1 5 MECHANICAL REVISED FLOOR PLAN NOTES <br /> El 16"0 EA DUCT FROM KH-1 THRU ROOF TO KHF-1 ABOVE, APEX <br /> Ifl12"0 SA DUCT DROP FROM 20x10 SA DUCT DROP <br /> BALANCE TOTAL PLENUM AIRFLOW TO 2138 CFM. T❑ KH-1 PLENUM, ARCHITECTURE <br /> 8x8 8 ---- ------- ---- - 10.0 12' '0 3, 6"� EA DUCT THRU R❑❑F PER DETAIL 5/M0, 845 S. Commerce Street <br /> ---____ _ _ _ ® (2)8"0 COMBUSTION AIR INTAKE DUCTS THRU ROOF PER DETAIL Stockton, CA. 95206 <br /> O �� 5/M0, TERMINATE C1)DUCT 12"AFF AND C1)DUCT 12"BFC, (209) 662-4874 <br /> 200 CFM �•� ___ apexplanning@hotmail.com <br /> - CS-4A 4"0 FLUE FR❑M WH- THRU R❑❑F PER DETAIL 6/M0, <br /> 200 CFM 6'0 200 C FM 200 CFM 10x10 300 CFM <br /> ® Cs-'4A CS-4 lox10 o - © REFRIGERANT LINES SIZED PER MANUFACTURER'S RECOMMENDATIONS <br /> lox o 0 1ox10 14,E 1ox10L 300 c M 875 L;Fmx 350 CFM --\ O AND 3/4" C❑NDUIT THRU R❑❑F PER DETAIL 4/M0, Steven Anthony Torres II <br /> ® ® � CS-4 CR-1 - Architect # C32553 <br /> ® --- - 7 . loo a x 0�900 CF 8""0 SA DUCT TO CS-4A, <br /> 6'o �A 410 R-1 <br /> 20 — TU-2 2x22 O <br /> 10x10 <br /> 2 2 8x 14'0 14" ' <br /> 0350 C-11-11 <br /> 35 CFM r — , CS-4 350 C M <br /> 1 x CS 4 O O <br /> ® 450 CF 300 CFM U-1 ---J <br /> CR-1 CS-4 <br /> 3 22x22 _P2x12 2x16 10•� <br /> ALL EXISTING MECHANICAL EQUIPMENT AND <br /> 10'0 12' __-- RFC-lA � DUCTWORK TO BE DEM❑'D AND REMOVED OFFSITE <br /> O O CONTRACTOR TO COORDINATE ALL FRAMING FOR <br /> HVAC EQUIPMENT AND DUCTWORK IN FIELD <br /> O O <br /> EL DORADO GAS <br /> 1 2 3 4 5 STATION <br /> 1 MECHANICAL REVISED FLOOR PLAN IMPROVEMENT <br /> 1605 S. EL DORADO STREET <br /> SCALE: 1/4" = 1'-0° AIR BALANCE Stockton, CA. 95206 <br /> TABLE <br /> TAG AIRFL❑W <br /> RTU-1 225 <br /> RTU-2 150 <br /> MAU-1 2138 <br /> TOTAL OUTSIDE AIR 2513 <br /> KHF-1 2250 <br /> CEF-1 100 <br /> CEF-1 100 <br /> TOTAL EXHAUST AIR 2450 <br /> PLAN REVIEW ACCEPTANCE <br /> Aug 04 2020 <br /> WEST COAST CODE CONSULTANTS <br /> 1 / \ 5 MECHANICAL REVISED ROOF PLAN NOTES <br /> / \ KEEP ALL EA TERMINATI❑NS, PLUMBING VENTS, FLUES, ETC, <br /> 10'-0" AWAY FROM ALL OSA INTAKES, <br /> — 2❑' 6"0 EA DUCT THRU ROOF PER DETAIL 5/M0, <br /> 0 0® ❑3 / \ • j (2)8"0 COMBUSTION AIR INTAKE DUCTS THRU ROOF PER <br /> / \ \ DETAIL 5/M0, <br /> 01fl ® 4"0 FLUE FROM WH- THRU ROOF PER DETAIL 6/M0, <br /> / REFRIGERANT LINES SIZED PER MANUFACTURER'S <br /> \ RECOMMENDATI❑NS AND 3/4" C❑NDUIT THRU ROOF PER <br /> DETAIL 4/M0, <br /> F1-1 <br /> MAU-1O RTU-1 <br /> ® 34 TALL 37'TALL RTU-2 41,5'TALL ❑5 <br /> RCU-1 <br /> \ / 4L5'TALL <br /> O❑2 / MECHANICAL REVISED FLOOR <br /> 5'-0• MIN, AND ROOF PLANS <br /> 4'-0' MIN, <br /> ALL EXISTING MECHANICAL EQUIPMENT AND <br /> 4'-0' MIN, / 4'-0' MIN, DUCTWORK TO BE DEM❑'D AND REMOVED OFFSITE C�S\ONAL FN <br /> CONT <br /> EQUIPMENT COORDINATE <br /> DUCTWORK FRAMING <br /> IN FIELD <br /> �1 <br /> L7�j� <br /> '--N0. M29759'' <br /> lf1 REN. 6-30-20' Q <br /> 9� Q ANUG\ � <br /> OF C N� <br /> O O ® ® O APEX 08-32 <br /> PROJECT: <br /> 1 MECHANICAL REVISED ROOF PLAN TfT <br /> E PLANS ARE SUBJECT DATE 1/29/2020 <br /> SCALE: 1/4" = 1'-0° O FIELD APPROVAL <br /> IF THESE PLANS ARE NOT ON THE JOB REV.# DATE ISSUED DESCRIPTION <br /> SITE NO INSPECTIONS WILL BE MADE 0 <br /> JOB # 2019-105 <br /> REV= 1 GDMD ENGINEERING, INC <br /> Mechanical and Safety Engineers <br /> 212 W Pine St, Ste 4 M 1 <br /> CITY OF STOCKTON Lodi, Ca 95242 <br /> Ph 209-367-0899 <br /> APPROVED PLANS Fax 209-367-0898 <br /> By:dhenry Date:08/06/2020 E-mail:gdmdengrinc@sbcglobal.net Copyright APEX <br />