Laserfiche WebLink
REVISIONS BY <br /> 1 2 IRRIGATION LEGEND IRRIGATION NOTES 11'25'19 JW <br /> 6.2 1" 10.0 1" SECOND STREET <br /> ■ RAINBIRD RWS-M-B-C-1401 ROOT WATERING ASSEMBLY 1. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LOCAL <br /> 0 PEPCO OCT816 OCTABUBBLER CODES AND ORDINANCES WHICH APPLY TO THE CITY OF STOCKTON. <br /> ® PEPCO QB2-16 QUADRABUBBLER 2. THE IRRIGATION CONTRACTOR SHALL INSPECT THE SITE AND BE <br /> FAMILIAR WITH ALL EXISTING SITE CONDITIONS PRIOR TO SUBMITTING <br /> IRRIGATION POINT OF CONNECTION • RAINBIRD BV050SS BALL VALVE (MANUAL FLUSH VALVE) A BID. THE IRRIGATION CONTRACTOR SHALL REVIEW RELATED DRAWINGS <br /> AND SHALL ENSURE COORDINATION WITH ALL APPLICABLE TRADES PRIOR <br /> t� RAINBIRD PEB REMOTE CONTROL VALVE, SEE PLAN FOR SIZE. TO SUBMITTING A BID. THE IRRIGATION CONTRACTOR SHALL COORDINATE HIS <br /> WORK WITH THE GENERAL CONTRACTOR AND OTHER SUBCONTRACTORS FOR LJJ <br /> THE LOCATION AND THE INSTALLATION OF SLEEVES THROUGH WALLS, } U <br /> ® RAINBIRD PEB REMOTE CONTROL VALVE W/RAINBIRD RBY SERIES WYE FILTER, SEE PLAN FOR SIZE. UNDER ROADWAYS, PAVING, STRUCTURES, ETC. <br /> 3. THIS PLAN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN <br /> PAVED AREAS IS FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED <br /> FEBCO 825Y-1 1/4", REDUCED PRESSURE BACKFLOW PREVENTION DEVICE IN PLANTING AREAS WHERE POSSIBLE. AVOID ANY CONFLICTS BETWEEN THE Q � LU <br /> W/WEATHERGUARD BLANKET SPRINKLER SYSTEM, AND PLANTING AND ARCHITECTURAL FEATURES. c CD X u, <br /> cn <br /> B 4. DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS SHOWN ON THE DRAWINGS Q) N m <br /> HUNTER FLOW CLIK FLOW SENSOR WITH FCT-150 RECEPTACLE TEE <br /> WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS AND GRADE DIFFERENCES Q � ILL m z <br /> IN THE AREA EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. M Q .o CD C ,U <br /> SUCH OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF E U 0 � _ <br /> 0 �� I REAL Q - - - - - - - i ® MASTER VALVE RAINBIRD PEB 1" THE OWNER'S AUTHORIZED REPRESENTATIVE. IN THE EVENT THAT THIS NOTIFICATION q - � o Q (� <br /> • T VEN CO2 nN I I ENDIN IS NOT PERFORMED, THE IRRIGATION CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY Q Ln N W <br /> • :3 <br /> r I ►/ NIBCO T-580 BALL VALVE - LINE SIZE FOR ANY REVISIONS NECESSARY. Ol co_ Q <br /> 5. ELECTRICAL CONTRACTOR TO SUPPLY 120 VOLT A.C. (2.5 AMP) SERVICE (N v o` o` <br /> r I RAINBIRD ESP4SMTE INDOOR MODULAR IRRIGATION CONTROLLER 0 Q o o <br /> • KITTEN TO CONTROLLER LOCATIONS. IRRIGATION CONTRACTOR TO MAKE FINAL N N Q <br /> U I © INSTALL IN PUMP CONTROL ROOM. CONTROLLER SHALL BE EQUIPPED WITH N N <br /> I EXISTING ° 112 RETAIL CONNECTIONS FROM ELECTRICAL STUB-OUTS TO CONTROLLERS <br /> 61 RETAIL r I RAINBIRD RSD-BEx RAIN SENSOR AND RAINBIRD MS-100 SOIL MOISTURE SENSOR z <br /> ° ' WALK-IN I 6. EACH CONTROLLER SHALL HAVE IT'S OWN INDEPENDENT GROUND WIRE. Q <br /> STORM CASHIER P RETAIL �1 W EXISTING 1" WATER METER 7. SPLICING OF ANY WIRES WILL NOT BE PERMITTED EXCEPT IN VALVE BOXES. <br /> DRAIN ° r � o s dP r-' REFRIGERATOP, <br /> E asP% 114 115 I LEAVE A 24" COIL OF EXCESS WIRE AT EACH SPLICE AND 100 FEET ON CENTER W <br /> JEXIOAT <br /> ALONG WIRE RUN. TAPE WIRE IN BUNDLES 10 FEET ON CENTER. NO TAPING <br /> RETAIL I SCH. 40 PVC SLEEVE, TWICE THE SIZE OF THE PIPE PERMITTED INSIDE SLEEVES. ALL WIRE SHALL BE U.L. APPROVED FOR DIRECT W D <br /> 6S R O � - - SCH. 40 PVC MAINLINE, 2" ( W/ 18' COVER ) BURIAL, COPPER AWG-UF 600 VOLT #14 (MIN.). USE ONLY PACKAGED APPROVED <br /> O i1 ir WIRE CONNECTORS. CLRP oD I � I I I I FACILITATE RUNNING OF IRRIGATION WIRES.RETAIL TRETIME _1 - - - - - - I I I I NOTE: DUE TO LONG RUNS OF PIPEANDLOW CITY OF STOCKTON WATER PRESSURE 8. INSTALL (1) SPARE CONTROL WIRE OF A DIFFERENT COLOR ALONG THE ENTIRE LJJ <br /> e I I I I ALL LATERALS SHALL BE 1 MINIMUM. NO 3/4 PIPE SHALL BE USED. MAIN LINE. LOOP 36" EXCESS WIRE INTO EACH SINGLE VALVE BOX AND INTO ONE Q ~ <br /> I i AIR/WATER I I I I VALVE BOX IN EACH GROUP OF VALVES. EXTRA WIRE SHALL NOT MATCH OTHER t , U <br /> I ' IIII CL 200 PVC LATERAL LINE, 1' ( W/ 12' COVER ) WIRE COLORS. SPARE WIRES SHALL BE LABELED AS SUCH. ALL WIRES SHALL BE V <br /> IIII LABELED AT THE CLOCK WITH STATION NUMBERS. COMMON WIRE SHALL BE WHITE, <br /> o 0 0 0 0 0 0 o CONTROL WIRES SHALL BE RED. <br /> I I REMOTE CONTROL VALVE IDENTIFICATION NUMBER 9. THE SPRINKLER SYSTEM IS DESIGNED TO OPERATE AT A MINIMUM OF 30 PSI. N Q <br /> I I 14 I I 1 I 1 REMOTE CONTROL VALVE SIZE THE IRRIGATION CONTRACTOR IS TO PERFORM A STATIC AND DYNAMIC PRESSURE LU <br /> I I I I I TEST, VERIFY AT LEAST 45 PSI STATIC AND RECORD THE PRESSURE READING AT Q CL <br /> EXISTING PA KING EXIS1 ING PARKING IIII 44.5 1.5" REMOTE CONTROL VALVE GPM 10 GPM. REPORT FINDINGS TO LANDSCAPE ARCHITECT. IN THE EVENT THAT THIS Q <br /> RESTRIPE F ESTRIPE IIII NOTIFICATION IS NOT PERFORMED, THE IRRIGATION CONTRACTOR SHALL ASSUME U <br /> 1 11 IIII FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY. Z U <br /> 10. INSTALL DRIP EMITTERS AT THE FOLLOWING RATES: <br /> ACCESSIBLE PARKING STALLS SEE IIII (1) PER 1 GALLON SHRUB, (2) PER 5 GALLON SHRUB Q <br /> I IIIETAIL 1/T2 FOR IMENSIONS 11. IRRIGATION CONTRACTOR TO NOTIFY ALL LOCAL JURISDICTIONS FOR INSPECTION <br /> 111 i IIII AND TESTING OF BACKFLOW PREVENTION DEVICE. a <br /> 111 IIII 12. PRIOR TO TRENCHING, CALL UNDERGROUND SERVICE ALERT AT. 1-800-642-2444. J J <br /> 111 I IIII 13. NOTIFY THE LANDSCAPE ARCHITECT OF ANY ASPECTS OF LAYOUT WHICH WILL PROVIDE <br /> INCOMPLETE OR INSUFFICIENT WATER COVERAGE OF PLANT MATERIAL. DO NOT PROCEED <br /> I I� I IIII UNTIL THE LANDSCAPE ARCHITECTS INSTRUCTIONS ARE OBTAINED. <br /> I I 14. LOCATE ALL BUBBLERS ON UPHILL SIDE OF TREES AND SHRUBS. <br /> I� I IIII WATER USE CALCULATION <br /> 15 WE LDS S SEALAN <br /> BET CUT U RE OAN-HARDENING AND ND PRIMER S ALLL BE M SEDBLE WITH PIPE. ALL PVC <br /> 111 I r - - - - - - - - - - - - - - - - - - - - - - - - - - IIII 16. CONTRACTOR SHALL GUARANTEE THE IRRIGATION SYSTEM FOR A PERIOD OF (1) YEAR <br /> 111 I I I 111 1 AFTER DATE OF FINAL ACCEPTANCE. <br /> 111 I I I IIII 17. CONTRACTOR SHALL ENSURE THAT SLEEVES UNDER PAVEMENT ARE MARKED AT CURB, <br /> M A WA = (49.1 )(0.62)(0.45 X 1 ,132) TO AID IN LOCATING THEM.18. GENERAL CONTRACTOR SHALL STUB 2" CONDUIT THROUGH WALLS/FOUNDATIONS TO <br /> FACILITATE RUNNING OF IRRIGATION WIRES. <br /> I I M AWA = 15,507.15 GALLONS PER YEAR 19. AN IRRIGATION AUDIT SHALL BE CONDUCTED AT THE COMPLETION OF IRRIGATION <br /> I I SYSTEM INSTALLATION, AND SHALL BE PROVIDED TO THE CITY OF STOCKTON COMMUNITY <br /> I (E)UNDERGROUND I DEVELOPMENT DEPARTMENT, BY THE PROJECT LANDSCAPE ARCHITECT. THE AUDIT SHALL <br /> I FUEL TANK I INCLUDE ALL REQUIREMENTS AS NOTED IN SECTION 492.12 OF THE MODEL WATER <br /> (E)POWER I I EFFICIENT LANDSCAPE ORDINANCE. NOTE: ALL IRRIGATION AUDITS SHALL BE CONDUCTED <br /> POLE L - - - - - - - - - - - - - - - - - - - - - - - - - J BY A CERTIFIED LANDSCAPE IRRIGATION AUDITOR. <br /> r-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- - - W SNo. 533 <br /> C��`�P <br /> I I <br /> 0 ESTIMATED TOTAL WATER USE JustinNOWare� 1 <br /> Sign ture <br /> I I <br /> I I <br /> I I O 2/28/20 <br /> I I Q Expiration Date <br /> Q REFERENCE EVAPOTRANSPIRATION (ETo): 49.1 !' Dated <br /> ( ) I AGE I I E)SI Q PLANT ESTIMATED ��� 0 A1����4 <br /> (f� IRRIGATION IRRIGATION ETAF LANDSCAPE ETAF X F C <br /> I Q HYDROZONE FACTOR METHOD EFFICIENCY (IE) (PF/IE) AREA (SF) AREA TOTAL WATER <br /> I I <br /> W (PF) USE (ETWU) <br /> zi CANOPY ABOVE i LOW:TREES 0.2 DRIP 0.81 0.2469 80 19.75 601.23 W <br /> m I I <br /> L-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -J LOW: <br /> (n SHRUB BEDS <br /> 0.3 DRIP 0.81 0.3704 1,052 389.66 11,862.03 <br /> �J TOTALS: 1,132 409.41 12,463.26 w w <br /> SCOPE OF WORK HYDROZONE <br /> LIMITED TO INTERIOR INFORMATION TABLE <br /> �y <br /> REMODEL & NEW �I <br /> LANDSCAPING. NO <br /> ADDITIONAL SITE WORK HYDROZONE VALVES IRRIGATION METHOD AREA % OF LANDSCAPE AREA <br /> CLIENT <br /> � <br /> LOW DRIP 80 SF 7.06 PROPOSED (TREES) 2 <br /> LOW 1 DRIP I 1,052 SF 92.94(SHRUB BEDS) �-+ <br /> 11N j� TOTAL: 1,132 SF 0 <br /> NOTE: 1,132 SF OF LANDSCAPE AREA NOTED ABOVE AND USED IN CALCULATIONS ABOVE <br /> REPRESENTS ALL LANDSCAPE AREA AT A REDEVELOPED SITE <br /> X111 1 STANDARD VALVE BOX SHEET TITLE <br /> FINISH GRADE <br /> 11 1 0 0 <br /> 1 III O / /ISTI / / MIN. 18/2 WIRE TO INTERFACE PANEL. <br /> I 1 I1 1 <br /> EXISTING O STC/ DR MAXIMUM WIRE DISTANCE RUN OF 1,000'BOLLAR0 <br /> II (EXISTING �,, O REMAIN / /0 / / O O O FLOW-CUK r l <br /> kM DRAIN j�l �XIST EOGDEE / �.J FCT-150 RECEPTACLE IEE <br /> ® THESE PLANS ARE SUBJECT MAIN UNE PIPE Q O O <br /> TO FIELD APPROVAL Q <br /> � Ow � <br /> IF THESE PLANS ARE NOT ON THE JOB <br /> SITE NO INSPECTIONS WILL BE MADE To /RRIG00N VALVES Q o <br /> WATER PURVEYOR INFORMATION w ~' <br /> PROJECT WATER PURVEYOR IS CALIFORNIA REV= l PROJECT <br /> WATER SERVICE COMPANY 209 464-8311 *NOTES INLET PIPE LEHGTH OF SENSOR MUST BE MIN. fOX PIPE DA SIRNGHT, <br /> PLAN REVIEW ACCEPTANCE DATE 7/10/19 <br /> CLEAN RUN OF PIPE, NO FITTINGS OR TURNS OUTLET PIPE LENGTH OF SENSOR <br /> WATER USED ONSITE SHALL BE FROM A CITY OF STOCKTON MUST BE MIN. 5X PIPE OR. OF STRAIGIH CLEAN RUN OF PIPE, NO FITTINGS OR (URNS. Aug 04 2020 SCALE 1"=101 <br /> POTABLE WATER SOURCE APPROVED PLANS DRAWN JW <br /> CALIFORNIA WATER HAS CONFIRMED A STATIC <br /> By:dhenry Date:08/06/2020 NOT TO SCAI,� WEST COAST CODE CONSULTANTS SHEET L2 <br /> WATER PRESSURE OF 50 PSI ONSITE <br /> OF 3 SHEETS <br />