br /> q <br /> PANEL INT LIGHTS 1070 33 34 0 c. S� � <br /> 0 <br /> WALL O EXT LIGHTS 150 35 36 No. E14303 �y � <br /> 37 38 Exp. 6-30-21 <br /> 208V, 240V SYSTEM 39 40 ��E oP� <br /> (42" FOR 480V SYSTEM) 41 42 9TFOF ca�Fo�� <br /> 36" DEDICATED, CLEAR, UNOBSTRUCTED 90» 3840 VA TOTAL 1624 <br /> WORKING SPACE IN FRONT OF PANEL 0 GFI CIRCUIT BREAKER <br /> AND FUSED DISCONNECT, FLOOR TO <br /> STRUCTURAL MEMBER ABOVE PER C.E.C. PLAN REVIEW ACCEPTANCE <br /> 110.26 & ARTICLE 408. VERIFY ALL 6-3/4" MIN. EDGE <br /> " POSSIBLE CONFLICTS WITH OTHER TRADES DISTANCE BOTH WAYS. <br /> 15 15 PRIOR TO ROUGHING IN THE PANELBOARD. TYPICAL AT EACH „H„ Aug 04 2020 <br /> 6” CONCRETE PAD WITH MAIN CORNER. PANEL <br /> #4 REBAR BOTH WAYS, LOCATION BACK TITLE 24 CATEGORY: HVAC WEST COAST CODE CONSULTANTS <br /> PAN E L B OAR D CLEAR 12" O.C., 3" FROM TOP DIST. FINISHED <br /> TOTAL KVA : 34.9 CONNECT AMPS: 84A <br /> SECT. GRADE MOUNTING : FLUSH VOLTAGE : 120/240V 30 4W ONE LINE DIAGRAM, <br /> WORKING SPACEKt . � . - . - . - . : : : : ❑ <br /> BUSSING 150A MCB MLO FEEDER SEE ONE LINE DIAGRAM PANEL SCHEDULES <br /> I� � � �i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i�i��i�� � AIC 18,000 AIC ❑ EX I STI N G <br /> SCALE: N.T.S. AND ELECTRICAL <br /> SIMILAR FOR FUSED DISCONNECTS E6 DESCRIPTION LOAD BRKR BRKR LOAD DESCRIPTION <br /> 50 1 A 2 15 DETAILS <br /> MAIN SERVICE SWITCHBOARD "MS" B RTU-1 9000 3 B 4 1512 KHF-1 <br /> 5 C 6 3 <br /> SCALE: N.T.S. E6 3 <br /> GRD BUS 30 7 A 8 15 <br /> MAIN SERVICE "MS" NOTES: MAIN SERVICE SWITCHBOARD "MS" RTU-2 7452 9 B 10 1512 MAU-1 <br /> 1 . ALL DIMENSIONS ARE NOMINAL. 3 11 C 12 3 <br /> — — — — — — HOOD LIGHTS 400 20/1 13 A 14 60 <br /> #1/0 BC GROUNDING CONDUCTOR 2. THE COMPLETE SWITCHBOARD SHALL HAVE A SYMMETRICAL SHORT CIRCUIT RATING STINGER 15 B 16 8532 RCU-1 <br /> TIED TO NEAREST METALLIC EQUAL TO OR GREATER THAN THAT AVAILABLE FROM THE UTILITY COMPANY. ANSUL 200 20/1 17 C 18 3 <br /> WATPER250-52(A)(1).E CEC R PIPE HERE AALALE) WH IGNITER 100 20/1 19 A 20 20 3000 DEFROST 08-32 <br /> 3. MINIMUM INTEGRAL A.I.C. RATING OF SWITCHBOARD AND FEEDER CIRCUIT <br /> BREAKERS TO BE 22,000 AMPS. STINGER 21 B 22 2 PROJECT: <br /> 4. BOLT SECTIONS OF THE SWITCHBOARD TOGETHER WITH 1/2" BOLT AND NUTS HOOD CONTROLS 200 20/1 23 C 24 20 3000 DEFROST 10/16/2019 <br /> #1/0 BC GROUNDING AT 4 PLACES PER SECTION. THESE PLANS ARE SUBJECT SPARE 20/1 25 A 26 2 <br /> CONDUCTOR 5. BOLT EACH SECTION OF SWITCHBOARD TO PAD WITH 4 1/2" A36 ROD ONE TO FIELD APPROVAL 27 B 28 <br /> AT EACH CORNER WITH 4" MINIMUM EMBEDMENT INTO FLOOR SLAB. USE 29 C 30 <br /> 10'x5/8" COPPERWELD GROUND HILTI HY150 ADHESIVE. TENSION TEST = 6000 Ibs. IF THESE PLANS ARE NOT ON THE JOB 311A 32 REV.# DATEISSUED DESCRIPTION <br /> ELECTRODE DRIVEN IN EARTH PER 33 B 34 11/20/19 PLAN CHECK <br /> 20 FT. OF #4 BC CONDUCTOR CEC 250-52(A)(5). LOCATE GROUND 6. PROVIDE SWITCHBOARD DRAWINGS TO UTILITY COMPANY FOR APPROVAL PRIOR SITE NO INSPECTIONS WILL BE MADE <br /> LAID WITHIN CONCRETE PAD OF ROD WITHIN FOOTPRINT OF TO ORDERING. 35 C 36 <br /> SWITCHBOARD WITH A MINIMUM SWITCHBOARD <br /> OF 2 CONCRETE COVER. PER 37 A 38 <br /> CEC 250.52(A)(3). 7. SWITCHBOARD TO BE SQUARE D TYPE SPEED D WITH I LINE OR APPROVED EQUAL. 139.B 40 <br /> REV= 1 41C42 <br /> GROUNDING DETAIL: 17352 VA TOTAL 117556 <br /> PROVIDE LABEL "B" IS STINGER LEG E 6 <br /> MAIN SERVICE SWITCHBOARD "MS" CITY OF STO C KTO N <br /> F <br /> SCALE: N.T.S. E6 <br /> APPROVED PLANS <br /> By:dhenry Date:08/06/2020 Copyright APEX <br /> K:\2019\201-300\2019.285 APEX El Dorado Convenience Gas Station Improvement\E6.dwg 11-20-19 09:27:21 AM richard <br />