My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2021 8:50:52 AM
Creation date
3/25/2021 8:52:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LIQUID SENSOR SETUP -- OUTPUT RELAY SETUP <br /> FLOAT S I ZE: 4.0 I N. - - - - - - - - - - - - - - - - - - - - - - - - <br /> WATER WARNINI= 2.0 L 1 :87 STP R 1 :87 STP <br /> HIGH WATER LIMIT: 2.5 TRI-STATE (SINGLE FLOAT) TYPE: <br /> WATER ALARM FILTER: LOW CATEGORY : STP SUMP STANDARD <br /> NORMALLY CLOSED <br /> MAX OR LABEL VOL: 12032 L 2:91 STP TANK #: 1 <br /> OVERFILL LIMIT 90% <br /> 10828 TRI-STATE (SINGLE FLOAT) <br /> CATEGORY <br /> HIGH PRODUCT 95% STP SUMP <br /> 11430 LIQUID SENSOR ALMS <br /> DELIVERY LIMIT 15% L 1 :FUEL ALARM <br /> 1804 L 3:DSL STP L 7:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L 8:FUEL ALARM <br /> LOW PRODUCT 400 CATEGORY : STP SUMP L 9:FUEL ALARM <br /> LEAK ALARM LIIiIT: 99 L10:FUEL ALARM <br /> SUDDEN LOSS LIMIT: 99 L 1 :SENSOR OUT ALARM <br /> TANK TILT 0.00 L 4:87ANNULAR L 7:SENSOR OUT ALARM <br /> PROBE OFFSET 0.00 DUAL POINT HYDROSTATIC L 8:SENSOR OUT ALARM <br /> CATEGORY : ANNULAR SPACE L 9:SENSOR OUT ALARM <br /> L10:SENSOR OUT ALARM <br /> SIPHON MANIFOLDED TANKS L 1 :SHORT ALARM <br /> T#: N014E L 7:SHORT ALARM <br /> LINE MANIFOLDED TANKS L 5:91 ANNULAR L 8:SHORT ALARM <br /> T#: NONE DUAL POINT HYDROSTATIC L 9:SHORT ALARM <br /> CATEGORY : ANNULAR SPACE L1O:SHORT ALARM <br /> LEAK MIN PERIODIC:: O% ISD SITE ALARMS <br /> 0 ISD GROSS PRES FAIL <br /> L 6:DSL ANNULAR ISD DEGRD PRES FAIL <br /> LEAK MIN ANNUAL 0% TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL <br /> 0 CATEGORY : ANNULAR SPACE ISD VP PRES FAIL <br /> ISD VP STATUS FAIL <br /> MISSING RELAY SETUP <br /> PERIODIC. TEST TYPE MISSING HOSE SETUP <br /> STANDARD L 7:DISP 1-2 MISSING TANK SETUP <br /> TRI-STATE (SINGLE FLOAT) MISS VAPOR FLOW MTR <br /> ANNUAL TEST FAIL CATEGORY : DISPENSER PAN MISS VAPOR PRES SEN <br /> ALARM DISABLED MISSING VP INPUT <br /> ISD SETUP FAIL <br /> PERIODIC TEST FAIL ISD SENSOR OUT FAIL <br /> ALARM DISABLED L 8:DISP 3-4 <br /> TRI-STATE (SINGLE FLOAT) ISD HOSE ALARMS <br /> GROSS TEST FAIL CATEGORY : DISPENSER PAN ALL:GROSS COLLECT FAIL <br /> ALARM DISABLED ALL:DEGRD COLLECT FAIL <br /> ANN TEST AVERAGING: OFF ALL:FLOW COLLECT FAIL <br /> PER TEST AVERHGING: OFF L 9:DISP 5-6 ALL:AIRFLOW MTR SETUP <br /> TRI-STATE (SINGLE FLOAT) <br /> TANK TEST NOTIFY: OFF CATEGORY : DISPENSER PAN R 2:91 STP <br /> TYPE: <br /> TNK TST SIPHON BREAK OFF STANDARD <br /> DELIVERY DELAY 3 MIN LIO:DISP 7-8 NORMALLY CLOSED <br /> STICK OFFSET 0.00 TRI-STATE (SINGLE FLOAT) TANK #: 2 <br /> PUMP THRESHOLD 10.00% CATEGORY DISPENSER PAN <br /> LIQUID SENSOR ALMS <br /> L 2:FUEL ALARM <br /> L11 :DISP 9-10 L 7:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L B:FUEL ALARM <br /> CATEGORY DISPENSER PAN L 9:FUEL ALARM <br /> L1O:FUEL ALARM <br /> L 2:SENSOR OUT ALARM <br /> L 7:SENSOR OUT ALARM <br /> L 8:SENSOR OUT ALARM <br /> L10:SENSOR OUT ALARM <br /> L1O:SHORT ALARM <br /> LEAK TEST METHOD <br /> - - - - - - - - - - - - ISD SITE ALARMS <br /> TEST ON DATE : ALL TANK ISIS GROSS PRES FAIL <br /> MAY 27. 2011 ISD DEGRD FRES FAIL <br /> START TIME : DISABLED ISD VAPOR LEAK FAIL <br /> TEST RATE :0.20 GAL,/HR ISD VP PRES FAIL <br /> DURATION 2 HOURS ISD VP STATUS FAIL <br /> MISSING RELAY SETUP <br /> TST EARLY STOP:DISABLED MISSING HOSE SETUP <br /> MISSING TANK SETUP <br /> LEAK TEST REPORT FORMAT MISS VAPOR FLOW MTR <br /> NORMAL MISS VAPOR PRES SEN <br /> MISSING VP INPUT <br /> ISD SETUP FAIL <br /> ISD SENSOR OUT FAIL <br />
The URL can be used to link to this page
Your browser does not support the video tag.